Mid-term Outcomes of Using Custom-Made Implants for Revision Hip Arthroplasty

Introduction. The matter of the replacement of acetabular defects is becoming increasingly relevant today. In their clinic the authors used custom-made implants with trabecular coating for replacement of defects in the acetabulum where and when it was necessary to ensure extended fixation of the com...

Full description

Bibliographic Details
Main Authors: A. N. Kovalenko, A. A. Dzhavadov, I. I. Shubnyakov, S. S. Bilyk, A. O. Denisov, M. A. Cherkasov, A. I. Midaev, R. M. Tikhilov
Format: Article
Language:Russian
Published: Vreden Russian Research Institute of Traumatology and Orthopedics 2019-10-01
Series:Travmatologiâ i Ortopediâ Rossii
Subjects:
Online Access:https://journal.rniito.org/jour/article/view/1295
id doaj-0aca46ac833040d184b5a649d1cf0ecf
record_format Article
spelling doaj-0aca46ac833040d184b5a649d1cf0ecf2021-07-29T08:01:20ZrusVreden Russian Research Institute of Traumatology and OrthopedicsTravmatologiâ i Ortopediâ Rossii2311-29052542-09332019-10-01253374610.21823/2311-2905-2019-25-3-37-46810Mid-term Outcomes of Using Custom-Made Implants for Revision Hip ArthroplastyA. N. Kovalenko0A. A. Dzhavadov1I. I. Shubnyakov2S. S. Bilyk3A. O. Denisov4M. A. Cherkasov5A. I. Midaev6R. M. Tikhilov7Vreden Russian Research Institute of Traumatology and OrthopedicsVreden Russian Research Institute of Traumatology and OrthopedicsVreden Russian Research Institute of Traumatology and OrthopedicsVreden Russian Research Institute of Traumatology and OrthopedicsVreden Russian Research Institute of Traumatology and OrthopedicsVreden Russian Research Institute of Traumatology and OrthopedicsVreden Russian Research Institute of Traumatology and OrthopedicsVreden Russian Research Institute of Traumatology and Orthopedics, Mechnikov North-Western State Medical UniversityIntroduction. The matter of the replacement of acetabular defects is becoming increasingly relevant today. In their clinic the authors used custom-made implants with trabecular coating for replacement of defects in the acetabulum where and when it was necessary to ensure extended fixation of the component. Purpose — to evaluate short-term clinical and functional outcomes, osteointegration of porous coated custom-made implants, the overall survival of structural components and to identify the causes of failures and complications. Materials and Methods. During the study the authors interviewed and evaluated radiographs of 48 patients operated from October 2015 to June 2018. The patients were interviewed before and after the surgery using the Oxford hip joint scale, quality of life EQ-5D and visual analogue pain scale. Radiographs were evaluated for a period of at least 12 months for the signs of osteointegration. Results. The average OHS scores increased from 14.9 (±7) to 37.6 (±7) (p<0.01). Quality of life according to the EQ-5D index increased from 0.2 (±0.2) to 0.7 (±0.2) (p<0.01). The average value by general health scales: before operations — 49 (±17) and 73 (±18) scores after surgeries (p<0.01). The average VAS pain score decreased from 73 (±10) to 19 (±19) points (p<0.01). Osteointegration was observed in 98 percent of cases. Migration of the implant with fracture of a flange was observed in one case. Conclusions. In the short-term follow up the use of custom-made implants significantly improves hip joint function and the patients’ life quality. Custom-made implants enable primary reliable fixation in case of complex acetabular defects. High rate of osteointegration is observed for custom-made implants with porous coating within at least 12 months. Longer follow-up is needed to evaluate long-term results.https://journal.rniito.org/jour/article/view/1295custom-made implantship revision arthroplasty
collection DOAJ
language Russian
format Article
sources DOAJ
author A. N. Kovalenko
A. A. Dzhavadov
I. I. Shubnyakov
S. S. Bilyk
A. O. Denisov
M. A. Cherkasov
A. I. Midaev
R. M. Tikhilov
spellingShingle A. N. Kovalenko
A. A. Dzhavadov
I. I. Shubnyakov
S. S. Bilyk
A. O. Denisov
M. A. Cherkasov
A. I. Midaev
R. M. Tikhilov
Mid-term Outcomes of Using Custom-Made Implants for Revision Hip Arthroplasty
Travmatologiâ i Ortopediâ Rossii
custom-made implants
hip revision arthroplasty
author_facet A. N. Kovalenko
A. A. Dzhavadov
I. I. Shubnyakov
S. S. Bilyk
A. O. Denisov
M. A. Cherkasov
A. I. Midaev
R. M. Tikhilov
author_sort A. N. Kovalenko
title Mid-term Outcomes of Using Custom-Made Implants for Revision Hip Arthroplasty
title_short Mid-term Outcomes of Using Custom-Made Implants for Revision Hip Arthroplasty
title_full Mid-term Outcomes of Using Custom-Made Implants for Revision Hip Arthroplasty
title_fullStr Mid-term Outcomes of Using Custom-Made Implants for Revision Hip Arthroplasty
title_full_unstemmed Mid-term Outcomes of Using Custom-Made Implants for Revision Hip Arthroplasty
title_sort mid-term outcomes of using custom-made implants for revision hip arthroplasty
publisher Vreden Russian Research Institute of Traumatology and Orthopedics
series Travmatologiâ i Ortopediâ Rossii
issn 2311-2905
2542-0933
publishDate 2019-10-01
description Introduction. The matter of the replacement of acetabular defects is becoming increasingly relevant today. In their clinic the authors used custom-made implants with trabecular coating for replacement of defects in the acetabulum where and when it was necessary to ensure extended fixation of the component. Purpose — to evaluate short-term clinical and functional outcomes, osteointegration of porous coated custom-made implants, the overall survival of structural components and to identify the causes of failures and complications. Materials and Methods. During the study the authors interviewed and evaluated radiographs of 48 patients operated from October 2015 to June 2018. The patients were interviewed before and after the surgery using the Oxford hip joint scale, quality of life EQ-5D and visual analogue pain scale. Radiographs were evaluated for a period of at least 12 months for the signs of osteointegration. Results. The average OHS scores increased from 14.9 (±7) to 37.6 (±7) (p<0.01). Quality of life according to the EQ-5D index increased from 0.2 (±0.2) to 0.7 (±0.2) (p<0.01). The average value by general health scales: before operations — 49 (±17) and 73 (±18) scores after surgeries (p<0.01). The average VAS pain score decreased from 73 (±10) to 19 (±19) points (p<0.01). Osteointegration was observed in 98 percent of cases. Migration of the implant with fracture of a flange was observed in one case. Conclusions. In the short-term follow up the use of custom-made implants significantly improves hip joint function and the patients’ life quality. Custom-made implants enable primary reliable fixation in case of complex acetabular defects. High rate of osteointegration is observed for custom-made implants with porous coating within at least 12 months. Longer follow-up is needed to evaluate long-term results.
topic custom-made implants
hip revision arthroplasty
url https://journal.rniito.org/jour/article/view/1295
work_keys_str_mv AT ankovalenko midtermoutcomesofusingcustommadeimplantsforrevisionhiparthroplasty
AT aadzhavadov midtermoutcomesofusingcustommadeimplantsforrevisionhiparthroplasty
AT iishubnyakov midtermoutcomesofusingcustommadeimplantsforrevisionhiparthroplasty
AT ssbilyk midtermoutcomesofusingcustommadeimplantsforrevisionhiparthroplasty
AT aodenisov midtermoutcomesofusingcustommadeimplantsforrevisionhiparthroplasty
AT macherkasov midtermoutcomesofusingcustommadeimplantsforrevisionhiparthroplasty
AT aimidaev midtermoutcomesofusingcustommadeimplantsforrevisionhiparthroplasty
AT rmtikhilov midtermoutcomesofusingcustommadeimplantsforrevisionhiparthroplasty
_version_ 1721258799338094592