Evaluation of the Efficacy and Correlation between Blood Glucose Measured Using Glucometers and Enzymatic Laboratory Methods

<p><strong><em>Background and Objectives:</em></strong> Diabetes Mellitus (DM) is the most common chronic metabolic disease, with many complications including renal failure, blindness and non-traumatic amputation, so it is importa...

Full description

Bibliographic Details
Main Author: R Rasouli
Format: Article
Language:fas
Published: Qom University of Medical Sciences 2012-05-01
Series:Majallah-i Dānishgāh-i ̒Ulūm-i Pizishkī-i Qum
Online Access:http://journal.muq.ac.ir/en/index.php/jmuqen/article/view/196
id doaj-0fa5f657deed4bb0bc6fb2533a6df6a4
record_format Article
spelling doaj-0fa5f657deed4bb0bc6fb2533a6df6a42020-11-24T23:23:50ZfasQom University of Medical SciencesMajallah-i Dānishgāh-i ̒Ulūm-i Pizishkī-i Qum1735-77992008-13752012-05-0154Evaluation of the Efficacy and Correlation between Blood Glucose Measured Using Glucometers and Enzymatic Laboratory MethodsR Rasouli<p><strong><em>Background and Objectives:</em></strong> Diabetes Mellitus (DM) is the most common chronic metabolic disease, with many complications including renal failure, blindness and non-traumatic amputation, so it is important to monitor and regulate blood glucose. Considering how easy home blood glucose monitoring is, we decided to evaluate the performance of two available glucometers for detection of blood glucose compared with standard laboratory methods.</p><p><span style="text-decoration: underline;"> </span></p><p><strong><em>Methods:</em></strong> In this analytical study, we compared the capillary blood glucose levels of 60 volunteers with mean age of 32.8±9.6 years in Tabriz Mehr Laboratory as determined by test strips (two different Glucometers) with venous blood glucose levels’ measurements by the enzymatic method (the standard laboratory kit). Data were analyzed using one way-ANOVA test, T-test, Pearson correlation and Bland and Altman plot.</p><p><span style="text-decoration: underline;"> </span></p><p><strong><em>Results:</em></strong> The mean differences of No: 1 and No: 2 Glucometers with enzymatic laboratory method were 20.78±11.61 and 4.5±3.76mg/dl respectively. The one way ANOVA test indicated significant differences between three methods (p<0.05). Further Duncan's test revealed significant differences between two devices (p=0.001) and device No.1 and laboratory method (p=0.001); however, the differences between device No.2 and laboratory method were not statistically significant (p=0.83).</p><p><span style="text-decoration: underline;"> </span></p><p><strong><em>Conclusion:</em></strong> According to the results, calibrating the devices with laboratory instruments in order to make major clinical decisions is recommended.</p>http://journal.muq.ac.ir/en/index.php/jmuqen/article/view/196
collection DOAJ
language fas
format Article
sources DOAJ
author R Rasouli
spellingShingle R Rasouli
Evaluation of the Efficacy and Correlation between Blood Glucose Measured Using Glucometers and Enzymatic Laboratory Methods
Majallah-i Dānishgāh-i ̒Ulūm-i Pizishkī-i Qum
author_facet R Rasouli
author_sort R Rasouli
title Evaluation of the Efficacy and Correlation between Blood Glucose Measured Using Glucometers and Enzymatic Laboratory Methods
title_short Evaluation of the Efficacy and Correlation between Blood Glucose Measured Using Glucometers and Enzymatic Laboratory Methods
title_full Evaluation of the Efficacy and Correlation between Blood Glucose Measured Using Glucometers and Enzymatic Laboratory Methods
title_fullStr Evaluation of the Efficacy and Correlation between Blood Glucose Measured Using Glucometers and Enzymatic Laboratory Methods
title_full_unstemmed Evaluation of the Efficacy and Correlation between Blood Glucose Measured Using Glucometers and Enzymatic Laboratory Methods
title_sort evaluation of the efficacy and correlation between blood glucose measured using glucometers and enzymatic laboratory methods
publisher Qom University of Medical Sciences
series Majallah-i Dānishgāh-i ̒Ulūm-i Pizishkī-i Qum
issn 1735-7799
2008-1375
publishDate 2012-05-01
description <p><strong><em>Background and Objectives:</em></strong> Diabetes Mellitus (DM) is the most common chronic metabolic disease, with many complications including renal failure, blindness and non-traumatic amputation, so it is important to monitor and regulate blood glucose. Considering how easy home blood glucose monitoring is, we decided to evaluate the performance of two available glucometers for detection of blood glucose compared with standard laboratory methods.</p><p><span style="text-decoration: underline;"> </span></p><p><strong><em>Methods:</em></strong> In this analytical study, we compared the capillary blood glucose levels of 60 volunteers with mean age of 32.8±9.6 years in Tabriz Mehr Laboratory as determined by test strips (two different Glucometers) with venous blood glucose levels’ measurements by the enzymatic method (the standard laboratory kit). Data were analyzed using one way-ANOVA test, T-test, Pearson correlation and Bland and Altman plot.</p><p><span style="text-decoration: underline;"> </span></p><p><strong><em>Results:</em></strong> The mean differences of No: 1 and No: 2 Glucometers with enzymatic laboratory method were 20.78±11.61 and 4.5±3.76mg/dl respectively. The one way ANOVA test indicated significant differences between three methods (p<0.05). Further Duncan's test revealed significant differences between two devices (p=0.001) and device No.1 and laboratory method (p=0.001); however, the differences between device No.2 and laboratory method were not statistically significant (p=0.83).</p><p><span style="text-decoration: underline;"> </span></p><p><strong><em>Conclusion:</em></strong> According to the results, calibrating the devices with laboratory instruments in order to make major clinical decisions is recommended.</p>
url http://journal.muq.ac.ir/en/index.php/jmuqen/article/view/196
work_keys_str_mv AT rrasouli evaluationoftheefficacyandcorrelationbetweenbloodglucosemeasuredusingglucometersandenzymaticlaboratorymethods
_version_ 1725563429058510848