Preliminary results on the effects of orthopedic implant stiffness fixed to the cut end of the femur on the stress at the stump-prosthetic interface

A lot of trans-femoral amputation patients experience skin breakdown due to the pressures and shear stresses in the stump-prosthesis interface. In this study, a finite element model was employed to investigate the stresses at the stump interface in the case of an orthopedic implant fixed to the cut...

Full description

Bibliographic Details
Main Authors: Ismail Boudjemaa, A. Sahli, A. Benkhettou, S. Benbarek
Format: Article
Language:English
Published: Gruppo Italiano Frattura 2021-06-01
Series:Frattura ed Integrità Strutturale
Subjects:
Online Access:https://www.fracturae.com/index.php/fis/article/view/3074
id doaj-0c9dce2066534a70a9b8a87bf8b87744
record_format Article
spelling doaj-0c9dce2066534a70a9b8a87bf8b877442021-10-04T10:34:45ZengGruppo Italiano FratturaFrattura ed Integrità Strutturale1971-89932021-06-011557Preliminary results on the effects of orthopedic implant stiffness fixed to the cut end of the femur on the stress at the stump-prosthetic interfaceIsmail Boudjemaa0A. Sahli1A. Benkhettou2S. Benbarek3Department of Mechanical Engineering, Laboratory Mechanics Physics of Materials (LMPM), University of SidiBel Abbes, BP 89, cite Ben M’hidi, SidiBel Abbes, 22000, AlgeriaDepartment of Mechanical Engineering, Laboratory Mechanics Physics of Materials (LMPM), University of SidiBel Abbes, BP 89, cite Ben M’hidi, SidiBel Abbes, 22000, AlgeriaDepartment of Mechanical Engineering, Laboratory Mechanics Physics of Materials (LMPM), University of SidiBel Abbes, BP 89, cite Ben M’hidi, SidiBel Abbes, 22000, AlgeriaDepartment of Mechanical Engineering, Laboratory Mechanics Physics of Materials (LMPM), University of SidiBel Abbes, BP 89, cite Ben M’hidi, SidiBel Abbes, 22000, Algeria A lot of trans-femoral amputation patients experience skin breakdown due to the pressures and shear stresses in the stump-prosthesis interface. In this study, a finite element model was employed to investigate the stresses at the stump interface in the case of an orthopedic implant fixed to the cut end of the femur. By changing the stiffness of this implant, we aim to see how the stiffness of this implant affects the stresses in the interface between the amputated limb and the prosthesis. To find out the effects of implant stiffness, five values for the elastic modulus, ranging from 0.1 to 0.5 Mpa, with an interval of 0.1 Mpa were employed in the implant structure of the FE model. Obtained results show that the implant played important role in reducing the stresses at the stump-prosthesis interface where the contact pressure did not exceed 53 Kpa and 17.3 Kpa for shear stress in the stiffer case of an implant, while the contact pressure in the case of femur without implant exceeded 79Kpa and 42 Kpa for shear stress. We also noted that the intensity of the contact pressure and the shear stress is proportional to the stiffness of the implant, as the greater the implant stiffness, the higher the peak of these stresses. https://www.fracturae.com/index.php/fis/article/view/3074ProsthesisStump interfaceStiffnessContacts stressesImplant
collection DOAJ
language English
format Article
sources DOAJ
author Ismail Boudjemaa
A. Sahli
A. Benkhettou
S. Benbarek
spellingShingle Ismail Boudjemaa
A. Sahli
A. Benkhettou
S. Benbarek
Preliminary results on the effects of orthopedic implant stiffness fixed to the cut end of the femur on the stress at the stump-prosthetic interface
Frattura ed Integrità Strutturale
Prosthesis
Stump interface
Stiffness
Contacts stresses
Implant
author_facet Ismail Boudjemaa
A. Sahli
A. Benkhettou
S. Benbarek
author_sort Ismail Boudjemaa
title Preliminary results on the effects of orthopedic implant stiffness fixed to the cut end of the femur on the stress at the stump-prosthetic interface
title_short Preliminary results on the effects of orthopedic implant stiffness fixed to the cut end of the femur on the stress at the stump-prosthetic interface
title_full Preliminary results on the effects of orthopedic implant stiffness fixed to the cut end of the femur on the stress at the stump-prosthetic interface
title_fullStr Preliminary results on the effects of orthopedic implant stiffness fixed to the cut end of the femur on the stress at the stump-prosthetic interface
title_full_unstemmed Preliminary results on the effects of orthopedic implant stiffness fixed to the cut end of the femur on the stress at the stump-prosthetic interface
title_sort preliminary results on the effects of orthopedic implant stiffness fixed to the cut end of the femur on the stress at the stump-prosthetic interface
publisher Gruppo Italiano Frattura
series Frattura ed Integrità Strutturale
issn 1971-8993
publishDate 2021-06-01
description A lot of trans-femoral amputation patients experience skin breakdown due to the pressures and shear stresses in the stump-prosthesis interface. In this study, a finite element model was employed to investigate the stresses at the stump interface in the case of an orthopedic implant fixed to the cut end of the femur. By changing the stiffness of this implant, we aim to see how the stiffness of this implant affects the stresses in the interface between the amputated limb and the prosthesis. To find out the effects of implant stiffness, five values for the elastic modulus, ranging from 0.1 to 0.5 Mpa, with an interval of 0.1 Mpa were employed in the implant structure of the FE model. Obtained results show that the implant played important role in reducing the stresses at the stump-prosthesis interface where the contact pressure did not exceed 53 Kpa and 17.3 Kpa for shear stress in the stiffer case of an implant, while the contact pressure in the case of femur without implant exceeded 79Kpa and 42 Kpa for shear stress. We also noted that the intensity of the contact pressure and the shear stress is proportional to the stiffness of the implant, as the greater the implant stiffness, the higher the peak of these stresses.
topic Prosthesis
Stump interface
Stiffness
Contacts stresses
Implant
url https://www.fracturae.com/index.php/fis/article/view/3074
work_keys_str_mv AT ismailboudjemaa preliminaryresultsontheeffectsoforthopedicimplantstiffnessfixedtothecutendofthefemuronthestressatthestumpprostheticinterface
AT asahli preliminaryresultsontheeffectsoforthopedicimplantstiffnessfixedtothecutendofthefemuronthestressatthestumpprostheticinterface
AT abenkhettou preliminaryresultsontheeffectsoforthopedicimplantstiffnessfixedtothecutendofthefemuronthestressatthestumpprostheticinterface
AT sbenbarek preliminaryresultsontheeffectsoforthopedicimplantstiffnessfixedtothecutendofthefemuronthestressatthestumpprostheticinterface
_version_ 1716844180013056000