Impact of lung density on the lung dose estimation for radiotherapy of breast cancer

Background and purpose: To investigate the impact of the clinical implementation of a deterministic particle transport method on the lung dose evaluation for radiotherapy of breast cancer focusing on dosimetric effects of the lung density. Material and methods: Fourteen patients with left sided brea...

Full description

Bibliographic Details
Main Authors: Emma Hedin, Anna Bäck, Roumiana Chakarova
Format: Article
Language:English
Published: Elsevier 2017-07-01
Series:Physics and Imaging in Radiation Oncology
Online Access:http://www.sciencedirect.com/science/article/pii/S2405631616300379
id doaj-103d4191a8c5404f82291fa88cfde655
record_format Article
spelling doaj-103d4191a8c5404f82291fa88cfde6552020-11-24T21:28:26ZengElsevierPhysics and Imaging in Radiation Oncology2405-63162017-07-013510Impact of lung density on the lung dose estimation for radiotherapy of breast cancerEmma Hedin0Anna Bäck1Roumiana Chakarova2Dept of Radiation Physics, Inst of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Dept of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, SwedenDept of Radiation Physics, Inst of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Dept of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, SwedenCorresponding author at: Department of Radiation Physics, Gula straket 2B, Sahlgrenska University Hospital, SE-413 45 Gothenburg, Sweden.; Dept of Radiation Physics, Inst of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Dept of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, SwedenBackground and purpose: To investigate the impact of the clinical implementation of a deterministic particle transport method on the lung dose evaluation for radiotherapy of breast cancer focusing on dosimetric effects of the lung density. Material and methods: Fourteen patients with left sided breast cancer having both deep inspiration breath hold (DIBH) and free breathing CT scans were studied. Lung density variations for 157 patients treated under DIBH were quantified and the cases with the lowest lung densities for breast and for loco regional treatment added to the study. Dose calculations were performed with the class-b type algorithm AAA and the deterministic algorithm Acuros XB. Monte Carlo method was utilized as reference. Differences in the dose distributions were evaluated by comparing DVH parameters. Results: Lung density variations between 0.08 and 0.3 g/cm3 and between 0.02 and 0.25 g/cm3 were found for loco-regional and tangential breast treatments under DIBH, respectively. Lung DVH parameters for patients with medium and high lung density obtained by the different algorithms agreed within 3%. Larger differences were observed for low lung density cases where the correction based algorithm underestimated V10Gy and overestimated V40Gy by up to 5%. The least affected parameter, V20Gy, deviated by less than 2% for all cases and densities. Conclusions: Dosimetric constrains for lung based on V20Gy required minimum changes due to implementation of the new algorithm regardless of breathing technique or type of treatment. Evaluation criteria utilizing V10Gy or V40Gy needed reconsideration, especially for treatments under DIBH involving low lung density. Keywords: Breast cancer, Lung dose, DIBH, Acuros XB, Monte Carlohttp://www.sciencedirect.com/science/article/pii/S2405631616300379
collection DOAJ
language English
format Article
sources DOAJ
author Emma Hedin
Anna Bäck
Roumiana Chakarova
spellingShingle Emma Hedin
Anna Bäck
Roumiana Chakarova
Impact of lung density on the lung dose estimation for radiotherapy of breast cancer
Physics and Imaging in Radiation Oncology
author_facet Emma Hedin
Anna Bäck
Roumiana Chakarova
author_sort Emma Hedin
title Impact of lung density on the lung dose estimation for radiotherapy of breast cancer
title_short Impact of lung density on the lung dose estimation for radiotherapy of breast cancer
title_full Impact of lung density on the lung dose estimation for radiotherapy of breast cancer
title_fullStr Impact of lung density on the lung dose estimation for radiotherapy of breast cancer
title_full_unstemmed Impact of lung density on the lung dose estimation for radiotherapy of breast cancer
title_sort impact of lung density on the lung dose estimation for radiotherapy of breast cancer
publisher Elsevier
series Physics and Imaging in Radiation Oncology
issn 2405-6316
publishDate 2017-07-01
description Background and purpose: To investigate the impact of the clinical implementation of a deterministic particle transport method on the lung dose evaluation for radiotherapy of breast cancer focusing on dosimetric effects of the lung density. Material and methods: Fourteen patients with left sided breast cancer having both deep inspiration breath hold (DIBH) and free breathing CT scans were studied. Lung density variations for 157 patients treated under DIBH were quantified and the cases with the lowest lung densities for breast and for loco regional treatment added to the study. Dose calculations were performed with the class-b type algorithm AAA and the deterministic algorithm Acuros XB. Monte Carlo method was utilized as reference. Differences in the dose distributions were evaluated by comparing DVH parameters. Results: Lung density variations between 0.08 and 0.3 g/cm3 and between 0.02 and 0.25 g/cm3 were found for loco-regional and tangential breast treatments under DIBH, respectively. Lung DVH parameters for patients with medium and high lung density obtained by the different algorithms agreed within 3%. Larger differences were observed for low lung density cases where the correction based algorithm underestimated V10Gy and overestimated V40Gy by up to 5%. The least affected parameter, V20Gy, deviated by less than 2% for all cases and densities. Conclusions: Dosimetric constrains for lung based on V20Gy required minimum changes due to implementation of the new algorithm regardless of breathing technique or type of treatment. Evaluation criteria utilizing V10Gy or V40Gy needed reconsideration, especially for treatments under DIBH involving low lung density. Keywords: Breast cancer, Lung dose, DIBH, Acuros XB, Monte Carlo
url http://www.sciencedirect.com/science/article/pii/S2405631616300379
work_keys_str_mv AT emmahedin impactoflungdensityonthelungdoseestimationforradiotherapyofbreastcancer
AT annaback impactoflungdensityonthelungdoseestimationforradiotherapyofbreastcancer
AT roumianachakarova impactoflungdensityonthelungdoseestimationforradiotherapyofbreastcancer
_version_ 1725970480685383680