Detection of vision and /or hearing loss using the interRAI Community Health Assessment aligns well with common behavioral vision/hearing measurements.
This study's main objective was to assess the sensitivity and specificity of the interRAI Community Health Assessment (CHA) for detecting the presence of vision loss (VL), hearing loss (HL) or both (Dual Sensory Loss, DSL) when compared against performance-based measures of vision and hearing....
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Public Library of Science (PLoS)
2019-01-01
|
Series: | PLoS ONE |
Online Access: | https://doi.org/10.1371/journal.pone.0223123 |
id |
doaj-0e904d5f64d04e2d953c8c6b1e4b77e2 |
---|---|
record_format |
Article |
spelling |
doaj-0e904d5f64d04e2d953c8c6b1e4b77e22021-03-03T21:06:44ZengPublic Library of Science (PLoS)PLoS ONE1932-62032019-01-011410e022312310.1371/journal.pone.0223123Detection of vision and /or hearing loss using the interRAI Community Health Assessment aligns well with common behavioral vision/hearing measurements.Andrea Urqueta AlfaroDawn M GuthrieNatalie A PhillipsM Kathleen Pichora-FullerPaul MickCathy McGrawWalter WittichThis study's main objective was to assess the sensitivity and specificity of the interRAI Community Health Assessment (CHA) for detecting the presence of vision loss (VL), hearing loss (HL) or both (Dual Sensory Loss, DSL) when compared against performance-based measures of vision and hearing. The interRAI CHA and the Montreal Cognitive Assessment (MoCA) were administered to 200 adults (61+ years of age) who had VL, HL or DSL. We calculated the sensitivity and specificity of the interRAI CHA for detecting sensory impairments using as the gold standard performance based measurements of hearing (pure-tone audiogram) and vision (distance acuity) as determined from the rehabilitation centre record. Results were divided according to participants' cognitive status, as measured by the MoCA and the Cognitive Performance Scale (CPS, embedded within the interRAI CHA). Overall, sensitivity was 100% for VL, 97.1% for HL, and 96.9% for DSL. Specificity was at least 93% in all three groups. In participants who failed the MoCA (i.e., at risk of mild cognitive impairment), the sensitivity was 100% for VL, 96.8% for HL and 96.2% for DSL; in those who were not at risk, the sensitivity was 100% for VL, and 97.4% for HL and DSL. In participants classified by the CPS as borderline intact or mild cognitively impaired, sensitivity was 100% in all groups; in those classified as cognitively intact, sensitivity was 100% for VL, 97.0% for HL, and 96.8% for DSL. These results suggest that the interRAI CHA detects VL, HL, and DSL in high agreement with performance-based measurements of vision and hearing. The interRAI CHA shows high accuracy even in participants with mild cognitive difficulties. Since results were found in a specific population of older rehabilitation clients who all had sensory difficulties, further research is needed to understand its role in screening in other more diverse groups.https://doi.org/10.1371/journal.pone.0223123 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Andrea Urqueta Alfaro Dawn M Guthrie Natalie A Phillips M Kathleen Pichora-Fuller Paul Mick Cathy McGraw Walter Wittich |
spellingShingle |
Andrea Urqueta Alfaro Dawn M Guthrie Natalie A Phillips M Kathleen Pichora-Fuller Paul Mick Cathy McGraw Walter Wittich Detection of vision and /or hearing loss using the interRAI Community Health Assessment aligns well with common behavioral vision/hearing measurements. PLoS ONE |
author_facet |
Andrea Urqueta Alfaro Dawn M Guthrie Natalie A Phillips M Kathleen Pichora-Fuller Paul Mick Cathy McGraw Walter Wittich |
author_sort |
Andrea Urqueta Alfaro |
title |
Detection of vision and /or hearing loss using the interRAI Community Health Assessment aligns well with common behavioral vision/hearing measurements. |
title_short |
Detection of vision and /or hearing loss using the interRAI Community Health Assessment aligns well with common behavioral vision/hearing measurements. |
title_full |
Detection of vision and /or hearing loss using the interRAI Community Health Assessment aligns well with common behavioral vision/hearing measurements. |
title_fullStr |
Detection of vision and /or hearing loss using the interRAI Community Health Assessment aligns well with common behavioral vision/hearing measurements. |
title_full_unstemmed |
Detection of vision and /or hearing loss using the interRAI Community Health Assessment aligns well with common behavioral vision/hearing measurements. |
title_sort |
detection of vision and /or hearing loss using the interrai community health assessment aligns well with common behavioral vision/hearing measurements. |
publisher |
Public Library of Science (PLoS) |
series |
PLoS ONE |
issn |
1932-6203 |
publishDate |
2019-01-01 |
description |
This study's main objective was to assess the sensitivity and specificity of the interRAI Community Health Assessment (CHA) for detecting the presence of vision loss (VL), hearing loss (HL) or both (Dual Sensory Loss, DSL) when compared against performance-based measures of vision and hearing. The interRAI CHA and the Montreal Cognitive Assessment (MoCA) were administered to 200 adults (61+ years of age) who had VL, HL or DSL. We calculated the sensitivity and specificity of the interRAI CHA for detecting sensory impairments using as the gold standard performance based measurements of hearing (pure-tone audiogram) and vision (distance acuity) as determined from the rehabilitation centre record. Results were divided according to participants' cognitive status, as measured by the MoCA and the Cognitive Performance Scale (CPS, embedded within the interRAI CHA). Overall, sensitivity was 100% for VL, 97.1% for HL, and 96.9% for DSL. Specificity was at least 93% in all three groups. In participants who failed the MoCA (i.e., at risk of mild cognitive impairment), the sensitivity was 100% for VL, 96.8% for HL and 96.2% for DSL; in those who were not at risk, the sensitivity was 100% for VL, and 97.4% for HL and DSL. In participants classified by the CPS as borderline intact or mild cognitively impaired, sensitivity was 100% in all groups; in those classified as cognitively intact, sensitivity was 100% for VL, 97.0% for HL, and 96.8% for DSL. These results suggest that the interRAI CHA detects VL, HL, and DSL in high agreement with performance-based measurements of vision and hearing. The interRAI CHA shows high accuracy even in participants with mild cognitive difficulties. Since results were found in a specific population of older rehabilitation clients who all had sensory difficulties, further research is needed to understand its role in screening in other more diverse groups. |
url |
https://doi.org/10.1371/journal.pone.0223123 |
work_keys_str_mv |
AT andreaurquetaalfaro detectionofvisionandorhearinglossusingtheinterraicommunityhealthassessmentalignswellwithcommonbehavioralvisionhearingmeasurements AT dawnmguthrie detectionofvisionandorhearinglossusingtheinterraicommunityhealthassessmentalignswellwithcommonbehavioralvisionhearingmeasurements AT natalieaphillips detectionofvisionandorhearinglossusingtheinterraicommunityhealthassessmentalignswellwithcommonbehavioralvisionhearingmeasurements AT mkathleenpichorafuller detectionofvisionandorhearinglossusingtheinterraicommunityhealthassessmentalignswellwithcommonbehavioralvisionhearingmeasurements AT paulmick detectionofvisionandorhearinglossusingtheinterraicommunityhealthassessmentalignswellwithcommonbehavioralvisionhearingmeasurements AT cathymcgraw detectionofvisionandorhearinglossusingtheinterraicommunityhealthassessmentalignswellwithcommonbehavioralvisionhearingmeasurements AT walterwittich detectionofvisionandorhearinglossusingtheinterraicommunityhealthassessmentalignswellwithcommonbehavioralvisionhearingmeasurements |
_version_ |
1714818626009169920 |