Summary: | The soil-structure interaction (SSI) can significantly alter the characteristics of recorded motions in buildings. The ratio of Fourier amplitude spectrum of the top-story accelerations to that of the foundation accelerations permits the identification of the natural frequency of the fixed-base building. In this study, records of the Chi-Chi earthquake and the 1226 Hengchun earthquake doublet from the structural array in a 51-story highrise building are used to obtain the dynamic characteristics of the buildings by the transfer function (TF) method. As a result, the acceleration amplification of seismic excitation on the 47th storey of buildings is 4.24, in the horizontal component, from the Chi-Chi earthquake data greater than those of the 1226 Hengchun earthquake doublet with a value of 2.82 and 2.06, respectively. In addition, from the spectral ratio of the accelerations (47th floor/basement), together with the Fourier Amplitude Spectrum (FAS) of the 47th floor and basement accelerations, it is noted that the peaks of the 47th floor FAS and the spectral ratio appear to coincide with each other from the records of 1226 Hengchun earthquake doublet, suggesting that there is no significant SSI effects in both the longitudinal and transverse directions.
|