Influence of errors in an estimation of control parameters in an artificial kidney eqipment on the ef-fective value of hemodialysis index dose

<p><em> The possible reasons in a disagreement of scientists in an estimation of optimum value of haemodialysis index dose are analyzed. It is proved, that the modern mathematical models used for calculation the haemodialysis index dose, can decrease its real value by 20–30 % that can re...

Full description

Bibliographic Details
Main Authors: І.Ф. Бойко, С.Т. Поліщук
Format: Article
Language:English
Published: National Aviation University 2004-04-01
Series:Vìsnik Nacìonalʹnogo Avìacìjnogo Unìversitetu
Online Access:http://jrnl.nau.edu.ua/index.php/visnik/article/view/1074
id doaj-0ba44153bbe2440c87f05a606e7afcf4
record_format Article
spelling doaj-0ba44153bbe2440c87f05a606e7afcf42020-11-25T03:16:38ZengNational Aviation UniversityVìsnik Nacìonalʹnogo Avìacìjnogo Unìversitetu1813-11662306-14722004-04-01224374010.18372/2306-1472.22.10741049Influence of errors in an estimation of control parameters in an artificial kidney eqipment on the ef-fective value of hemodialysis index doseІ.Ф. Бойко0С.Т. Поліщук1Інститут електроніки та систем управління НАУІнститут електроніки та систем управління НАУ<p><em> The possible reasons in a disagreement of scientists in an estimation of optimum value of haemodialysis index dose are analyzed. It is proved, that the modern mathematical models used for calculation the haemodialysis index dose, can decrease its real value by 20–30 % that can result in ambiguity of compared results.</em></p>http://jrnl.nau.edu.ua/index.php/visnik/article/view/1074
collection DOAJ
language English
format Article
sources DOAJ
author І.Ф. Бойко
С.Т. Поліщук
spellingShingle І.Ф. Бойко
С.Т. Поліщук
Influence of errors in an estimation of control parameters in an artificial kidney eqipment on the ef-fective value of hemodialysis index dose
Vìsnik Nacìonalʹnogo Avìacìjnogo Unìversitetu
author_facet І.Ф. Бойко
С.Т. Поліщук
author_sort І.Ф. Бойко
title Influence of errors in an estimation of control parameters in an artificial kidney eqipment on the ef-fective value of hemodialysis index dose
title_short Influence of errors in an estimation of control parameters in an artificial kidney eqipment on the ef-fective value of hemodialysis index dose
title_full Influence of errors in an estimation of control parameters in an artificial kidney eqipment on the ef-fective value of hemodialysis index dose
title_fullStr Influence of errors in an estimation of control parameters in an artificial kidney eqipment on the ef-fective value of hemodialysis index dose
title_full_unstemmed Influence of errors in an estimation of control parameters in an artificial kidney eqipment on the ef-fective value of hemodialysis index dose
title_sort influence of errors in an estimation of control parameters in an artificial kidney eqipment on the ef-fective value of hemodialysis index dose
publisher National Aviation University
series Vìsnik Nacìonalʹnogo Avìacìjnogo Unìversitetu
issn 1813-1166
2306-1472
publishDate 2004-04-01
description <p><em> The possible reasons in a disagreement of scientists in an estimation of optimum value of haemodialysis index dose are analyzed. It is proved, that the modern mathematical models used for calculation the haemodialysis index dose, can decrease its real value by 20–30 % that can result in ambiguity of compared results.</em></p>