Influence of Brick Walls on the Temperature Distribution in Steel Columns in Fire
This paper reports on a study of steel columns embedded in walls in fire. Several fire resistance tests were carried out at the Laboratory of Testing Materials and Structures of the University of Coimbra, in Portugal. The temperatures registered in several points of the experimental models are compa...
Main Authors: | António J. P. Moura Correia, Joao Paulo C. Rodrigues, Valdir Pignatta e Silvac |
---|---|
Format: | Article |
Language: | English |
Published: |
CTU Central Library
2009-01-01
|
Series: | Acta Polytechnica |
Subjects: | |
Online Access: | https://ojs.cvut.cz/ojs/index.php/ap/article/view/1077 |
Similar Items
-
Tubular composite columns in a non-symmetrical fire
by: Markku Heinisuo, et al.
Published: (2014-08-01) -
Concrete Filled Steel Tube Columns - Test compared with Eurocode4
by: Lam, Dennis, et al.
Published: (2013) -
Designing Eccentrically Loaded Concrete Encased Steel Composite Columns to Eurocode 4 using Second-Order Analysis
by: Lam, Dennis
Published: (2013) -
Axial Compression Performance of Post-Fire Concrete Columns Strengthened Using Thin-Walled Steel Tubes
by: Yi Luo, et al.
Published: (2019-09-01) -
A Database for Composite Columns
by: Kim, Dong Keon
Published: (2005)