Electrochemical Corrosion Behavior of Carbon Steel and Hot Dip Galvanized Steel in Simulated Concrete Solution with Different pH Values
<p>Hot dip galvanizing technology is now widely used as a method of protection for steel rebars. The corrosion behaviors of Q235 carbon steel and hot galvanized steel in a Ca(OH)<sub>2</sub> solution with a pH from 10 to 13 was investigated by electrode potential and polarization c...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Kaunas University of Technology
2017-08-01
|
Series: | Medžiagotyra |
Subjects: | |
Online Access: | http://matsc.ktu.lt/index.php/MatSc/article/view/16675 |
id |
doaj-0fb170c2ea5e41f0977a7b990678e976 |
---|---|
record_format |
Article |
spelling |
doaj-0fb170c2ea5e41f0977a7b990678e9762020-11-24T21:32:47ZengKaunas University of TechnologyMedžiagotyra1392-13202029-72892017-08-0123328028410.5755/j01.ms.23.3.166758523Electrochemical Corrosion Behavior of Carbon Steel and Hot Dip Galvanized Steel in Simulated Concrete Solution with Different pH ValuesWanchen XIE0Jiansan LI1Yali LI2South China University of TechnologySouth China University of TechnologySouth China University of Technology<p>Hot dip galvanizing technology is now widely used as a method of protection for steel rebars. The corrosion behaviors of Q235 carbon steel and hot galvanized steel in a Ca(OH)<sub>2</sub> solution with a pH from 10 to 13 was investigated by electrode potential and polarization curves testing. The results indicated that carbon steel and hot galvanized steel were all passivated in a strong alkaline solution. The electrode potential of hot dip galvanized steel was lower than that of carbon steel; thus, hot dip galvanized steel can provide very good anodic protection for carbon steel. However, when the pH value reached 12.5, a polarity reversal occurred under the condition of a certain potential. Hot dip galvanized coating became a cathode, and the corrosion of carbon steel accelerated. The electrochemical behaviors and passivation abilities of hot dip galvanized steel and carbon steel were affected by pH. The higher the pH value was, the more easily they were passivated.</p><p>DOI: <a href="http://dx.doi.org/10.5755/j01.ms.23.3.16675">http://dx.doi.org/10.5755/j01.ms.23.3.16675</a></p>http://matsc.ktu.lt/index.php/MatSc/article/view/16675carbon steel, galvanized steel, pH values, electrochemical test |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Wanchen XIE Jiansan LI Yali LI |
spellingShingle |
Wanchen XIE Jiansan LI Yali LI Electrochemical Corrosion Behavior of Carbon Steel and Hot Dip Galvanized Steel in Simulated Concrete Solution with Different pH Values Medžiagotyra carbon steel, galvanized steel, pH values, electrochemical test |
author_facet |
Wanchen XIE Jiansan LI Yali LI |
author_sort |
Wanchen XIE |
title |
Electrochemical Corrosion Behavior of Carbon Steel and Hot Dip Galvanized Steel in Simulated Concrete Solution with Different pH Values |
title_short |
Electrochemical Corrosion Behavior of Carbon Steel and Hot Dip Galvanized Steel in Simulated Concrete Solution with Different pH Values |
title_full |
Electrochemical Corrosion Behavior of Carbon Steel and Hot Dip Galvanized Steel in Simulated Concrete Solution with Different pH Values |
title_fullStr |
Electrochemical Corrosion Behavior of Carbon Steel and Hot Dip Galvanized Steel in Simulated Concrete Solution with Different pH Values |
title_full_unstemmed |
Electrochemical Corrosion Behavior of Carbon Steel and Hot Dip Galvanized Steel in Simulated Concrete Solution with Different pH Values |
title_sort |
electrochemical corrosion behavior of carbon steel and hot dip galvanized steel in simulated concrete solution with different ph values |
publisher |
Kaunas University of Technology |
series |
Medžiagotyra |
issn |
1392-1320 2029-7289 |
publishDate |
2017-08-01 |
description |
<p>Hot dip galvanizing technology is now widely used as a method of protection for steel rebars. The corrosion behaviors of Q235 carbon steel and hot galvanized steel in a Ca(OH)<sub>2</sub> solution with a pH from 10 to 13 was investigated by electrode potential and polarization curves testing. The results indicated that carbon steel and hot galvanized steel were all passivated in a strong alkaline solution. The electrode potential of hot dip galvanized steel was lower than that of carbon steel; thus, hot dip galvanized steel can provide very good anodic protection for carbon steel. However, when the pH value reached 12.5, a polarity reversal occurred under the condition of a certain potential. Hot dip galvanized coating became a cathode, and the corrosion of carbon steel accelerated. The electrochemical behaviors and passivation abilities of hot dip galvanized steel and carbon steel were affected by pH. The higher the pH value was, the more easily they were passivated.</p><p>DOI: <a href="http://dx.doi.org/10.5755/j01.ms.23.3.16675">http://dx.doi.org/10.5755/j01.ms.23.3.16675</a></p> |
topic |
carbon steel, galvanized steel, pH values, electrochemical test |
url |
http://matsc.ktu.lt/index.php/MatSc/article/view/16675 |
work_keys_str_mv |
AT wanchenxie electrochemicalcorrosionbehaviorofcarbonsteelandhotdipgalvanizedsteelinsimulatedconcretesolutionwithdifferentphvalues AT jiansanli electrochemicalcorrosionbehaviorofcarbonsteelandhotdipgalvanizedsteelinsimulatedconcretesolutionwithdifferentphvalues AT yalili electrochemicalcorrosionbehaviorofcarbonsteelandhotdipgalvanizedsteelinsimulatedconcretesolutionwithdifferentphvalues |