Mid-term Outcomes of Using Custom-Made Implants for Revision Hip Arthroplasty
Introduction. The matter of the replacement of acetabular defects is becoming increasingly relevant today. In their clinic the authors used custom-made implants with trabecular coating for replacement of defects in the acetabulum where and when it was necessary to ensure extended fixation of the com...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | Russian |
Published: |
Vreden Russian Research Institute of Traumatology and Orthopedics
2019-10-01
|
Series: | Travmatologiâ i Ortopediâ Rossii |
Subjects: | |
Online Access: | https://journal.rniito.org/jour/article/view/1295 |
id |
doaj-0aca46ac833040d184b5a649d1cf0ecf |
---|---|
record_format |
Article |
spelling |
doaj-0aca46ac833040d184b5a649d1cf0ecf2021-07-29T08:01:20ZrusVreden Russian Research Institute of Traumatology and OrthopedicsTravmatologiâ i Ortopediâ Rossii2311-29052542-09332019-10-01253374610.21823/2311-2905-2019-25-3-37-46810Mid-term Outcomes of Using Custom-Made Implants for Revision Hip ArthroplastyA. N. Kovalenko0A. A. Dzhavadov1I. I. Shubnyakov2S. S. Bilyk3A. O. Denisov4M. A. Cherkasov5A. I. Midaev6R. M. Tikhilov7Vreden Russian Research Institute of Traumatology and OrthopedicsVreden Russian Research Institute of Traumatology and OrthopedicsVreden Russian Research Institute of Traumatology and OrthopedicsVreden Russian Research Institute of Traumatology and OrthopedicsVreden Russian Research Institute of Traumatology and OrthopedicsVreden Russian Research Institute of Traumatology and OrthopedicsVreden Russian Research Institute of Traumatology and OrthopedicsVreden Russian Research Institute of Traumatology and Orthopedics, Mechnikov North-Western State Medical UniversityIntroduction. The matter of the replacement of acetabular defects is becoming increasingly relevant today. In their clinic the authors used custom-made implants with trabecular coating for replacement of defects in the acetabulum where and when it was necessary to ensure extended fixation of the component. Purpose — to evaluate short-term clinical and functional outcomes, osteointegration of porous coated custom-made implants, the overall survival of structural components and to identify the causes of failures and complications. Materials and Methods. During the study the authors interviewed and evaluated radiographs of 48 patients operated from October 2015 to June 2018. The patients were interviewed before and after the surgery using the Oxford hip joint scale, quality of life EQ-5D and visual analogue pain scale. Radiographs were evaluated for a period of at least 12 months for the signs of osteointegration. Results. The average OHS scores increased from 14.9 (±7) to 37.6 (±7) (p<0.01). Quality of life according to the EQ-5D index increased from 0.2 (±0.2) to 0.7 (±0.2) (p<0.01). The average value by general health scales: before operations — 49 (±17) and 73 (±18) scores after surgeries (p<0.01). The average VAS pain score decreased from 73 (±10) to 19 (±19) points (p<0.01). Osteointegration was observed in 98 percent of cases. Migration of the implant with fracture of a flange was observed in one case. Conclusions. In the short-term follow up the use of custom-made implants significantly improves hip joint function and the patients’ life quality. Custom-made implants enable primary reliable fixation in case of complex acetabular defects. High rate of osteointegration is observed for custom-made implants with porous coating within at least 12 months. Longer follow-up is needed to evaluate long-term results.https://journal.rniito.org/jour/article/view/1295custom-made implantship revision arthroplasty |
collection |
DOAJ |
language |
Russian |
format |
Article |
sources |
DOAJ |
author |
A. N. Kovalenko A. A. Dzhavadov I. I. Shubnyakov S. S. Bilyk A. O. Denisov M. A. Cherkasov A. I. Midaev R. M. Tikhilov |
spellingShingle |
A. N. Kovalenko A. A. Dzhavadov I. I. Shubnyakov S. S. Bilyk A. O. Denisov M. A. Cherkasov A. I. Midaev R. M. Tikhilov Mid-term Outcomes of Using Custom-Made Implants for Revision Hip Arthroplasty Travmatologiâ i Ortopediâ Rossii custom-made implants hip revision arthroplasty |
author_facet |
A. N. Kovalenko A. A. Dzhavadov I. I. Shubnyakov S. S. Bilyk A. O. Denisov M. A. Cherkasov A. I. Midaev R. M. Tikhilov |
author_sort |
A. N. Kovalenko |
title |
Mid-term Outcomes of Using Custom-Made Implants for Revision Hip Arthroplasty |
title_short |
Mid-term Outcomes of Using Custom-Made Implants for Revision Hip Arthroplasty |
title_full |
Mid-term Outcomes of Using Custom-Made Implants for Revision Hip Arthroplasty |
title_fullStr |
Mid-term Outcomes of Using Custom-Made Implants for Revision Hip Arthroplasty |
title_full_unstemmed |
Mid-term Outcomes of Using Custom-Made Implants for Revision Hip Arthroplasty |
title_sort |
mid-term outcomes of using custom-made implants for revision hip arthroplasty |
publisher |
Vreden Russian Research Institute of Traumatology and Orthopedics |
series |
Travmatologiâ i Ortopediâ Rossii |
issn |
2311-2905 2542-0933 |
publishDate |
2019-10-01 |
description |
Introduction. The matter of the replacement of acetabular defects is becoming increasingly relevant today. In their clinic the authors used custom-made implants with trabecular coating for replacement of defects in the acetabulum where and when it was necessary to ensure extended fixation of the component. Purpose — to evaluate short-term clinical and functional outcomes, osteointegration of porous coated custom-made implants, the overall survival of structural components and to identify the causes of failures and complications. Materials and Methods. During the study the authors interviewed and evaluated radiographs of 48 patients operated from October 2015 to June 2018. The patients were interviewed before and after the surgery using the Oxford hip joint scale, quality of life EQ-5D and visual analogue pain scale. Radiographs were evaluated for a period of at least 12 months for the signs of osteointegration. Results. The average OHS scores increased from 14.9 (±7) to 37.6 (±7) (p<0.01). Quality of life according to the EQ-5D index increased from 0.2 (±0.2) to 0.7 (±0.2) (p<0.01). The average value by general health scales: before operations — 49 (±17) and 73 (±18) scores after surgeries (p<0.01). The average VAS pain score decreased from 73 (±10) to 19 (±19) points (p<0.01). Osteointegration was observed in 98 percent of cases. Migration of the implant with fracture of a flange was observed in one case. Conclusions. In the short-term follow up the use of custom-made implants significantly improves hip joint function and the patients’ life quality. Custom-made implants enable primary reliable fixation in case of complex acetabular defects. High rate of osteointegration is observed for custom-made implants with porous coating within at least 12 months. Longer follow-up is needed to evaluate long-term results. |
topic |
custom-made implants hip revision arthroplasty |
url |
https://journal.rniito.org/jour/article/view/1295 |
work_keys_str_mv |
AT ankovalenko midtermoutcomesofusingcustommadeimplantsforrevisionhiparthroplasty AT aadzhavadov midtermoutcomesofusingcustommadeimplantsforrevisionhiparthroplasty AT iishubnyakov midtermoutcomesofusingcustommadeimplantsforrevisionhiparthroplasty AT ssbilyk midtermoutcomesofusingcustommadeimplantsforrevisionhiparthroplasty AT aodenisov midtermoutcomesofusingcustommadeimplantsforrevisionhiparthroplasty AT macherkasov midtermoutcomesofusingcustommadeimplantsforrevisionhiparthroplasty AT aimidaev midtermoutcomesofusingcustommadeimplantsforrevisionhiparthroplasty AT rmtikhilov midtermoutcomesofusingcustommadeimplantsforrevisionhiparthroplasty |
_version_ |
1721258799338094592 |