Methods for calculating the pressure loss of the air flow and energy consumed by the fan of the cotton harvester

The article presents the methods for calculating the pressure loss of the pneumatic transport system of a cotton harvester related to the power consumption of the fan drive. Mathematical models for computer calculation are presented. Numerical studies of the influence of the pipeline diameter and th...

Full description

Bibliographic Details
Main Authors: Matchanov Rafik, Rizaev Anvar, Yuldashev A, Kuldoshev Davronbek, Mirzaeva M
Format: Article
Language:English
Published: EDP Sciences 2021-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/40/e3sconf_conmechydro2021_04011.pdf
id doaj-1065bf814b094897840cbaaa1d89e385
record_format Article
spelling doaj-1065bf814b094897840cbaaa1d89e3852021-06-11T07:16:39ZengEDP SciencesE3S Web of Conferences2267-12422021-01-012640401110.1051/e3sconf/202126404011e3sconf_conmechydro2021_04011Methods for calculating the pressure loss of the air flow and energy consumed by the fan of the cotton harvesterMatchanov Rafik0Rizaev Anvar1Yuldashev A2Kuldoshev Davronbek3Mirzaeva M4JV “Agrikhim”LLCInstitute of Mechanics and Seismic Stability of Structures of the Academy of Sciences of the Republic of UzbekistanInstitute of Mechanics and Seismic Stability of Structures of the Academy of Sciences of the Republic of UzbekistanInstitute of Mechanics and Seismic Stability of Structures of the Academy of Sciences of the Republic of UzbekistanInstitute of Mechanics and Seismic Stability of Structures of the Academy of Sciences of the Republic of UzbekistanThe article presents the methods for calculating the pressure loss of the pneumatic transport system of a cotton harvester related to the power consumption of the fan drive. Mathematical models for computer calculation are presented. Numerical studies of the influence of the pipeline diameter and the air mixture composition on the power consumption of the fan drive are presented. It was determined that with an increase in the diameter of the pipeline from 0.15 m to 0.175 m and a change in the mixture concentration μ = 0.228 ÷ 0.338 for a serial receiving chamber, the fan drive power decreases from 10.3 kW to 5.79 kW.https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/40/e3sconf_conmechydro2021_04011.pdf
collection DOAJ
language English
format Article
sources DOAJ
author Matchanov Rafik
Rizaev Anvar
Yuldashev A
Kuldoshev Davronbek
Mirzaeva M
spellingShingle Matchanov Rafik
Rizaev Anvar
Yuldashev A
Kuldoshev Davronbek
Mirzaeva M
Methods for calculating the pressure loss of the air flow and energy consumed by the fan of the cotton harvester
E3S Web of Conferences
author_facet Matchanov Rafik
Rizaev Anvar
Yuldashev A
Kuldoshev Davronbek
Mirzaeva M
author_sort Matchanov Rafik
title Methods for calculating the pressure loss of the air flow and energy consumed by the fan of the cotton harvester
title_short Methods for calculating the pressure loss of the air flow and energy consumed by the fan of the cotton harvester
title_full Methods for calculating the pressure loss of the air flow and energy consumed by the fan of the cotton harvester
title_fullStr Methods for calculating the pressure loss of the air flow and energy consumed by the fan of the cotton harvester
title_full_unstemmed Methods for calculating the pressure loss of the air flow and energy consumed by the fan of the cotton harvester
title_sort methods for calculating the pressure loss of the air flow and energy consumed by the fan of the cotton harvester
publisher EDP Sciences
series E3S Web of Conferences
issn 2267-1242
publishDate 2021-01-01
description The article presents the methods for calculating the pressure loss of the pneumatic transport system of a cotton harvester related to the power consumption of the fan drive. Mathematical models for computer calculation are presented. Numerical studies of the influence of the pipeline diameter and the air mixture composition on the power consumption of the fan drive are presented. It was determined that with an increase in the diameter of the pipeline from 0.15 m to 0.175 m and a change in the mixture concentration μ = 0.228 ÷ 0.338 for a serial receiving chamber, the fan drive power decreases from 10.3 kW to 5.79 kW.
url https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/40/e3sconf_conmechydro2021_04011.pdf
work_keys_str_mv AT matchanovrafik methodsforcalculatingthepressurelossoftheairflowandenergyconsumedbythefanofthecottonharvester
AT rizaevanvar methodsforcalculatingthepressurelossoftheairflowandenergyconsumedbythefanofthecottonharvester
AT yuldasheva methodsforcalculatingthepressurelossoftheairflowandenergyconsumedbythefanofthecottonharvester
AT kuldoshevdavronbek methodsforcalculatingthepressurelossoftheairflowandenergyconsumedbythefanofthecottonharvester
AT mirzaevam methodsforcalculatingthepressurelossoftheairflowandenergyconsumedbythefanofthecottonharvester
_version_ 1721383085766868992