Continuous, real-time monitoring of neonatal position and temperature during Kangaroo Mother Care using a wearable sensor: a techno-feasibility pilot study

Abstract Background Remote biomonitoring of vital parameters in hospitals and homes has the potential to improve coverage and quality of maternal and neonatal health. Wearable sensors coupled with modern information and communication technology now offer an opportunity to monitor temperatures and ka...

Full description

Bibliographic Details
Main Authors: Suman Rao, Prashanth Thankachan, Bharadwaj Amrutur, Maryann Washington, Prem K. Mony
Format: Article
Language:English
Published: BMC 2018-05-01
Series:Pilot and Feasibility Studies
Subjects:
Online Access:http://link.springer.com/article/10.1186/s40814-018-0293-5
id doaj-0cea492456224174872ea45561f70f6a
record_format Article
spelling doaj-0cea492456224174872ea45561f70f6a2020-11-25T02:47:28ZengBMCPilot and Feasibility Studies2055-57842018-05-01411710.1186/s40814-018-0293-5Continuous, real-time monitoring of neonatal position and temperature during Kangaroo Mother Care using a wearable sensor: a techno-feasibility pilot studySuman Rao0Prashanth Thankachan1Bharadwaj Amrutur2Maryann Washington3Prem K. Mony4Department of Neonatology, St John’s Medical College Hospital, St John’s National Academy of Health SciencesDivision of Epidemiology and Population Health, St John’s Research Institute, St John’s National Academy of Health SciencesRobert Bosch Center for Cyber Physical Systems, Indian Institute of ScienceDivision of Epidemiology and Population Health, St John’s Research Institute, St John’s National Academy of Health SciencesDivision of Epidemiology and Population Health, St John’s Research Institute, St John’s National Academy of Health SciencesAbstract Background Remote biomonitoring of vital parameters in hospitals and homes has the potential to improve coverage and quality of maternal and neonatal health. Wearable sensors coupled with modern information and communication technology now offer an opportunity to monitor temperatures and kangaroo mother care (KMC) adherence in a continuous and real-time manner remotely for several days’ duration in hospital and home settings. Using an innovative remote biomonitoring device to measure both temperature and baby position, we undertook a techno-feasibility study in preparation for a clinical trial. Methods We designed and developed a wearable sensor for tracking KMC adherence and neonatal temperature, using social innovation design principles. After screening mother-infant dyads using clinical and logistic eligibility criteria, we piloted this wearable sensor along with a gateway device and the commercial cellular network. The dyads were recruited during hospitalization and followed up in the hospital and home phases for several days. Simple descriptive statistical analysis was undertaken. Results Recruitment rate was 50% (6/12), and consenting rate was 83% (5/6) during a 2-month period. These five neonates contributed a total of 39 study days (15 hospital days and 24 home days). Their mean [± standard deviation (S.D.)] birth weight was 1490 (± 244) g. The mean (± S.D.) of the vital signs for the five babies was temperature [36.5 °C (± 0.3)], heart rate [146.5/min (± 14)], and oxygen saturation [94% (± 4)]. No severe or moderate side-effects were noted; one baby developed mild dermatitis under the device that was transient and self-limiting, yielding an incidence proportion of 20% and incidence rate of 2.6/100 person-days. None of the mothers reported any discomfort with the use of the device. Temperatures detected from 81 paired readings revealed that those from the wearable sensor were 0.2 °C lower than those detected by clinical thermometers [36.4 (± 0.7) vs 36.6 (± 0.3); < 0.001]. There was also iterative feedback that was useful for hardware and software design specifications of the wearable sensor, the gateway device, and the analytics platform. Lastly, lessons were learnt with regard to the logistics of research team interactions with healthcare professionals and study participants during the hospitalization and post-discharge home phases of the study. Conclusions The pilot study has shown that it is feasible and acceptable to track KMC adherence as well as maternal and newborn temperatures in a potentially safe manner on a real-time mode for several days’ duration during hospitalization and home phases. The pilot has also helped inform modifications in clinical monitoring, technological modifications, and logistics planning in preparation for the definitive clinical trial. Trial registration Clinical Trials Registry of India, CTRI/2017/09/009789http://link.springer.com/article/10.1186/s40814-018-0293-5Kangaroo mother caremHealthMonitoringNeonatal healthTemperatureVital
collection DOAJ
language English
format Article
sources DOAJ
author Suman Rao
Prashanth Thankachan
Bharadwaj Amrutur
Maryann Washington
Prem K. Mony
spellingShingle Suman Rao
Prashanth Thankachan
Bharadwaj Amrutur
Maryann Washington
Prem K. Mony
Continuous, real-time monitoring of neonatal position and temperature during Kangaroo Mother Care using a wearable sensor: a techno-feasibility pilot study
Pilot and Feasibility Studies
Kangaroo mother care
mHealth
Monitoring
Neonatal health
Temperature
Vital
author_facet Suman Rao
Prashanth Thankachan
Bharadwaj Amrutur
Maryann Washington
Prem K. Mony
author_sort Suman Rao
title Continuous, real-time monitoring of neonatal position and temperature during Kangaroo Mother Care using a wearable sensor: a techno-feasibility pilot study
title_short Continuous, real-time monitoring of neonatal position and temperature during Kangaroo Mother Care using a wearable sensor: a techno-feasibility pilot study
title_full Continuous, real-time monitoring of neonatal position and temperature during Kangaroo Mother Care using a wearable sensor: a techno-feasibility pilot study
title_fullStr Continuous, real-time monitoring of neonatal position and temperature during Kangaroo Mother Care using a wearable sensor: a techno-feasibility pilot study
title_full_unstemmed Continuous, real-time monitoring of neonatal position and temperature during Kangaroo Mother Care using a wearable sensor: a techno-feasibility pilot study
title_sort continuous, real-time monitoring of neonatal position and temperature during kangaroo mother care using a wearable sensor: a techno-feasibility pilot study
publisher BMC
series Pilot and Feasibility Studies
issn 2055-5784
publishDate 2018-05-01
description Abstract Background Remote biomonitoring of vital parameters in hospitals and homes has the potential to improve coverage and quality of maternal and neonatal health. Wearable sensors coupled with modern information and communication technology now offer an opportunity to monitor temperatures and kangaroo mother care (KMC) adherence in a continuous and real-time manner remotely for several days’ duration in hospital and home settings. Using an innovative remote biomonitoring device to measure both temperature and baby position, we undertook a techno-feasibility study in preparation for a clinical trial. Methods We designed and developed a wearable sensor for tracking KMC adherence and neonatal temperature, using social innovation design principles. After screening mother-infant dyads using clinical and logistic eligibility criteria, we piloted this wearable sensor along with a gateway device and the commercial cellular network. The dyads were recruited during hospitalization and followed up in the hospital and home phases for several days. Simple descriptive statistical analysis was undertaken. Results Recruitment rate was 50% (6/12), and consenting rate was 83% (5/6) during a 2-month period. These five neonates contributed a total of 39 study days (15 hospital days and 24 home days). Their mean [± standard deviation (S.D.)] birth weight was 1490 (± 244) g. The mean (± S.D.) of the vital signs for the five babies was temperature [36.5 °C (± 0.3)], heart rate [146.5/min (± 14)], and oxygen saturation [94% (± 4)]. No severe or moderate side-effects were noted; one baby developed mild dermatitis under the device that was transient and self-limiting, yielding an incidence proportion of 20% and incidence rate of 2.6/100 person-days. None of the mothers reported any discomfort with the use of the device. Temperatures detected from 81 paired readings revealed that those from the wearable sensor were 0.2 °C lower than those detected by clinical thermometers [36.4 (± 0.7) vs 36.6 (± 0.3); < 0.001]. There was also iterative feedback that was useful for hardware and software design specifications of the wearable sensor, the gateway device, and the analytics platform. Lastly, lessons were learnt with regard to the logistics of research team interactions with healthcare professionals and study participants during the hospitalization and post-discharge home phases of the study. Conclusions The pilot study has shown that it is feasible and acceptable to track KMC adherence as well as maternal and newborn temperatures in a potentially safe manner on a real-time mode for several days’ duration during hospitalization and home phases. The pilot has also helped inform modifications in clinical monitoring, technological modifications, and logistics planning in preparation for the definitive clinical trial. Trial registration Clinical Trials Registry of India, CTRI/2017/09/009789
topic Kangaroo mother care
mHealth
Monitoring
Neonatal health
Temperature
Vital
url http://link.springer.com/article/10.1186/s40814-018-0293-5
work_keys_str_mv AT sumanrao continuousrealtimemonitoringofneonatalpositionandtemperatureduringkangaroomothercareusingawearablesensoratechnofeasibilitypilotstudy
AT prashanththankachan continuousrealtimemonitoringofneonatalpositionandtemperatureduringkangaroomothercareusingawearablesensoratechnofeasibilitypilotstudy
AT bharadwajamrutur continuousrealtimemonitoringofneonatalpositionandtemperatureduringkangaroomothercareusingawearablesensoratechnofeasibilitypilotstudy
AT maryannwashington continuousrealtimemonitoringofneonatalpositionandtemperatureduringkangaroomothercareusingawearablesensoratechnofeasibilitypilotstudy
AT premkmony continuousrealtimemonitoringofneonatalpositionandtemperatureduringkangaroomothercareusingawearablesensoratechnofeasibilitypilotstudy
_version_ 1724753297629249536