Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devices

Purpose: To compare the ocular anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, as measured with two different Scheimpflug imaging devices. Methods: This transversal study included 80 right eyes from 80 subjects aged from 20 to 40 years. Their spherical...

Full description

Bibliographic Details
Main Authors: Alberto Domínguez-Vicent, Daniel Monsálvez-Romín, Antonio Jesus Del Águila-Carrasco, Santiago García-Lázaro, Robert Montés-Micó
Format: Article
Language:English
Published: Conselho Brasileiro de Oftalmologia 2014-08-01
Series:Arquivos Brasileiros de Oftalmologia
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000400233&lng=en&tlng=en
id doaj-0ad19f65b83a43faa2cbdbe9f7b5f477
record_format Article
spelling doaj-0ad19f65b83a43faa2cbdbe9f7b5f4772020-11-24T21:09:07ZengConselho Brasileiro de OftalmologiaArquivos Brasileiros de Oftalmologia1678-29252014-08-0177423323710.5935/0004-2749.20140060S0004-27492014000400233Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devicesAlberto Domínguez-VicentDaniel Monsálvez-RomínAntonio Jesus Del Águila-CarrascoSantiago García-LázaroRobert Montés-MicóPurpose: To compare the ocular anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, as measured with two different Scheimpflug imaging devices. Methods: This transversal study included 80 right eyes from 80 subjects aged from 20 to 40 years. Their spherical equivalents ranged from -4.25 to +1.00 diopters (D). Each eye's anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, were measured for far vision using both the Galilei G4 (double Scheimpflug camera) and the Pentacam HR (single Scheimpflug camera) systems. Results: Mean anterior chamber depths were calculated as 3.12 ± 0.23 mm and 3.19 ± 0.24 mm when measured with the Galilei G4 and the Pentacam HR, respectively. The mean white-to-white distance measured was 11.84 ± 0.31 mm and 11.90 ± 0.43 mm when measured with the Galilei G4 and the Pentacam HR, respectively. Mean pupil diameters were measured as 3.22 ± 0.58 mm and 3.22 ± 0.52 mm when measured with the Galilei G4 and the Pentacam HR, respectively. Finally, the mean anterior chamber angle was 34.30 ± 2.86 degrees when it was measured with the Galilei G4, and 39.26 ± 2.85 degrees when measured with the Pentacam HR. A comparative analysis revealed that the Galilei G4 yielded a significantly lower (P<0.05) measurement for the anterior chamber depth, anterior chamber angle, and pupil diameter, than the Pentacam HR system. Comparable values (P>0.05) for both devices were obtained for the white-to-white distance measurements. Conclusion: The Galilei G4 and Pentacam HR Scheimpflug systems cannot be used interchangeably because they produce significant measurement differences.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000400233&lng=en&tlng=enCâmara anterior/patologiaPupila/fisiologiaTopografia da córneaTécnicas de diagnóstico oftalmológicoFotografia/métodosInterferometria
collection DOAJ
language English
format Article
sources DOAJ
author Alberto Domínguez-Vicent
Daniel Monsálvez-Romín
Antonio Jesus Del Águila-Carrasco
Santiago García-Lázaro
Robert Montés-Micó
spellingShingle Alberto Domínguez-Vicent
Daniel Monsálvez-Romín
Antonio Jesus Del Águila-Carrasco
Santiago García-Lázaro
Robert Montés-Micó
Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devices
Arquivos Brasileiros de Oftalmologia
Câmara anterior/patologia
Pupila/fisiologia
Topografia da córnea
Técnicas de diagnóstico oftalmológico
Fotografia/métodos
Interferometria
author_facet Alberto Domínguez-Vicent
Daniel Monsálvez-Romín
Antonio Jesus Del Águila-Carrasco
Santiago García-Lázaro
Robert Montés-Micó
author_sort Alberto Domínguez-Vicent
title Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devices
title_short Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devices
title_full Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devices
title_fullStr Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devices
title_full_unstemmed Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devices
title_sort measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two scheimpflug imaging devices
publisher Conselho Brasileiro de Oftalmologia
series Arquivos Brasileiros de Oftalmologia
issn 1678-2925
publishDate 2014-08-01
description Purpose: To compare the ocular anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, as measured with two different Scheimpflug imaging devices. Methods: This transversal study included 80 right eyes from 80 subjects aged from 20 to 40 years. Their spherical equivalents ranged from -4.25 to +1.00 diopters (D). Each eye's anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, were measured for far vision using both the Galilei G4 (double Scheimpflug camera) and the Pentacam HR (single Scheimpflug camera) systems. Results: Mean anterior chamber depths were calculated as 3.12 ± 0.23 mm and 3.19 ± 0.24 mm when measured with the Galilei G4 and the Pentacam HR, respectively. The mean white-to-white distance measured was 11.84 ± 0.31 mm and 11.90 ± 0.43 mm when measured with the Galilei G4 and the Pentacam HR, respectively. Mean pupil diameters were measured as 3.22 ± 0.58 mm and 3.22 ± 0.52 mm when measured with the Galilei G4 and the Pentacam HR, respectively. Finally, the mean anterior chamber angle was 34.30 ± 2.86 degrees when it was measured with the Galilei G4, and 39.26 ± 2.85 degrees when measured with the Pentacam HR. A comparative analysis revealed that the Galilei G4 yielded a significantly lower (P<0.05) measurement for the anterior chamber depth, anterior chamber angle, and pupil diameter, than the Pentacam HR system. Comparable values (P>0.05) for both devices were obtained for the white-to-white distance measurements. Conclusion: The Galilei G4 and Pentacam HR Scheimpflug systems cannot be used interchangeably because they produce significant measurement differences.
topic Câmara anterior/patologia
Pupila/fisiologia
Topografia da córnea
Técnicas de diagnóstico oftalmológico
Fotografia/métodos
Interferometria
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000400233&lng=en&tlng=en
work_keys_str_mv AT albertodominguezvicent measurementsofanteriorchamberdepthwhitetowhitedistanceanteriorchamberangleandpupildiameterusingtwoscheimpflugimagingdevices
AT danielmonsalvezromin measurementsofanteriorchamberdepthwhitetowhitedistanceanteriorchamberangleandpupildiameterusingtwoscheimpflugimagingdevices
AT antoniojesusdelaguilacarrasco measurementsofanteriorchamberdepthwhitetowhitedistanceanteriorchamberangleandpupildiameterusingtwoscheimpflugimagingdevices
AT santiagogarcialazaro measurementsofanteriorchamberdepthwhitetowhitedistanceanteriorchamberangleandpupildiameterusingtwoscheimpflugimagingdevices
AT robertmontesmico measurementsofanteriorchamberdepthwhitetowhitedistanceanteriorchamberangleandpupildiameterusingtwoscheimpflugimagingdevices
_version_ 1716758488378507264