Distance protection based on parameter identification considering transformer characteristics
The distance protection method with parameter identification can distinguish internal fault from external fault correctly and avoid the transient overreach effectively based on the accurate secondary signal data. However, due to the limitation of the frequency band of the electromagnetic transformer...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2018-10-01
|
Series: | The Journal of Engineering |
Subjects: | |
Online Access: | https://digital-library.theiet.org/content/journals/10.1049/joe.2018.8818 |
id |
doaj-0c05aca31d8f4a26a36cbf2a046f51d1 |
---|---|
record_format |
Article |
spelling |
doaj-0c05aca31d8f4a26a36cbf2a046f51d12021-04-02T11:06:36ZengWileyThe Journal of Engineering2051-33052018-10-0110.1049/joe.2018.8818JOE.2018.8818Distance protection based on parameter identification considering transformer characteristicsZhiqin Zheng0Baozhu Shao1Tongwei Yu2Yakun Liu3Guobing Song4Liaoning Electric Power Research InstituteLiaoning Electric Power Research InstituteLiaoning Electric Power Research InstituteCollege of Electrical Engineering, Xi'an Jiaotong UniversityCollege of Electrical Engineering, Xi'an Jiaotong UniversityThe distance protection method with parameter identification can distinguish internal fault from external fault correctly and avoid the transient overreach effectively based on the accurate secondary signal data. However, due to the limitation of the frequency band of the electromagnetic transformer, the secondary signal distortion is caused when the transient signal is transmitted, which limits the application of the parameter identification principle. Here, a matching method of line model and transformer type for relay protection is proposed. Analysed the appropriate frequency band of line model and transformer linear transfer frequency band and the electrical signal beyond their intersection should be filtered out. The simulation results show that this method improves the accuracy of the operation. This method not only makes sense to the practical application of distance protection based on the principle of parameter identification, but also has some reference value to other engineering applications.https://digital-library.theiet.org/content/journals/10.1049/joe.2018.8818parameter estimationrelay protectionpower system transientspower system faultsfault locationpower transformer protectiontransformer characteristicsdistance protection methodinternal faultexternal faultaccurate secondary signal dataelectromagnetic transformersecondary signal distortiontransient signalparameter identification principlematching methodline modelrelay protectionappropriate frequency bandtransformer linear transfer frequency bandelectrical signal |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Zhiqin Zheng Baozhu Shao Tongwei Yu Yakun Liu Guobing Song |
spellingShingle |
Zhiqin Zheng Baozhu Shao Tongwei Yu Yakun Liu Guobing Song Distance protection based on parameter identification considering transformer characteristics The Journal of Engineering parameter estimation relay protection power system transients power system faults fault location power transformer protection transformer characteristics distance protection method internal fault external fault accurate secondary signal data electromagnetic transformer secondary signal distortion transient signal parameter identification principle matching method line model relay protection appropriate frequency band transformer linear transfer frequency band electrical signal |
author_facet |
Zhiqin Zheng Baozhu Shao Tongwei Yu Yakun Liu Guobing Song |
author_sort |
Zhiqin Zheng |
title |
Distance protection based on parameter identification considering transformer characteristics |
title_short |
Distance protection based on parameter identification considering transformer characteristics |
title_full |
Distance protection based on parameter identification considering transformer characteristics |
title_fullStr |
Distance protection based on parameter identification considering transformer characteristics |
title_full_unstemmed |
Distance protection based on parameter identification considering transformer characteristics |
title_sort |
distance protection based on parameter identification considering transformer characteristics |
publisher |
Wiley |
series |
The Journal of Engineering |
issn |
2051-3305 |
publishDate |
2018-10-01 |
description |
The distance protection method with parameter identification can distinguish internal fault from external fault correctly and avoid the transient overreach effectively based on the accurate secondary signal data. However, due to the limitation of the frequency band of the electromagnetic transformer, the secondary signal distortion is caused when the transient signal is transmitted, which limits the application of the parameter identification principle. Here, a matching method of line model and transformer type for relay protection is proposed. Analysed the appropriate frequency band of line model and transformer linear transfer frequency band and the electrical signal beyond their intersection should be filtered out. The simulation results show that this method improves the accuracy of the operation. This method not only makes sense to the practical application of distance protection based on the principle of parameter identification, but also has some reference value to other engineering applications. |
topic |
parameter estimation relay protection power system transients power system faults fault location power transformer protection transformer characteristics distance protection method internal fault external fault accurate secondary signal data electromagnetic transformer secondary signal distortion transient signal parameter identification principle matching method line model relay protection appropriate frequency band transformer linear transfer frequency band electrical signal |
url |
https://digital-library.theiet.org/content/journals/10.1049/joe.2018.8818 |
work_keys_str_mv |
AT zhiqinzheng distanceprotectionbasedonparameteridentificationconsideringtransformercharacteristics AT baozhushao distanceprotectionbasedonparameteridentificationconsideringtransformercharacteristics AT tongweiyu distanceprotectionbasedonparameteridentificationconsideringtransformercharacteristics AT yakunliu distanceprotectionbasedonparameteridentificationconsideringtransformercharacteristics AT guobingsong distanceprotectionbasedonparameteridentificationconsideringtransformercharacteristics |
_version_ |
1724165631117361152 |