Distance protection based on parameter identification considering transformer characteristics

The distance protection method with parameter identification can distinguish internal fault from external fault correctly and avoid the transient overreach effectively based on the accurate secondary signal data. However, due to the limitation of the frequency band of the electromagnetic transformer...

Full description

Bibliographic Details
Main Authors: Zhiqin Zheng, Baozhu Shao, Tongwei Yu, Yakun Liu, Guobing Song
Format: Article
Language:English
Published: Wiley 2018-10-01
Series:The Journal of Engineering
Subjects:
Online Access:https://digital-library.theiet.org/content/journals/10.1049/joe.2018.8818
id doaj-0c05aca31d8f4a26a36cbf2a046f51d1
record_format Article
spelling doaj-0c05aca31d8f4a26a36cbf2a046f51d12021-04-02T11:06:36ZengWileyThe Journal of Engineering2051-33052018-10-0110.1049/joe.2018.8818JOE.2018.8818Distance protection based on parameter identification considering transformer characteristicsZhiqin Zheng0Baozhu Shao1Tongwei Yu2Yakun Liu3Guobing Song4Liaoning Electric Power Research InstituteLiaoning Electric Power Research InstituteLiaoning Electric Power Research InstituteCollege of Electrical Engineering, Xi'an Jiaotong UniversityCollege of Electrical Engineering, Xi'an Jiaotong UniversityThe distance protection method with parameter identification can distinguish internal fault from external fault correctly and avoid the transient overreach effectively based on the accurate secondary signal data. However, due to the limitation of the frequency band of the electromagnetic transformer, the secondary signal distortion is caused when the transient signal is transmitted, which limits the application of the parameter identification principle. Here, a matching method of line model and transformer type for relay protection is proposed. Analysed the appropriate frequency band of line model and transformer linear transfer frequency band and the electrical signal beyond their intersection should be filtered out. The simulation results show that this method improves the accuracy of the operation. This method not only makes sense to the practical application of distance protection based on the principle of parameter identification, but also has some reference value to other engineering applications.https://digital-library.theiet.org/content/journals/10.1049/joe.2018.8818parameter estimationrelay protectionpower system transientspower system faultsfault locationpower transformer protectiontransformer characteristicsdistance protection methodinternal faultexternal faultaccurate secondary signal dataelectromagnetic transformersecondary signal distortiontransient signalparameter identification principlematching methodline modelrelay protectionappropriate frequency bandtransformer linear transfer frequency bandelectrical signal
collection DOAJ
language English
format Article
sources DOAJ
author Zhiqin Zheng
Baozhu Shao
Tongwei Yu
Yakun Liu
Guobing Song
spellingShingle Zhiqin Zheng
Baozhu Shao
Tongwei Yu
Yakun Liu
Guobing Song
Distance protection based on parameter identification considering transformer characteristics
The Journal of Engineering
parameter estimation
relay protection
power system transients
power system faults
fault location
power transformer protection
transformer characteristics
distance protection method
internal fault
external fault
accurate secondary signal data
electromagnetic transformer
secondary signal distortion
transient signal
parameter identification principle
matching method
line model
relay protection
appropriate frequency band
transformer linear transfer frequency band
electrical signal
author_facet Zhiqin Zheng
Baozhu Shao
Tongwei Yu
Yakun Liu
Guobing Song
author_sort Zhiqin Zheng
title Distance protection based on parameter identification considering transformer characteristics
title_short Distance protection based on parameter identification considering transformer characteristics
title_full Distance protection based on parameter identification considering transformer characteristics
title_fullStr Distance protection based on parameter identification considering transformer characteristics
title_full_unstemmed Distance protection based on parameter identification considering transformer characteristics
title_sort distance protection based on parameter identification considering transformer characteristics
publisher Wiley
series The Journal of Engineering
issn 2051-3305
publishDate 2018-10-01
description The distance protection method with parameter identification can distinguish internal fault from external fault correctly and avoid the transient overreach effectively based on the accurate secondary signal data. However, due to the limitation of the frequency band of the electromagnetic transformer, the secondary signal distortion is caused when the transient signal is transmitted, which limits the application of the parameter identification principle. Here, a matching method of line model and transformer type for relay protection is proposed. Analysed the appropriate frequency band of line model and transformer linear transfer frequency band and the electrical signal beyond their intersection should be filtered out. The simulation results show that this method improves the accuracy of the operation. This method not only makes sense to the practical application of distance protection based on the principle of parameter identification, but also has some reference value to other engineering applications.
topic parameter estimation
relay protection
power system transients
power system faults
fault location
power transformer protection
transformer characteristics
distance protection method
internal fault
external fault
accurate secondary signal data
electromagnetic transformer
secondary signal distortion
transient signal
parameter identification principle
matching method
line model
relay protection
appropriate frequency band
transformer linear transfer frequency band
electrical signal
url https://digital-library.theiet.org/content/journals/10.1049/joe.2018.8818
work_keys_str_mv AT zhiqinzheng distanceprotectionbasedonparameteridentificationconsideringtransformercharacteristics
AT baozhushao distanceprotectionbasedonparameteridentificationconsideringtransformercharacteristics
AT tongweiyu distanceprotectionbasedonparameteridentificationconsideringtransformercharacteristics
AT yakunliu distanceprotectionbasedonparameteridentificationconsideringtransformercharacteristics
AT guobingsong distanceprotectionbasedonparameteridentificationconsideringtransformercharacteristics
_version_ 1724165631117361152