Intra- and Interobserver Reliability of Bone Volume Estimation Using OsiriX Software in Patients with Cleft Lip and Palate Using Cone Beam Computed Tomography
The objective of the current study was to evaluate intra- and interobserver bone volume measurements and effect of orientation on the reliability of bone volume evaluation in as-acquired vis-à-vis oriented cone beam computed tomography scans using Osirix software and possible correlation between gen...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-01-01
|
Series: | Dentistry Journal |
Subjects: | |
Online Access: | https://www.mdpi.com/2304-6767/9/2/14 |
id |
doaj-0fae40375aea4102b697da72d6d1a512 |
---|---|
record_format |
Article |
spelling |
doaj-0fae40375aea4102b697da72d6d1a5122021-01-23T00:00:57ZengMDPI AGDentistry Journal2304-67672021-01-019141410.3390/dj9020014Intra- and Interobserver Reliability of Bone Volume Estimation Using OsiriX Software in Patients with Cleft Lip and Palate Using Cone Beam Computed TomographyAnuraj Singh Kochhar0Maninder Singh Sidhu1Mona Prabhakar2Ritasha Bhasin3Gulsheen Kaur Kochhar4Himanshu Dadlani5Gianrico Spagnuolo6Viral Vijay Mehta7Former Orthodontist, Department of Dentistry, Max Hospital, Gurgaon 122001, IndiaDepartment of Orthodontics, Faculty of Dental Sciences, SGT University, Gurugram 122006, IndiaDepartment of Orthodontics, Faculty of Dental Sciences, SGT University, Gurugram 122006, IndiaFaculty of Dentistry, University of Toronto, Toronto, ON M5G 1X3, CanadaDepartment of Pediatric & Preventive Dentistry, National Dental College & Hospital, Dera Bassi 140507, IndiaDepartment of Periodontology, Kalka Dental College & Hospital, Meerut 210507, IndiaDepartment of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples “Federico II”, 80131 Naples, ItalyFaculty of Dentistry, University of Toronto, Toronto, ON M5G 1X3, CanadaThe objective of the current study was to evaluate intra- and interobserver bone volume measurements and effect of orientation on the reliability of bone volume evaluation in as-acquired vis-à-vis oriented cone beam computed tomography scans using Osirix software and possible correlation between gender, age, and bone volume required. For this, 31 cone beam computed tomography (CBCT) scans of 14 girls and 17 boys (aged 9–13) with unilateral cleft lip and/or palate who met the inclusion criteria were analyzed. Efficacy and reliability of third party software Osirix for bone volume calculation was assessed using as acquired and oriented volumes by three specialists (a radiologist, an orthodontist, and an oral maxillofacial surgeon). The dataset and readings were anonymized to prevent any bias. Two-way mixed model analysis on as-acquired and oriented observations exhibited intra-class coefficient (ICC) values ≥ 0.90. Wilcoxon signed rank test (<i>p</i> = 0.10) and Kruskal–Wallis ANOVA (<i>p</i> = 0.46) indicated that although a clinical difference in volume assessment was seen between as-acquired and oriented observations (inter-observer and intra-observer), it was statistically insignificant. Spearman’s bi-variate correlation analysis revealed a significant relation between the type (side) of cleft and bone volume required to fill the defect (<i>p</i> < 0.05). Although there was clinical difference in bone volume measurement by the three observers, it was insignificant statistically. Clefts on the left side in the patients had significantly more bone required than the right side, whereas age and gender had no relation with bone needed to fill the defect. OsiriX software provided good reliability in measurements of bone volume.https://www.mdpi.com/2304-6767/9/2/14cleft lip and palateunilateral cleftCBCTOsirixbone volume calculationSABG |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Anuraj Singh Kochhar Maninder Singh Sidhu Mona Prabhakar Ritasha Bhasin Gulsheen Kaur Kochhar Himanshu Dadlani Gianrico Spagnuolo Viral Vijay Mehta |
spellingShingle |
Anuraj Singh Kochhar Maninder Singh Sidhu Mona Prabhakar Ritasha Bhasin Gulsheen Kaur Kochhar Himanshu Dadlani Gianrico Spagnuolo Viral Vijay Mehta Intra- and Interobserver Reliability of Bone Volume Estimation Using OsiriX Software in Patients with Cleft Lip and Palate Using Cone Beam Computed Tomography Dentistry Journal cleft lip and palate unilateral cleft CBCT Osirix bone volume calculation SABG |
author_facet |
Anuraj Singh Kochhar Maninder Singh Sidhu Mona Prabhakar Ritasha Bhasin Gulsheen Kaur Kochhar Himanshu Dadlani Gianrico Spagnuolo Viral Vijay Mehta |
author_sort |
Anuraj Singh Kochhar |
title |
Intra- and Interobserver Reliability of Bone Volume Estimation Using OsiriX Software in Patients with Cleft Lip and Palate Using Cone Beam Computed Tomography |
title_short |
Intra- and Interobserver Reliability of Bone Volume Estimation Using OsiriX Software in Patients with Cleft Lip and Palate Using Cone Beam Computed Tomography |
title_full |
Intra- and Interobserver Reliability of Bone Volume Estimation Using OsiriX Software in Patients with Cleft Lip and Palate Using Cone Beam Computed Tomography |
title_fullStr |
Intra- and Interobserver Reliability of Bone Volume Estimation Using OsiriX Software in Patients with Cleft Lip and Palate Using Cone Beam Computed Tomography |
title_full_unstemmed |
Intra- and Interobserver Reliability of Bone Volume Estimation Using OsiriX Software in Patients with Cleft Lip and Palate Using Cone Beam Computed Tomography |
title_sort |
intra- and interobserver reliability of bone volume estimation using osirix software in patients with cleft lip and palate using cone beam computed tomography |
publisher |
MDPI AG |
series |
Dentistry Journal |
issn |
2304-6767 |
publishDate |
2021-01-01 |
description |
The objective of the current study was to evaluate intra- and interobserver bone volume measurements and effect of orientation on the reliability of bone volume evaluation in as-acquired vis-à-vis oriented cone beam computed tomography scans using Osirix software and possible correlation between gender, age, and bone volume required. For this, 31 cone beam computed tomography (CBCT) scans of 14 girls and 17 boys (aged 9–13) with unilateral cleft lip and/or palate who met the inclusion criteria were analyzed. Efficacy and reliability of third party software Osirix for bone volume calculation was assessed using as acquired and oriented volumes by three specialists (a radiologist, an orthodontist, and an oral maxillofacial surgeon). The dataset and readings were anonymized to prevent any bias. Two-way mixed model analysis on as-acquired and oriented observations exhibited intra-class coefficient (ICC) values ≥ 0.90. Wilcoxon signed rank test (<i>p</i> = 0.10) and Kruskal–Wallis ANOVA (<i>p</i> = 0.46) indicated that although a clinical difference in volume assessment was seen between as-acquired and oriented observations (inter-observer and intra-observer), it was statistically insignificant. Spearman’s bi-variate correlation analysis revealed a significant relation between the type (side) of cleft and bone volume required to fill the defect (<i>p</i> < 0.05). Although there was clinical difference in bone volume measurement by the three observers, it was insignificant statistically. Clefts on the left side in the patients had significantly more bone required than the right side, whereas age and gender had no relation with bone needed to fill the defect. OsiriX software provided good reliability in measurements of bone volume. |
topic |
cleft lip and palate unilateral cleft CBCT Osirix bone volume calculation SABG |
url |
https://www.mdpi.com/2304-6767/9/2/14 |
work_keys_str_mv |
AT anurajsinghkochhar intraandinterobserverreliabilityofbonevolumeestimationusingosirixsoftwareinpatientswithcleftlipandpalateusingconebeamcomputedtomography AT manindersinghsidhu intraandinterobserverreliabilityofbonevolumeestimationusingosirixsoftwareinpatientswithcleftlipandpalateusingconebeamcomputedtomography AT monaprabhakar intraandinterobserverreliabilityofbonevolumeestimationusingosirixsoftwareinpatientswithcleftlipandpalateusingconebeamcomputedtomography AT ritashabhasin intraandinterobserverreliabilityofbonevolumeestimationusingosirixsoftwareinpatientswithcleftlipandpalateusingconebeamcomputedtomography AT gulsheenkaurkochhar intraandinterobserverreliabilityofbonevolumeestimationusingosirixsoftwareinpatientswithcleftlipandpalateusingconebeamcomputedtomography AT himanshudadlani intraandinterobserverreliabilityofbonevolumeestimationusingosirixsoftwareinpatientswithcleftlipandpalateusingconebeamcomputedtomography AT gianricospagnuolo intraandinterobserverreliabilityofbonevolumeestimationusingosirixsoftwareinpatientswithcleftlipandpalateusingconebeamcomputedtomography AT viralvijaymehta intraandinterobserverreliabilityofbonevolumeestimationusingosirixsoftwareinpatientswithcleftlipandpalateusingconebeamcomputedtomography |
_version_ |
1724327427013869568 |