Comparative evaluation of buckling resistance of Proglider and One-G file: An in vitro study

Aim: Comparative evaluation of buckling resistance of Proglider and One-G file, An In vitro Study. Materials and Methods: The test instruments – Proglider and One-G files were subjected to a devised buckling resistance test, which consisted of the application of an increasing load in the axial direc...

Full description

Bibliographic Details
Main Authors: Priyanka Himmatrao Patil, Meenal Nitin Gulve, Swapnil Janardan Kolhe
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2018-01-01
Series:Endodontology
Subjects:
Online Access:http://www.endodontologyonweb.org/article.asp?issn=0970-7212;year=2018;volume=30;issue=1;spage=21;epage=24;aulast=Patil
id doaj-0dc7a6ce42b545b5bb3b503b2d880d03
record_format Article
spelling doaj-0dc7a6ce42b545b5bb3b503b2d880d032020-11-24T21:27:14ZengWolters Kluwer Medknow PublicationsEndodontology0970-72122018-01-01301212410.4103/endo.endo_121_17Comparative evaluation of buckling resistance of Proglider and One-G file: An in vitro studyPriyanka Himmatrao PatilMeenal Nitin GulveSwapnil Janardan KolheAim: Comparative evaluation of buckling resistance of Proglider and One-G file, An In vitro Study. Materials and Methods: The test instruments – Proglider and One-G files were subjected to a devised buckling resistance test, which consisted of the application of an increasing load in the axial direction of the instrument by using a universal testing machine. The maximum load required to generate a lateral elastic displacement of 1 mm was recorded for each instrument. Data were analyzed using the one-way ANOVA test. Results: The results indicated that the buckling resistance of One-G files is significantly better than Proglider files (P < 0.05). Conclusion: One-G rotary files manufactured with conventional nickel-titanium alloy showed higher buckling resistance compared to Proglider files manufactured with M-wire alloy.http://www.endodontologyonweb.org/article.asp?issn=0970-7212;year=2018;volume=30;issue=1;spage=21;epage=24;aulast=PatilBuckling resistanceOne-GProglider
collection DOAJ
language English
format Article
sources DOAJ
author Priyanka Himmatrao Patil
Meenal Nitin Gulve
Swapnil Janardan Kolhe
spellingShingle Priyanka Himmatrao Patil
Meenal Nitin Gulve
Swapnil Janardan Kolhe
Comparative evaluation of buckling resistance of Proglider and One-G file: An in vitro study
Endodontology
Buckling resistance
One-G
Proglider
author_facet Priyanka Himmatrao Patil
Meenal Nitin Gulve
Swapnil Janardan Kolhe
author_sort Priyanka Himmatrao Patil
title Comparative evaluation of buckling resistance of Proglider and One-G file: An in vitro study
title_short Comparative evaluation of buckling resistance of Proglider and One-G file: An in vitro study
title_full Comparative evaluation of buckling resistance of Proglider and One-G file: An in vitro study
title_fullStr Comparative evaluation of buckling resistance of Proglider and One-G file: An in vitro study
title_full_unstemmed Comparative evaluation of buckling resistance of Proglider and One-G file: An in vitro study
title_sort comparative evaluation of buckling resistance of proglider and one-g file: an in vitro study
publisher Wolters Kluwer Medknow Publications
series Endodontology
issn 0970-7212
publishDate 2018-01-01
description Aim: Comparative evaluation of buckling resistance of Proglider and One-G file, An In vitro Study. Materials and Methods: The test instruments – Proglider and One-G files were subjected to a devised buckling resistance test, which consisted of the application of an increasing load in the axial direction of the instrument by using a universal testing machine. The maximum load required to generate a lateral elastic displacement of 1 mm was recorded for each instrument. Data were analyzed using the one-way ANOVA test. Results: The results indicated that the buckling resistance of One-G files is significantly better than Proglider files (P < 0.05). Conclusion: One-G rotary files manufactured with conventional nickel-titanium alloy showed higher buckling resistance compared to Proglider files manufactured with M-wire alloy.
topic Buckling resistance
One-G
Proglider
url http://www.endodontologyonweb.org/article.asp?issn=0970-7212;year=2018;volume=30;issue=1;spage=21;epage=24;aulast=Patil
work_keys_str_mv AT priyankahimmatraopatil comparativeevaluationofbucklingresistanceofprogliderandonegfileaninvitrostudy
AT meenalnitingulve comparativeevaluationofbucklingresistanceofprogliderandonegfileaninvitrostudy
AT swapniljanardankolhe comparativeevaluationofbucklingresistanceofprogliderandonegfileaninvitrostudy
_version_ 1725975848562982912