A 3D Scanning System for Inverse Analysis of Moist Biological Samples: Design and Validation Using Tendon Fascicle Bundles
In this article, we present the design and validation of a non-contact scanning system for the development of a three-dimensional (3D) model of moist biological samples. Due to the irregular shapes and low stiffness of soft tissue samples, the use of a non-contact, reliable geometry scanning system...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2020-07-01
|
Series: | Sensors |
Subjects: | |
Online Access: | https://www.mdpi.com/1424-8220/20/14/3847 |
id |
doaj-0d49728caf954aa29240e73477c008b6 |
---|---|
record_format |
Article |
spelling |
doaj-0d49728caf954aa29240e73477c008b62020-11-25T03:25:49ZengMDPI AGSensors1424-82202020-07-01203847384710.3390/s20143847A 3D Scanning System for Inverse Analysis of Moist Biological Samples: Design and Validation Using Tendon Fascicle BundlesSylwia Dabrowska0Martyna Ekiert1Kaja Wojcik2Marek Kalemba3Andrzej Mlyniec4Faculty of Mechanical Engineering and Robotics, AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow, PolandFaculty of Mechanical Engineering and Robotics, AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow, PolandFaculty of Mechanical Engineering and Robotics, AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow, PolandFaculty of Mechanical Engineering and Robotics, AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow, PolandFaculty of Mechanical Engineering and Robotics, AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow, PolandIn this article, we present the design and validation of a non-contact scanning system for the development of a three-dimensional (3D) model of moist biological samples. Due to the irregular shapes and low stiffness of soft tissue samples, the use of a non-contact, reliable geometry scanning system with good accuracy and repeatability is required. We propose a reliable 3D scanning system consisting of a blue light profile sensor, stationary and rotating frames with stepper motors, gears and a five-phase stepping motor unit, single-axis robot, control system, and replaceable sample grips, which once mounted onto the sample, are used for both scanning and mechanical tests. The proposed system was validated by comparison of the cross-sectional areas calculated based on 3D models, digital caliper, and vision-based methods. Validation was done on regularly-shaped samples, a wooden twig, as well as tendon fascicle bundles. The 3D profiles were used for the development of the 3D computational model of the sample, including surface concavities. Our system allowed for 3D model development of samples with a relative error of less than 1.2% and high repeatability in approximately three minutes. This was crucial for the extraction of the mechanical properties and subsequent inverse analysis, enabling the calibration of complex material models.https://www.mdpi.com/1424-8220/20/14/3847non-contact measurementthree-dimensional imagingtendontendon fascicle bundles3D modelsoft tissues |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Sylwia Dabrowska Martyna Ekiert Kaja Wojcik Marek Kalemba Andrzej Mlyniec |
spellingShingle |
Sylwia Dabrowska Martyna Ekiert Kaja Wojcik Marek Kalemba Andrzej Mlyniec A 3D Scanning System for Inverse Analysis of Moist Biological Samples: Design and Validation Using Tendon Fascicle Bundles Sensors non-contact measurement three-dimensional imaging tendon tendon fascicle bundles 3D model soft tissues |
author_facet |
Sylwia Dabrowska Martyna Ekiert Kaja Wojcik Marek Kalemba Andrzej Mlyniec |
author_sort |
Sylwia Dabrowska |
title |
A 3D Scanning System for Inverse Analysis of Moist Biological Samples: Design and Validation Using Tendon Fascicle Bundles |
title_short |
A 3D Scanning System for Inverse Analysis of Moist Biological Samples: Design and Validation Using Tendon Fascicle Bundles |
title_full |
A 3D Scanning System for Inverse Analysis of Moist Biological Samples: Design and Validation Using Tendon Fascicle Bundles |
title_fullStr |
A 3D Scanning System for Inverse Analysis of Moist Biological Samples: Design and Validation Using Tendon Fascicle Bundles |
title_full_unstemmed |
A 3D Scanning System for Inverse Analysis of Moist Biological Samples: Design and Validation Using Tendon Fascicle Bundles |
title_sort |
3d scanning system for inverse analysis of moist biological samples: design and validation using tendon fascicle bundles |
publisher |
MDPI AG |
series |
Sensors |
issn |
1424-8220 |
publishDate |
2020-07-01 |
description |
In this article, we present the design and validation of a non-contact scanning system for the development of a three-dimensional (3D) model of moist biological samples. Due to the irregular shapes and low stiffness of soft tissue samples, the use of a non-contact, reliable geometry scanning system with good accuracy and repeatability is required. We propose a reliable 3D scanning system consisting of a blue light profile sensor, stationary and rotating frames with stepper motors, gears and a five-phase stepping motor unit, single-axis robot, control system, and replaceable sample grips, which once mounted onto the sample, are used for both scanning and mechanical tests. The proposed system was validated by comparison of the cross-sectional areas calculated based on 3D models, digital caliper, and vision-based methods. Validation was done on regularly-shaped samples, a wooden twig, as well as tendon fascicle bundles. The 3D profiles were used for the development of the 3D computational model of the sample, including surface concavities. Our system allowed for 3D model development of samples with a relative error of less than 1.2% and high repeatability in approximately three minutes. This was crucial for the extraction of the mechanical properties and subsequent inverse analysis, enabling the calibration of complex material models. |
topic |
non-contact measurement three-dimensional imaging tendon tendon fascicle bundles 3D model soft tissues |
url |
https://www.mdpi.com/1424-8220/20/14/3847 |
work_keys_str_mv |
AT sylwiadabrowska a3dscanningsystemforinverseanalysisofmoistbiologicalsamplesdesignandvalidationusingtendonfasciclebundles AT martynaekiert a3dscanningsystemforinverseanalysisofmoistbiologicalsamplesdesignandvalidationusingtendonfasciclebundles AT kajawojcik a3dscanningsystemforinverseanalysisofmoistbiologicalsamplesdesignandvalidationusingtendonfasciclebundles AT marekkalemba a3dscanningsystemforinverseanalysisofmoistbiologicalsamplesdesignandvalidationusingtendonfasciclebundles AT andrzejmlyniec a3dscanningsystemforinverseanalysisofmoistbiologicalsamplesdesignandvalidationusingtendonfasciclebundles AT sylwiadabrowska 3dscanningsystemforinverseanalysisofmoistbiologicalsamplesdesignandvalidationusingtendonfasciclebundles AT martynaekiert 3dscanningsystemforinverseanalysisofmoistbiologicalsamplesdesignandvalidationusingtendonfasciclebundles AT kajawojcik 3dscanningsystemforinverseanalysisofmoistbiologicalsamplesdesignandvalidationusingtendonfasciclebundles AT marekkalemba 3dscanningsystemforinverseanalysisofmoistbiologicalsamplesdesignandvalidationusingtendonfasciclebundles AT andrzejmlyniec 3dscanningsystemforinverseanalysisofmoistbiologicalsamplesdesignandvalidationusingtendonfasciclebundles |
_version_ |
1724595525388337152 |