Influence of Insertion Torque on Clinical and Biological Outcomes before and after Loading of Mandibular Implant-Retained Overdentures in Atrophic Edentulous Mandibles

Aim. To evaluate the influence of primary insertion torque (IT) values of narrow dental implants on the peri-implant health, implant stability, immunoinflammatory responses, bone loss, and success and survival rates. Methods. Thirty-one edentulous patients received two narrow implants (2.9x10mm, Fac...

Full description

Bibliographic Details
Main Authors: Fernanda Faot, Amália Machado Bielemann, Alessandra Julie Schuster, Raissa Micaella Marcello-Machado, Altair Antoninha Del Bel Cury, Gustavo G. Nascimento, Otacílio Luiz Chagas-Junior
Format: Article
Language:English
Published: Hindawi Limited 2019-01-01
Series:BioMed Research International
Online Access:http://dx.doi.org/10.1155/2019/8132520
id doaj-0f23bd9992bc4f018ad47e63cc935890
record_format Article
spelling doaj-0f23bd9992bc4f018ad47e63cc9358902020-11-24T20:56:10ZengHindawi LimitedBioMed Research International2314-61332314-61412019-01-01201910.1155/2019/81325208132520Influence of Insertion Torque on Clinical and Biological Outcomes before and after Loading of Mandibular Implant-Retained Overdentures in Atrophic Edentulous MandiblesFernanda Faot0Amália Machado Bielemann1Alessandra Julie Schuster2Raissa Micaella Marcello-Machado3Altair Antoninha Del Bel Cury4Gustavo G. Nascimento5Otacílio Luiz Chagas-Junior6Department of Restorative Dentistry, School of Dentistry, Federal University of Pelotas, RS, BrazilGraduate Program in Dentistry, School of Dentistry, Federal University of Pelotas, RS, BrazilGraduate Program in Dentistry, School of Dentistry, Federal University of Pelotas, RS, BrazilDepartment of Prosthodontics and Periodontology, Piracicaba Dental School, State University of Campinas, Piracicaba, SP, BrazilDepartment of Prosthodontics and Periodontology, Piracicaba Dental School, State University of Campinas, Piracicaba, SP, BrazilSection of Periodontology, Department of Dentistry and Oral Health, Aarhus University, Aarhus, DenmarkDepartment of Oral and Maxillofacial Surgery and Maxillofacial Prosthodontics, School of Dentistry, Federal University of Pelotas, RS, BrazilAim. To evaluate the influence of primary insertion torque (IT) values of narrow dental implants on the peri-implant health, implant stability, immunoinflammatory responses, bone loss, and success and survival rates. Methods. Thirty-one edentulous patients received two narrow implants (2.9x10mm, Facility NeoPoros) to retain mandibular overdentures. The implants were categorized in four groups according to their IT: (G1) IT > 10 Ncm; (G2) IT ≥ 10Ncm and ≤ 30 Ncm; (G3) IT >30Ncm and < 45Ncm; (G4) IT ≥ 45Ncm, and all implants were loaded after 3 months of healing. The following clinical outcomes were evaluated 1, 3, 6, and 12 months after implant insertion: (i) peri-implant tissue health (PH), gingival index (GI), plaque index (PI), calculus presence (CP), probing depth (PD), and bleeding on probing (BOP); (ii) implant stability quotient (ISQ) by resonance frequency analysis; and (iii) IL-1β and TNF-α concentration in the peri-implant crevicular fluid. The marginal bone level (MBL) and changes (MBC) were evaluated. The Chi2 test, Kruskal-Wallis test, mixed-effects regression analysis, and the Kendall rank correlation coefficient were used for statistical analysis (α = 5%). Results. G1 presented the highest PD at all evaluated periods. G2 presented higher PI at month 6 and 12. G4 showed increased GI at month 3 and 12 and more CP at month 1 (p=.003). G2 and G4 had higher ISQ values over the study period, while those from G1 and G3 presented lower ISQ values. The IL-1β concentration increased until month 12 and was independent of IT and bone type; G4 had a higher IL-1β concentration in month 3 than the other groups (p=.015). The TNF-α release was negatively correlated with IT, and TNF-α release was highest in G1 at month 12. The MBL immediately after surgery and the MBC at month 12 were similar between the groups, and G4 presented a positive MBC at month 12. The survival and success rates were 75% for G1, 81.3% for G2, 64.3% for G3, and 95% for G4. Conclusion. The IT did not influence the clinical outcomes and the peri-implant immunoinflammatory responses and was weakly correlated with the narrow dental implants primary stability. The observed success rates suggest that the ideal IT for atrophic fully edentulous patients may deviate from the standardized IT of 32 Ncm.http://dx.doi.org/10.1155/2019/8132520
collection DOAJ
language English
format Article
sources DOAJ
author Fernanda Faot
Amália Machado Bielemann
Alessandra Julie Schuster
Raissa Micaella Marcello-Machado
Altair Antoninha Del Bel Cury
Gustavo G. Nascimento
Otacílio Luiz Chagas-Junior
spellingShingle Fernanda Faot
Amália Machado Bielemann
Alessandra Julie Schuster
Raissa Micaella Marcello-Machado
Altair Antoninha Del Bel Cury
Gustavo G. Nascimento
Otacílio Luiz Chagas-Junior
Influence of Insertion Torque on Clinical and Biological Outcomes before and after Loading of Mandibular Implant-Retained Overdentures in Atrophic Edentulous Mandibles
BioMed Research International
author_facet Fernanda Faot
Amália Machado Bielemann
Alessandra Julie Schuster
Raissa Micaella Marcello-Machado
Altair Antoninha Del Bel Cury
Gustavo G. Nascimento
Otacílio Luiz Chagas-Junior
author_sort Fernanda Faot
title Influence of Insertion Torque on Clinical and Biological Outcomes before and after Loading of Mandibular Implant-Retained Overdentures in Atrophic Edentulous Mandibles
title_short Influence of Insertion Torque on Clinical and Biological Outcomes before and after Loading of Mandibular Implant-Retained Overdentures in Atrophic Edentulous Mandibles
title_full Influence of Insertion Torque on Clinical and Biological Outcomes before and after Loading of Mandibular Implant-Retained Overdentures in Atrophic Edentulous Mandibles
title_fullStr Influence of Insertion Torque on Clinical and Biological Outcomes before and after Loading of Mandibular Implant-Retained Overdentures in Atrophic Edentulous Mandibles
title_full_unstemmed Influence of Insertion Torque on Clinical and Biological Outcomes before and after Loading of Mandibular Implant-Retained Overdentures in Atrophic Edentulous Mandibles
title_sort influence of insertion torque on clinical and biological outcomes before and after loading of mandibular implant-retained overdentures in atrophic edentulous mandibles
publisher Hindawi Limited
series BioMed Research International
issn 2314-6133
2314-6141
publishDate 2019-01-01
description Aim. To evaluate the influence of primary insertion torque (IT) values of narrow dental implants on the peri-implant health, implant stability, immunoinflammatory responses, bone loss, and success and survival rates. Methods. Thirty-one edentulous patients received two narrow implants (2.9x10mm, Facility NeoPoros) to retain mandibular overdentures. The implants were categorized in four groups according to their IT: (G1) IT > 10 Ncm; (G2) IT ≥ 10Ncm and ≤ 30 Ncm; (G3) IT >30Ncm and < 45Ncm; (G4) IT ≥ 45Ncm, and all implants were loaded after 3 months of healing. The following clinical outcomes were evaluated 1, 3, 6, and 12 months after implant insertion: (i) peri-implant tissue health (PH), gingival index (GI), plaque index (PI), calculus presence (CP), probing depth (PD), and bleeding on probing (BOP); (ii) implant stability quotient (ISQ) by resonance frequency analysis; and (iii) IL-1β and TNF-α concentration in the peri-implant crevicular fluid. The marginal bone level (MBL) and changes (MBC) were evaluated. The Chi2 test, Kruskal-Wallis test, mixed-effects regression analysis, and the Kendall rank correlation coefficient were used for statistical analysis (α = 5%). Results. G1 presented the highest PD at all evaluated periods. G2 presented higher PI at month 6 and 12. G4 showed increased GI at month 3 and 12 and more CP at month 1 (p=.003). G2 and G4 had higher ISQ values over the study period, while those from G1 and G3 presented lower ISQ values. The IL-1β concentration increased until month 12 and was independent of IT and bone type; G4 had a higher IL-1β concentration in month 3 than the other groups (p=.015). The TNF-α release was negatively correlated with IT, and TNF-α release was highest in G1 at month 12. The MBL immediately after surgery and the MBC at month 12 were similar between the groups, and G4 presented a positive MBC at month 12. The survival and success rates were 75% for G1, 81.3% for G2, 64.3% for G3, and 95% for G4. Conclusion. The IT did not influence the clinical outcomes and the peri-implant immunoinflammatory responses and was weakly correlated with the narrow dental implants primary stability. The observed success rates suggest that the ideal IT for atrophic fully edentulous patients may deviate from the standardized IT of 32 Ncm.
url http://dx.doi.org/10.1155/2019/8132520
work_keys_str_mv AT fernandafaot influenceofinsertiontorqueonclinicalandbiologicaloutcomesbeforeandafterloadingofmandibularimplantretainedoverdenturesinatrophicedentulousmandibles
AT amaliamachadobielemann influenceofinsertiontorqueonclinicalandbiologicaloutcomesbeforeandafterloadingofmandibularimplantretainedoverdenturesinatrophicedentulousmandibles
AT alessandrajulieschuster influenceofinsertiontorqueonclinicalandbiologicaloutcomesbeforeandafterloadingofmandibularimplantretainedoverdenturesinatrophicedentulousmandibles
AT raissamicaellamarcellomachado influenceofinsertiontorqueonclinicalandbiologicaloutcomesbeforeandafterloadingofmandibularimplantretainedoverdenturesinatrophicedentulousmandibles
AT altairantoninhadelbelcury influenceofinsertiontorqueonclinicalandbiologicaloutcomesbeforeandafterloadingofmandibularimplantretainedoverdenturesinatrophicedentulousmandibles
AT gustavognascimento influenceofinsertiontorqueonclinicalandbiologicaloutcomesbeforeandafterloadingofmandibularimplantretainedoverdenturesinatrophicedentulousmandibles
AT otacilioluizchagasjunior influenceofinsertiontorqueonclinicalandbiologicaloutcomesbeforeandafterloadingofmandibularimplantretainedoverdenturesinatrophicedentulousmandibles
_version_ 1716790519505354752