Ionizing radiation influence on parameters of analog components of the master slice array МН2ХА030

Structured arrays and master slice arrays are often used to reduce cost, design and test time for radiation hardened analog integrated circuits. One of such master slice arrays is МН2ХА030, which uses bipolar and junction field-effect transistors. The purpose of this article is to estimate the effec...

Full description

Bibliographic Details
Main Authors: O. V. Dvornikov, V. A. Tchekhovski, V. L. Dziatlau, Y. D. Galkin, Nikolay N. Prokopenko
Format: Article
Language:Russian
Published: Educational institution «Belarusian State University of Informatics and Radioelectronics» 2021-07-01
Series:Doklady Belorusskogo gosudarstvennogo universiteta informatiki i radioèlektroniki
Subjects:
Online Access:https://doklady.bsuir.by/jour/article/view/3108
id doaj-0ba6b446cac44ad683a6bcf06d931b9b
record_format Article
spelling doaj-0ba6b446cac44ad683a6bcf06d931b9b2021-07-28T16:20:00ZrusEducational institution «Belarusian State University of Informatics and Radioelectronics»Doklady Belorusskogo gosudarstvennogo universiteta informatiki i radioèlektroniki1729-76482021-07-01194526010.35596/1729-7648-2021-19-4-52-601708Ionizing radiation influence on parameters of analog components of the master slice array МН2ХА030O. V. Dvornikov0V. A. Tchekhovski1V. L. Dziatlau2Y. D. Galkin3Nikolay N. Prokopenko4Minsk Research Instrument-Making Institute JSC (MNIPI JSC)Institute for Nuclear Problems of Belarusian State UniversityInstitute for Nuclear Problems of Belarusian State UniversityInstitute for Nuclear Problems of Belarusian State University; Belarusian State University of Informatics and RadioelectronicsDon State Technical UniversityStructured arrays and master slice arrays are often used to reduce cost, design and test time for radiation hardened analog integrated circuits. One of such master slice arrays is МН2ХА030, which uses bipolar and junction field-effect transistors. The purpose of this article is to estimate the effect of ionizing radiation on the parameters of the operational amplifier OAmp2 and comparators ADComp1 and ADComp3 created on the МН2ХА030 master slice array. Еhe results of measurements of analog components after exposure to 60Co gamma quanta with an absorbed dose of up to 700 krad and a fast electron fluence of up to 2.9·1015 el./cm2 with an energy of 6 MeV are presented. The OAmp2 operational amplifier provides a satisfactory level of basic static parameters (input current, offset voltage, voltage gain) at a fast electron fluence of up to 3.7·1014 el./cm2 with an energy of 6 MeV. There are a decrease in the voltage gain and an increase in the offset voltage at electron fluence of greater than 1015 el./cm2. The latter can be caused by a decrease in the efficiency of the common-mode signal feedback integrated into operational amplifier with a significant drop in current gain of bipolar transistors. All considered analog components provide a satisfactory level of basic static parameters at a fast electron fluence of up to 3.7·1014 el./cm2 with an energy of 6 MeV and an absorbed dose of 60Co gamma quanta of at least 700 krad. It is assumed that resistance of OAmp2, ADComp1, ADComp3 to the action of 60Co gamma quanta is significantly higher and requires further research. The developed analog components can be used in signal reading devices required in front-end of sensors for space instrumentation and nuclear electronics.https://doklady.bsuir.by/jour/article/view/3108operational amplifiercomparatormaster slice arrayradiation hardeness
collection DOAJ
language Russian
format Article
sources DOAJ
author O. V. Dvornikov
V. A. Tchekhovski
V. L. Dziatlau
Y. D. Galkin
Nikolay N. Prokopenko
spellingShingle O. V. Dvornikov
V. A. Tchekhovski
V. L. Dziatlau
Y. D. Galkin
Nikolay N. Prokopenko
Ionizing radiation influence on parameters of analog components of the master slice array МН2ХА030
Doklady Belorusskogo gosudarstvennogo universiteta informatiki i radioèlektroniki
operational amplifier
comparator
master slice array
radiation hardeness
author_facet O. V. Dvornikov
V. A. Tchekhovski
V. L. Dziatlau
Y. D. Galkin
Nikolay N. Prokopenko
author_sort O. V. Dvornikov
title Ionizing radiation influence on parameters of analog components of the master slice array МН2ХА030
title_short Ionizing radiation influence on parameters of analog components of the master slice array МН2ХА030
title_full Ionizing radiation influence on parameters of analog components of the master slice array МН2ХА030
title_fullStr Ionizing radiation influence on parameters of analog components of the master slice array МН2ХА030
title_full_unstemmed Ionizing radiation influence on parameters of analog components of the master slice array МН2ХА030
title_sort ionizing radiation influence on parameters of analog components of the master slice array мн2ха030
publisher Educational institution «Belarusian State University of Informatics and Radioelectronics»
series Doklady Belorusskogo gosudarstvennogo universiteta informatiki i radioèlektroniki
issn 1729-7648
publishDate 2021-07-01
description Structured arrays and master slice arrays are often used to reduce cost, design and test time for radiation hardened analog integrated circuits. One of such master slice arrays is МН2ХА030, which uses bipolar and junction field-effect transistors. The purpose of this article is to estimate the effect of ionizing radiation on the parameters of the operational amplifier OAmp2 and comparators ADComp1 and ADComp3 created on the МН2ХА030 master slice array. Еhe results of measurements of analog components after exposure to 60Co gamma quanta with an absorbed dose of up to 700 krad and a fast electron fluence of up to 2.9·1015 el./cm2 with an energy of 6 MeV are presented. The OAmp2 operational amplifier provides a satisfactory level of basic static parameters (input current, offset voltage, voltage gain) at a fast electron fluence of up to 3.7·1014 el./cm2 with an energy of 6 MeV. There are a decrease in the voltage gain and an increase in the offset voltage at electron fluence of greater than 1015 el./cm2. The latter can be caused by a decrease in the efficiency of the common-mode signal feedback integrated into operational amplifier with a significant drop in current gain of bipolar transistors. All considered analog components provide a satisfactory level of basic static parameters at a fast electron fluence of up to 3.7·1014 el./cm2 with an energy of 6 MeV and an absorbed dose of 60Co gamma quanta of at least 700 krad. It is assumed that resistance of OAmp2, ADComp1, ADComp3 to the action of 60Co gamma quanta is significantly higher and requires further research. The developed analog components can be used in signal reading devices required in front-end of sensors for space instrumentation and nuclear electronics.
topic operational amplifier
comparator
master slice array
radiation hardeness
url https://doklady.bsuir.by/jour/article/view/3108
work_keys_str_mv AT ovdvornikov ionizingradiationinfluenceonparametersofanalogcomponentsofthemasterslicearraymn2ha030
AT vatchekhovski ionizingradiationinfluenceonparametersofanalogcomponentsofthemasterslicearraymn2ha030
AT vldziatlau ionizingradiationinfluenceonparametersofanalogcomponentsofthemasterslicearraymn2ha030
AT ydgalkin ionizingradiationinfluenceonparametersofanalogcomponentsofthemasterslicearraymn2ha030
AT nikolaynprokopenko ionizingradiationinfluenceonparametersofanalogcomponentsofthemasterslicearraymn2ha030
_version_ 1721267590167265280