COMPARATIVE ANALYSIS AND EVALUATION OF PHYSICAL AND MECHANICAL PROPERTIES OF A-SILICONE FLEXIBLE CONSTRUCTION MATERIALS

The aim of the study was to investigate the physical and mechanical properties of A-silicone materials «PM-S», «PM-S Extra» and «UfI Gel P» (Voco) in a comparative perspective. Bond strength of the material meets the requirements (Н ≥4,0 kg/cm2). That parameter was investigated on acrylic basis a...

Full description

Bibliographic Details
Main Authors: I.V. Yanishen, S.A. German
Format: Article
Language:English
Published: Ukrainian Medical Stomatological Academy 2015-03-01
Series:Український стоматологічний альманах
Subjects:
Online Access:https://dental-almanac.org/index.php/journal/article/view/72
id doaj-0c5fc9cf36b24200983fdfd3ff445534
record_format Article
spelling doaj-0c5fc9cf36b24200983fdfd3ff4455342020-11-25T00:18:33ZengUkrainian Medical Stomatological Academy Український стоматологічний альманах2409-02552410-14272015-03-015273072COMPARATIVE ANALYSIS AND EVALUATION OF PHYSICAL AND MECHANICAL PROPERTIES OF A-SILICONE FLEXIBLE CONSTRUCTION MATERIALSI.V. Yanishen0S.A. German1Kharkiv National Medical UniversityKharkiv National Medical UniversityThe aim of the study was to investigate the physical and mechanical properties of A-silicone materials «PM-S», «PM-S Extra» and «UfI Gel P» (Voco) in a comparative perspective. Bond strength of the material meets the requirements (Н ≥4,0 kg/cm2). That parameter was investigated on acrylic basis and ranged (6,9 ± 0,2) kg/cm2. We determined that bond strength of material «PM-S Extra», which was (6,9 ± 0,2) kg/cm2 was somewhat smaller than that of the material «Ufi Gel P»- (9,2 ± 0.2) kg/cm2 and significantly (p <0.01) higher than that of the material «PM-S» - (5,3 ± 0,2) kg/cm2. Elongation of experimental samples (FP), which indirectly characterizes the elasticity of dental pads for claspless fixation, made of tested materials was in the range (32,3 ÷ 41,7)%. The property of recovery compressive deformation (IB%) of all studied materials ranges (99,90 ÷ 99,95)%, which corresponds to the regulatory requirements (IVS ≥ 96,5%); The consistency compound index (D, mm) of studied A-silicone materials ranges 23,2 ÷ 32,5%, and compliance ≥ 23 mm. We found out that the indicator of compound consistency of material «PM-S Extra», which was (23,9 ± 0,3) mm, greater than the material «PM-S» - (23,2 ± 0,1)% and significantly (p <0 05) smaller than that of the material «Ufi Gel P» - (32,5 + 1,4)%. The index of relative compression set (S, %) of the materials for the manufacture of lining dentures ranges (34,1 ÷ 40,9)%, and compliance (20,0≥S)%; Compressive deformation of the material «PM-S Extra» - (34,1 ± 1,2)% was the lowest value: slightly lower (p <0.05) than that of the material «Ufi Gel P» - (38,3 ± 0,8%) and lower (p <0.05) than that of the material "PM-S" which was (40,9 ± 1.7)%. The findings suggest that, in general, domestic material "PM-S Extra" its physical and mechanical properties fully meets the requirements of this class of dental materials. «PM-S Extra» is characterized by a satisfactory level of reproducibility of standard features that have more stable properties in a clinical setting. Comparative characteristics showed that the material "PM-S Extra" in its main indicators is not inferior to imported materials «Ufi Gel P». It differs from the prototype "PM-S" and has more solid and hard consistency, which makes it possible to fix the removable partial dentures without clasp.https://dental-almanac.org/index.php/journal/article/view/72A-silicone material, physical and mechanical properties, removable partial dentures, claspless fixation.
collection DOAJ
language English
format Article
sources DOAJ
author I.V. Yanishen
S.A. German
spellingShingle I.V. Yanishen
S.A. German
COMPARATIVE ANALYSIS AND EVALUATION OF PHYSICAL AND MECHANICAL PROPERTIES OF A-SILICONE FLEXIBLE CONSTRUCTION MATERIALS
Український стоматологічний альманах
A-silicone material, physical and mechanical properties, removable partial dentures, claspless fixation.
author_facet I.V. Yanishen
S.A. German
author_sort I.V. Yanishen
title COMPARATIVE ANALYSIS AND EVALUATION OF PHYSICAL AND MECHANICAL PROPERTIES OF A-SILICONE FLEXIBLE CONSTRUCTION MATERIALS
title_short COMPARATIVE ANALYSIS AND EVALUATION OF PHYSICAL AND MECHANICAL PROPERTIES OF A-SILICONE FLEXIBLE CONSTRUCTION MATERIALS
title_full COMPARATIVE ANALYSIS AND EVALUATION OF PHYSICAL AND MECHANICAL PROPERTIES OF A-SILICONE FLEXIBLE CONSTRUCTION MATERIALS
title_fullStr COMPARATIVE ANALYSIS AND EVALUATION OF PHYSICAL AND MECHANICAL PROPERTIES OF A-SILICONE FLEXIBLE CONSTRUCTION MATERIALS
title_full_unstemmed COMPARATIVE ANALYSIS AND EVALUATION OF PHYSICAL AND MECHANICAL PROPERTIES OF A-SILICONE FLEXIBLE CONSTRUCTION MATERIALS
title_sort comparative analysis and evaluation of physical and mechanical properties of a-silicone flexible construction materials
publisher Ukrainian Medical Stomatological Academy
series Український стоматологічний альманах
issn 2409-0255
2410-1427
publishDate 2015-03-01
description The aim of the study was to investigate the physical and mechanical properties of A-silicone materials «PM-S», «PM-S Extra» and «UfI Gel P» (Voco) in a comparative perspective. Bond strength of the material meets the requirements (Н ≥4,0 kg/cm2). That parameter was investigated on acrylic basis and ranged (6,9 ± 0,2) kg/cm2. We determined that bond strength of material «PM-S Extra», which was (6,9 ± 0,2) kg/cm2 was somewhat smaller than that of the material «Ufi Gel P»- (9,2 ± 0.2) kg/cm2 and significantly (p <0.01) higher than that of the material «PM-S» - (5,3 ± 0,2) kg/cm2. Elongation of experimental samples (FP), which indirectly characterizes the elasticity of dental pads for claspless fixation, made of tested materials was in the range (32,3 ÷ 41,7)%. The property of recovery compressive deformation (IB%) of all studied materials ranges (99,90 ÷ 99,95)%, which corresponds to the regulatory requirements (IVS ≥ 96,5%); The consistency compound index (D, mm) of studied A-silicone materials ranges 23,2 ÷ 32,5%, and compliance ≥ 23 mm. We found out that the indicator of compound consistency of material «PM-S Extra», which was (23,9 ± 0,3) mm, greater than the material «PM-S» - (23,2 ± 0,1)% and significantly (p <0 05) smaller than that of the material «Ufi Gel P» - (32,5 + 1,4)%. The index of relative compression set (S, %) of the materials for the manufacture of lining dentures ranges (34,1 ÷ 40,9)%, and compliance (20,0≥S)%; Compressive deformation of the material «PM-S Extra» - (34,1 ± 1,2)% was the lowest value: slightly lower (p <0.05) than that of the material «Ufi Gel P» - (38,3 ± 0,8%) and lower (p <0.05) than that of the material "PM-S" which was (40,9 ± 1.7)%. The findings suggest that, in general, domestic material "PM-S Extra" its physical and mechanical properties fully meets the requirements of this class of dental materials. «PM-S Extra» is characterized by a satisfactory level of reproducibility of standard features that have more stable properties in a clinical setting. Comparative characteristics showed that the material "PM-S Extra" in its main indicators is not inferior to imported materials «Ufi Gel P». It differs from the prototype "PM-S" and has more solid and hard consistency, which makes it possible to fix the removable partial dentures without clasp.
topic A-silicone material, physical and mechanical properties, removable partial dentures, claspless fixation.
url https://dental-almanac.org/index.php/journal/article/view/72
work_keys_str_mv AT ivyanishen comparativeanalysisandevaluationofphysicalandmechanicalpropertiesofasiliconeflexibleconstructionmaterials
AT sagerman comparativeanalysisandevaluationofphysicalandmechanicalpropertiesofasiliconeflexibleconstructionmaterials
_version_ 1725375955648643072