Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devices
Purpose: To compare the ocular anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, as measured with two different Scheimpflug imaging devices. Methods: This transversal study included 80 right eyes from 80 subjects aged from 20 to 40 years. Their spherical...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Conselho Brasileiro de Oftalmologia
2014-08-01
|
Series: | Arquivos Brasileiros de Oftalmologia |
Subjects: | |
Online Access: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000400233&lng=en&tlng=en |
id |
doaj-0ad19f65b83a43faa2cbdbe9f7b5f477 |
---|---|
record_format |
Article |
spelling |
doaj-0ad19f65b83a43faa2cbdbe9f7b5f4772020-11-24T21:09:07ZengConselho Brasileiro de OftalmologiaArquivos Brasileiros de Oftalmologia1678-29252014-08-0177423323710.5935/0004-2749.20140060S0004-27492014000400233Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devicesAlberto Domínguez-VicentDaniel Monsálvez-RomínAntonio Jesus Del Águila-CarrascoSantiago García-LázaroRobert Montés-MicóPurpose: To compare the ocular anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, as measured with two different Scheimpflug imaging devices. Methods: This transversal study included 80 right eyes from 80 subjects aged from 20 to 40 years. Their spherical equivalents ranged from -4.25 to +1.00 diopters (D). Each eye's anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, were measured for far vision using both the Galilei G4 (double Scheimpflug camera) and the Pentacam HR (single Scheimpflug camera) systems. Results: Mean anterior chamber depths were calculated as 3.12 ± 0.23 mm and 3.19 ± 0.24 mm when measured with the Galilei G4 and the Pentacam HR, respectively. The mean white-to-white distance measured was 11.84 ± 0.31 mm and 11.90 ± 0.43 mm when measured with the Galilei G4 and the Pentacam HR, respectively. Mean pupil diameters were measured as 3.22 ± 0.58 mm and 3.22 ± 0.52 mm when measured with the Galilei G4 and the Pentacam HR, respectively. Finally, the mean anterior chamber angle was 34.30 ± 2.86 degrees when it was measured with the Galilei G4, and 39.26 ± 2.85 degrees when measured with the Pentacam HR. A comparative analysis revealed that the Galilei G4 yielded a significantly lower (P<0.05) measurement for the anterior chamber depth, anterior chamber angle, and pupil diameter, than the Pentacam HR system. Comparable values (P>0.05) for both devices were obtained for the white-to-white distance measurements. Conclusion: The Galilei G4 and Pentacam HR Scheimpflug systems cannot be used interchangeably because they produce significant measurement differences.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000400233&lng=en&tlng=enCâmara anterior/patologiaPupila/fisiologiaTopografia da córneaTécnicas de diagnóstico oftalmológicoFotografia/métodosInterferometria |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Alberto Domínguez-Vicent Daniel Monsálvez-Romín Antonio Jesus Del Águila-Carrasco Santiago García-Lázaro Robert Montés-Micó |
spellingShingle |
Alberto Domínguez-Vicent Daniel Monsálvez-Romín Antonio Jesus Del Águila-Carrasco Santiago García-Lázaro Robert Montés-Micó Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devices Arquivos Brasileiros de Oftalmologia Câmara anterior/patologia Pupila/fisiologia Topografia da córnea Técnicas de diagnóstico oftalmológico Fotografia/métodos Interferometria |
author_facet |
Alberto Domínguez-Vicent Daniel Monsálvez-Romín Antonio Jesus Del Águila-Carrasco Santiago García-Lázaro Robert Montés-Micó |
author_sort |
Alberto Domínguez-Vicent |
title |
Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devices |
title_short |
Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devices |
title_full |
Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devices |
title_fullStr |
Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devices |
title_full_unstemmed |
Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devices |
title_sort |
measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two scheimpflug imaging devices |
publisher |
Conselho Brasileiro de Oftalmologia |
series |
Arquivos Brasileiros de Oftalmologia |
issn |
1678-2925 |
publishDate |
2014-08-01 |
description |
Purpose: To compare the ocular anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, as measured with two different Scheimpflug imaging devices. Methods: This transversal study included 80 right eyes from 80 subjects aged from 20 to 40 years. Their spherical equivalents ranged from -4.25 to +1.00 diopters (D). Each eye's anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, were measured for far vision using both the Galilei G4 (double Scheimpflug camera) and the Pentacam HR (single Scheimpflug camera) systems. Results: Mean anterior chamber depths were calculated as 3.12 ± 0.23 mm and 3.19 ± 0.24 mm when measured with the Galilei G4 and the Pentacam HR, respectively. The mean white-to-white distance measured was 11.84 ± 0.31 mm and 11.90 ± 0.43 mm when measured with the Galilei G4 and the Pentacam HR, respectively. Mean pupil diameters were measured as 3.22 ± 0.58 mm and 3.22 ± 0.52 mm when measured with the Galilei G4 and the Pentacam HR, respectively. Finally, the mean anterior chamber angle was 34.30 ± 2.86 degrees when it was measured with the Galilei G4, and 39.26 ± 2.85 degrees when measured with the Pentacam HR. A comparative analysis revealed that the Galilei G4 yielded a significantly lower (P<0.05) measurement for the anterior chamber depth, anterior chamber angle, and pupil diameter, than the Pentacam HR system. Comparable values (P>0.05) for both devices were obtained for the white-to-white distance measurements. Conclusion: The Galilei G4 and Pentacam HR Scheimpflug systems cannot be used interchangeably because they produce significant measurement differences. |
topic |
Câmara anterior/patologia Pupila/fisiologia Topografia da córnea Técnicas de diagnóstico oftalmológico Fotografia/métodos Interferometria |
url |
http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000400233&lng=en&tlng=en |
work_keys_str_mv |
AT albertodominguezvicent measurementsofanteriorchamberdepthwhitetowhitedistanceanteriorchamberangleandpupildiameterusingtwoscheimpflugimagingdevices AT danielmonsalvezromin measurementsofanteriorchamberdepthwhitetowhitedistanceanteriorchamberangleandpupildiameterusingtwoscheimpflugimagingdevices AT antoniojesusdelaguilacarrasco measurementsofanteriorchamberdepthwhitetowhitedistanceanteriorchamberangleandpupildiameterusingtwoscheimpflugimagingdevices AT santiagogarcialazaro measurementsofanteriorchamberdepthwhitetowhitedistanceanteriorchamberangleandpupildiameterusingtwoscheimpflugimagingdevices AT robertmontesmico measurementsofanteriorchamberdepthwhitetowhitedistanceanteriorchamberangleandpupildiameterusingtwoscheimpflugimagingdevices |
_version_ |
1716758488378507264 |