Monitoring of Anesthesia by Bispectral Analysis of EEG Signals

Background. In intensive care, monitoring the depth of anesthesia during surgical procedures is a key element in the success of the medical operation and postoperative recovery. However, despite the development of anesthesia thanks to technological and pharmacological advances, its side effects such...

Full description

Bibliographic Details
Main Author: Lamia Bouafif
Format: Article
Language:English
Published: Hindawi Limited 2021-01-01
Series:Computational and Mathematical Methods in Medicine
Online Access:http://dx.doi.org/10.1155/2021/9961998
id doaj-0c49fcb354dd4f4ca73b62a74bb0b132
record_format Article
spelling doaj-0c49fcb354dd4f4ca73b62a74bb0b1322021-10-04T01:58:11ZengHindawi LimitedComputational and Mathematical Methods in Medicine1748-67182021-01-01202110.1155/2021/9961998Monitoring of Anesthesia by Bispectral Analysis of EEG SignalsLamia Bouafif0National Institute of Biomedical Studies of Tunis-Image and Signal Processing Laboratory ENITBackground. In intensive care, monitoring the depth of anesthesia during surgical procedures is a key element in the success of the medical operation and postoperative recovery. However, despite the development of anesthesia thanks to technological and pharmacological advances, its side effects such as underdose or overdose of hypnotics remain a major problem. Observation and monitoring must combine clinical observations (loss of consciousness and reactivity) with tools for real-time measurement of changes in the depth of anesthesia. Methodology. In this work, we will develop a noninvasive method for calculating, monitoring, and controlling the depth of general anesthesia during surgery. The objective is to reduce the effects of pharmacological usage of hypnotics and to ensure better quality recovery. Thanks to the overall activity of sets of neurons in the brain, we have developed a BIS technique based on bispectral analysis of the electroencephalographic signal EEG. Discussion. By collecting the electrical voltages from the brain, we distinguish light sleep from deep sleep according to the values of the BIS indicator (ranging from 0 : sleep to 100 : wake) and also control it by acting on the dosage of propofol and sevoflurane. We showed that the BIS value must be maintained during the operation and the anesthesia at a value greater than 60. Conclusion. This study showed that the BIS technology led to an optimization of the anesthetic management, the adequacy of the hypnotic dosage, and a better postoperative recovery.http://dx.doi.org/10.1155/2021/9961998
collection DOAJ
language English
format Article
sources DOAJ
author Lamia Bouafif
spellingShingle Lamia Bouafif
Monitoring of Anesthesia by Bispectral Analysis of EEG Signals
Computational and Mathematical Methods in Medicine
author_facet Lamia Bouafif
author_sort Lamia Bouafif
title Monitoring of Anesthesia by Bispectral Analysis of EEG Signals
title_short Monitoring of Anesthesia by Bispectral Analysis of EEG Signals
title_full Monitoring of Anesthesia by Bispectral Analysis of EEG Signals
title_fullStr Monitoring of Anesthesia by Bispectral Analysis of EEG Signals
title_full_unstemmed Monitoring of Anesthesia by Bispectral Analysis of EEG Signals
title_sort monitoring of anesthesia by bispectral analysis of eeg signals
publisher Hindawi Limited
series Computational and Mathematical Methods in Medicine
issn 1748-6718
publishDate 2021-01-01
description Background. In intensive care, monitoring the depth of anesthesia during surgical procedures is a key element in the success of the medical operation and postoperative recovery. However, despite the development of anesthesia thanks to technological and pharmacological advances, its side effects such as underdose or overdose of hypnotics remain a major problem. Observation and monitoring must combine clinical observations (loss of consciousness and reactivity) with tools for real-time measurement of changes in the depth of anesthesia. Methodology. In this work, we will develop a noninvasive method for calculating, monitoring, and controlling the depth of general anesthesia during surgery. The objective is to reduce the effects of pharmacological usage of hypnotics and to ensure better quality recovery. Thanks to the overall activity of sets of neurons in the brain, we have developed a BIS technique based on bispectral analysis of the electroencephalographic signal EEG. Discussion. By collecting the electrical voltages from the brain, we distinguish light sleep from deep sleep according to the values of the BIS indicator (ranging from 0 : sleep to 100 : wake) and also control it by acting on the dosage of propofol and sevoflurane. We showed that the BIS value must be maintained during the operation and the anesthesia at a value greater than 60. Conclusion. This study showed that the BIS technology led to an optimization of the anesthetic management, the adequacy of the hypnotic dosage, and a better postoperative recovery.
url http://dx.doi.org/10.1155/2021/9961998
work_keys_str_mv AT lamiabouafif monitoringofanesthesiabybispectralanalysisofeegsignals
_version_ 1716844710871433216