Investigation of the Specific Retention Volume of the Probe Volume and the Effects on the Polymer-Probe System by Inverse Gas Chromatography

In this study, the effects of probe quantities on retention volume and the physical and thermodynamic results of polymer-probe systems were investigated. For this purpose, by using inverse gas chromatographic method. Alcohols and alkanes with different chemical and physical properties were injected...

Full description

Bibliographic Details
Main Author: Mustafa Hamdi Karagöz
Format: Article
Language:English
Published: Hindawi Limited 2019-01-01
Series:International Journal of Polymer Science
Online Access:http://dx.doi.org/10.1155/2019/5623873
id doaj-0d540bf015ab43d29202ceec777569ed
record_format Article
spelling doaj-0d540bf015ab43d29202ceec777569ed2020-11-25T01:34:18ZengHindawi LimitedInternational Journal of Polymer Science1687-94221687-94302019-01-01201910.1155/2019/56238735623873Investigation of the Specific Retention Volume of the Probe Volume and the Effects on the Polymer-Probe System by Inverse Gas ChromatographyMustafa Hamdi Karagöz0Department of Chemistry, Van Yüzüncü Yıl University, 65080 Van, TurkeyIn this study, the effects of probe quantities on retention volume and the physical and thermodynamic results of polymer-probe systems were investigated. For this purpose, by using inverse gas chromatographic method. Alcohols and alkanes with different chemical and physical properties were injected as probes on homopolymer (2-cyclohexylidene-1,3-dioxolane-4-yl-methyl methacrylate) (CHMMA). Probe quantities of 0.3, 0.6, and 0.9 μl were selected, and an injection was made at every 10°C between 40 and 150°C. In addition, 3 μl volume probes were tried but reproducible results were not obtained in these volumes and the detector was observed to be out of order after several injections. It has been observed that the specific retention volume of alcohols and alkanes partially increased by increasing the injection amount. A linear relationship was observed between probe quantities and specific retention volume. This linear relationship is apparent from the specific retention volume values, where the probes are independent of the physical and chemical structures. It was observed that the results obtained in all three injections were close to each other and within acceptable limits. The glass transition temperature of the polymer was determined to be a Tg of 60°C. The thermodynamic data calculated for the injection of different amounts of probes were close to each other.http://dx.doi.org/10.1155/2019/5623873
collection DOAJ
language English
format Article
sources DOAJ
author Mustafa Hamdi Karagöz
spellingShingle Mustafa Hamdi Karagöz
Investigation of the Specific Retention Volume of the Probe Volume and the Effects on the Polymer-Probe System by Inverse Gas Chromatography
International Journal of Polymer Science
author_facet Mustafa Hamdi Karagöz
author_sort Mustafa Hamdi Karagöz
title Investigation of the Specific Retention Volume of the Probe Volume and the Effects on the Polymer-Probe System by Inverse Gas Chromatography
title_short Investigation of the Specific Retention Volume of the Probe Volume and the Effects on the Polymer-Probe System by Inverse Gas Chromatography
title_full Investigation of the Specific Retention Volume of the Probe Volume and the Effects on the Polymer-Probe System by Inverse Gas Chromatography
title_fullStr Investigation of the Specific Retention Volume of the Probe Volume and the Effects on the Polymer-Probe System by Inverse Gas Chromatography
title_full_unstemmed Investigation of the Specific Retention Volume of the Probe Volume and the Effects on the Polymer-Probe System by Inverse Gas Chromatography
title_sort investigation of the specific retention volume of the probe volume and the effects on the polymer-probe system by inverse gas chromatography
publisher Hindawi Limited
series International Journal of Polymer Science
issn 1687-9422
1687-9430
publishDate 2019-01-01
description In this study, the effects of probe quantities on retention volume and the physical and thermodynamic results of polymer-probe systems were investigated. For this purpose, by using inverse gas chromatographic method. Alcohols and alkanes with different chemical and physical properties were injected as probes on homopolymer (2-cyclohexylidene-1,3-dioxolane-4-yl-methyl methacrylate) (CHMMA). Probe quantities of 0.3, 0.6, and 0.9 μl were selected, and an injection was made at every 10°C between 40 and 150°C. In addition, 3 μl volume probes were tried but reproducible results were not obtained in these volumes and the detector was observed to be out of order after several injections. It has been observed that the specific retention volume of alcohols and alkanes partially increased by increasing the injection amount. A linear relationship was observed between probe quantities and specific retention volume. This linear relationship is apparent from the specific retention volume values, where the probes are independent of the physical and chemical structures. It was observed that the results obtained in all three injections were close to each other and within acceptable limits. The glass transition temperature of the polymer was determined to be a Tg of 60°C. The thermodynamic data calculated for the injection of different amounts of probes were close to each other.
url http://dx.doi.org/10.1155/2019/5623873
work_keys_str_mv AT mustafahamdikaragoz investigationofthespecificretentionvolumeoftheprobevolumeandtheeffectsonthepolymerprobesystembyinversegaschromatography
_version_ 1725073172354564096