Study on the Effect of 4D-CT Special Reconstruction Images for Evaluation of the Cardiac Structure Dose in Radiotherapy for Breast Cancer

Objective: To study the dosimetric effect on special reconstruction images obtained from an electrocardiograph-gated four-dimensional computed tomography (ECG 4D-CT) series and compare it with the accumulation dose assessment of ECG 4D-CT.Methods: Fifteen patients underwent ECG 4D-CT scans to obtain...

Full description

Bibliographic Details
Main Authors: Ming Su, Guanzhong Gong, Xiaoping Qiu, Ying Tong, Qian Li, Yong Yin
Format: Article
Language:English
Published: Frontiers Media S.A. 2020-03-01
Series:Frontiers in Oncology
Subjects:
Online Access:https://www.frontiersin.org/article/10.3389/fonc.2020.00433/full
id doaj-0d5aaa6a5a7242a98fbff3266fb4b2ab
record_format Article
spelling doaj-0d5aaa6a5a7242a98fbff3266fb4b2ab2020-11-25T02:37:40ZengFrontiers Media S.A.Frontiers in Oncology2234-943X2020-03-011010.3389/fonc.2020.00433500089Study on the Effect of 4D-CT Special Reconstruction Images for Evaluation of the Cardiac Structure Dose in Radiotherapy for Breast CancerMing Su0Guanzhong Gong1Xiaoping Qiu2Ying Tong3Qian Li4Yong Yin5School of Nuclear Science and Technology, University of South China, Hengyang, ChinaShandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, ChinaSchool of Nuclear Science and Technology, University of South China, Hengyang, ChinaShandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, ChinaShandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, ChinaShandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, ChinaObjective: To study the dosimetric effect on special reconstruction images obtained from an electrocardiograph-gated four-dimensional computed tomography (ECG 4D-CT) series and compare it with the accumulation dose assessment of ECG 4D-CT.Methods: Fifteen patients underwent ECG 4D-CT scans to obtain a 4D-CT series. The 20 phase images of 0–95% were reconstructed at intervals of 5% of the cardiac cycle by the 4D-CT series. The 4D-CT series was specially reconstructed, and the maximum intensity projection (MIP), minimum intensity projection (MinIP), average intensity projection (AIP), and sum intensity projection (SIP) were obtained. The left ventricular muscle (LV) and the anterior descending branch of the left coronary artery (LAD) were delineated on all series. The intensity-modulated radiation therapy (IMRT) plan for left breast cancer was designed on the basis of the 0% phase, and the accumulative dose (Dose−acc) of 20 phases was obtained by deformation registration. The dose-volume indexes of the LV and LAD were compared based on different CT series.Results: The dose-volume indices of V5, V30, V40, Dmax, and Dmean of the LV on MIP images were 3.8, 2.0, 0.9, 3.8, and 1.7%, respectively (relative to the Dose−acc). There was no significant difference in V5 or Dmax between the MIP and Dose−acc (P > 0.05). The change rates of Dmax on the MinIP, SIP, and AIP images were 2.5, 3.1, and 1.5%, respectively (relative to the Dose−acc) (P < 0.05).Conclusion: In the dose-volume evaluation of the LV, V30, V40, and Dmean obtained by MIP were essentially the same as those obtained by the Dose−acc and can be used instead of the 4D-CT series to evaluate dose-volume indexes.https://www.frontiersin.org/article/10.3389/fonc.2020.00433/full4D-CTdose accumulationspecial reconstructionbreast cancerradiotherapycardiac structure
collection DOAJ
language English
format Article
sources DOAJ
author Ming Su
Guanzhong Gong
Xiaoping Qiu
Ying Tong
Qian Li
Yong Yin
spellingShingle Ming Su
Guanzhong Gong
Xiaoping Qiu
Ying Tong
Qian Li
Yong Yin
Study on the Effect of 4D-CT Special Reconstruction Images for Evaluation of the Cardiac Structure Dose in Radiotherapy for Breast Cancer
Frontiers in Oncology
4D-CT
dose accumulation
special reconstruction
breast cancer
radiotherapy
cardiac structure
author_facet Ming Su
Guanzhong Gong
Xiaoping Qiu
Ying Tong
Qian Li
Yong Yin
author_sort Ming Su
title Study on the Effect of 4D-CT Special Reconstruction Images for Evaluation of the Cardiac Structure Dose in Radiotherapy for Breast Cancer
title_short Study on the Effect of 4D-CT Special Reconstruction Images for Evaluation of the Cardiac Structure Dose in Radiotherapy for Breast Cancer
title_full Study on the Effect of 4D-CT Special Reconstruction Images for Evaluation of the Cardiac Structure Dose in Radiotherapy for Breast Cancer
title_fullStr Study on the Effect of 4D-CT Special Reconstruction Images for Evaluation of the Cardiac Structure Dose in Radiotherapy for Breast Cancer
title_full_unstemmed Study on the Effect of 4D-CT Special Reconstruction Images for Evaluation of the Cardiac Structure Dose in Radiotherapy for Breast Cancer
title_sort study on the effect of 4d-ct special reconstruction images for evaluation of the cardiac structure dose in radiotherapy for breast cancer
publisher Frontiers Media S.A.
series Frontiers in Oncology
issn 2234-943X
publishDate 2020-03-01
description Objective: To study the dosimetric effect on special reconstruction images obtained from an electrocardiograph-gated four-dimensional computed tomography (ECG 4D-CT) series and compare it with the accumulation dose assessment of ECG 4D-CT.Methods: Fifteen patients underwent ECG 4D-CT scans to obtain a 4D-CT series. The 20 phase images of 0–95% were reconstructed at intervals of 5% of the cardiac cycle by the 4D-CT series. The 4D-CT series was specially reconstructed, and the maximum intensity projection (MIP), minimum intensity projection (MinIP), average intensity projection (AIP), and sum intensity projection (SIP) were obtained. The left ventricular muscle (LV) and the anterior descending branch of the left coronary artery (LAD) were delineated on all series. The intensity-modulated radiation therapy (IMRT) plan for left breast cancer was designed on the basis of the 0% phase, and the accumulative dose (Dose−acc) of 20 phases was obtained by deformation registration. The dose-volume indexes of the LV and LAD were compared based on different CT series.Results: The dose-volume indices of V5, V30, V40, Dmax, and Dmean of the LV on MIP images were 3.8, 2.0, 0.9, 3.8, and 1.7%, respectively (relative to the Dose−acc). There was no significant difference in V5 or Dmax between the MIP and Dose−acc (P > 0.05). The change rates of Dmax on the MinIP, SIP, and AIP images were 2.5, 3.1, and 1.5%, respectively (relative to the Dose−acc) (P < 0.05).Conclusion: In the dose-volume evaluation of the LV, V30, V40, and Dmean obtained by MIP were essentially the same as those obtained by the Dose−acc and can be used instead of the 4D-CT series to evaluate dose-volume indexes.
topic 4D-CT
dose accumulation
special reconstruction
breast cancer
radiotherapy
cardiac structure
url https://www.frontiersin.org/article/10.3389/fonc.2020.00433/full
work_keys_str_mv AT mingsu studyontheeffectof4dctspecialreconstructionimagesforevaluationofthecardiacstructuredoseinradiotherapyforbreastcancer
AT guanzhonggong studyontheeffectof4dctspecialreconstructionimagesforevaluationofthecardiacstructuredoseinradiotherapyforbreastcancer
AT xiaopingqiu studyontheeffectof4dctspecialreconstructionimagesforevaluationofthecardiacstructuredoseinradiotherapyforbreastcancer
AT yingtong studyontheeffectof4dctspecialreconstructionimagesforevaluationofthecardiacstructuredoseinradiotherapyforbreastcancer
AT qianli studyontheeffectof4dctspecialreconstructionimagesforevaluationofthecardiacstructuredoseinradiotherapyforbreastcancer
AT yongyin studyontheeffectof4dctspecialreconstructionimagesforevaluationofthecardiacstructuredoseinradiotherapyforbreastcancer
_version_ 1724793952635191296