Overvoltages transferred from a network of 220 kV to 15.65 kV level of the step-up transformer in HPP 'Bajina Bašta'

The paper presents the results of research in lightning surge waves and switching overvoltages transferred from a network of 220 kV to the 15.65 kV level of the step-up transformer in HPP 'Bajina Bašta'. Analysis of survey results lead to conclusion that transferred overvoltages can endang...

Full description

Bibliographic Details
Main Authors: Vukelja Petar, Mrvić Jovan
Format: Article
Language:English
Published: Electrical Engineering Institute Nikola Tesla 2011-01-01
Series:Zbornik Radova: Elektrotehnički Institut "Nikola Tesla"
Subjects:
Online Access:http://scindeks-clanci.ceon.rs/data/pdf/0350-8528/2011/0350-85281121223V.pdf
id doaj-0f9cfdbd816145f687547393e1724a5e
record_format Article
spelling doaj-0f9cfdbd816145f687547393e1724a5e2020-11-24T22:33:37ZengElectrical Engineering Institute Nikola TeslaZbornik Radova: Elektrotehnički Institut "Nikola Tesla"0350-85282406-12122011-01-0120112122323910.5937/zreint1121223V0350-85281121223VOvervoltages transferred from a network of 220 kV to 15.65 kV level of the step-up transformer in HPP 'Bajina Bašta'Vukelja Petar0Mrvić Jovan1University of Belgrade, Electrical Engineering Institute “Nikola Tesla“, Belgrade, Belgrade, SerbiaUniversity of Belgrade, Electrical Engineering Institute “Nikola Tesla“, Belgrade, Belgrade, SerbiaThe paper presents the results of research in lightning surge waves and switching overvoltages transferred from a network of 220 kV to the 15.65 kV level of the step-up transformer in HPP 'Bajina Bašta'. Analysis of survey results lead to conclusion that transferred overvoltages can endanger 15.65 kV transformer windings and stator winding insulation. It was therefore suggested for the protection of the 15.65 kV isolation to install metal oxide surge arresters at a suitable place between the power generator bus bars and earthing.http://scindeks-clanci.ceon.rs/data/pdf/0350-8528/2011/0350-85281121223V.pdfovervoltagesinsulationtransformergenerator
collection DOAJ
language English
format Article
sources DOAJ
author Vukelja Petar
Mrvić Jovan
spellingShingle Vukelja Petar
Mrvić Jovan
Overvoltages transferred from a network of 220 kV to 15.65 kV level of the step-up transformer in HPP 'Bajina Bašta'
Zbornik Radova: Elektrotehnički Institut "Nikola Tesla"
overvoltages
insulation
transformer
generator
author_facet Vukelja Petar
Mrvić Jovan
author_sort Vukelja Petar
title Overvoltages transferred from a network of 220 kV to 15.65 kV level of the step-up transformer in HPP 'Bajina Bašta'
title_short Overvoltages transferred from a network of 220 kV to 15.65 kV level of the step-up transformer in HPP 'Bajina Bašta'
title_full Overvoltages transferred from a network of 220 kV to 15.65 kV level of the step-up transformer in HPP 'Bajina Bašta'
title_fullStr Overvoltages transferred from a network of 220 kV to 15.65 kV level of the step-up transformer in HPP 'Bajina Bašta'
title_full_unstemmed Overvoltages transferred from a network of 220 kV to 15.65 kV level of the step-up transformer in HPP 'Bajina Bašta'
title_sort overvoltages transferred from a network of 220 kv to 15.65 kv level of the step-up transformer in hpp 'bajina bašta'
publisher Electrical Engineering Institute Nikola Tesla
series Zbornik Radova: Elektrotehnički Institut "Nikola Tesla"
issn 0350-8528
2406-1212
publishDate 2011-01-01
description The paper presents the results of research in lightning surge waves and switching overvoltages transferred from a network of 220 kV to the 15.65 kV level of the step-up transformer in HPP 'Bajina Bašta'. Analysis of survey results lead to conclusion that transferred overvoltages can endanger 15.65 kV transformer windings and stator winding insulation. It was therefore suggested for the protection of the 15.65 kV isolation to install metal oxide surge arresters at a suitable place between the power generator bus bars and earthing.
topic overvoltages
insulation
transformer
generator
url http://scindeks-clanci.ceon.rs/data/pdf/0350-8528/2011/0350-85281121223V.pdf
work_keys_str_mv AT vukeljapetar overvoltagestransferredfromanetworkof220kvto1565kvlevelofthestepuptransformerinhppbajinabasta
AT mrvicjovan overvoltagestransferredfromanetworkof220kvto1565kvlevelofthestepuptransformerinhppbajinabasta
_version_ 1725730340245340160