Shape memory polymer ovarian vein embolisation in a patient with nickel allergy

Abstract Background Ovarian vein embolization in pelvic varicocele is usually obtained using nitinol coils. These devices can not be used in patients with proven nickel allergy. Case presentation Shape memory polymer is a new embolic material available to interventionalists. A patient presented with...

Full description

Bibliographic Details
Main Authors: Davide Castellano, Andrea Boghi, Luca Di Maggio, Alessandro Rapellino, Daniele Savio
Format: Article
Language:English
Published: SpringerOpen 2021-03-01
Series:CVIR Endovascular
Subjects:
Online Access:https://doi.org/10.1186/s42155-021-00212-y
id doaj-0a9ee93466d5446c93737ef027760b9e
record_format Article
spelling doaj-0a9ee93466d5446c93737ef027760b9e2021-03-11T12:46:04ZengSpringerOpenCVIR Endovascular2520-89342021-03-01411410.1186/s42155-021-00212-yShape memory polymer ovarian vein embolisation in a patient with nickel allergyDavide Castellano0Andrea Boghi1Luca Di Maggio2Alessandro Rapellino3Daniele Savio4Department of Interventional Radiology and Neuroradiology, San Giovanni Bosco HospitalDepartment of Interventional Radiology and Neuroradiology, San Giovanni Bosco HospitalDepartment of Interventional Radiology and Neuroradiology, San Giovanni Bosco HospitalDepartment of Interventional Radiology and Neuroradiology, San Giovanni Bosco HospitalDepartment of Interventional Radiology and Neuroradiology, San Giovanni Bosco HospitalAbstract Background Ovarian vein embolization in pelvic varicocele is usually obtained using nitinol coils. These devices can not be used in patients with proven nickel allergy. Case presentation Shape memory polymer is a new embolic material available to interventionalists. A patient presented with pelvic congestion syndrome requiring embolisation of the left ovarian vein. The target vessel consisted of two twisted branches, each 5–6 mm in diameter. The patient also had a known allergy to nickel. Considering the anatomy and allergy status, embolisation with polyurethane shape memory polymer vascular plugs was considered a good case strategy. The embolisation procedure was technically successful with the deployment of two shape memory polymer plugs into each of the two left ovarian vein branches. Follow-up magnetic resonance imaging at 4 months showed sustained occlusion of the treated vessels and the patient showed no signs of allergy to the implanted material. Conclusions In conclusion, our case presented an opportunity to utilise a new embolic material and achieve a good outcome in a patient with an allergy that may have resulted in complications when using metallic implants.https://doi.org/10.1186/s42155-021-00212-yShape memory polymerVascular plugPeripheral embolisationPelvic congestion syndromeNickel allergy
collection DOAJ
language English
format Article
sources DOAJ
author Davide Castellano
Andrea Boghi
Luca Di Maggio
Alessandro Rapellino
Daniele Savio
spellingShingle Davide Castellano
Andrea Boghi
Luca Di Maggio
Alessandro Rapellino
Daniele Savio
Shape memory polymer ovarian vein embolisation in a patient with nickel allergy
CVIR Endovascular
Shape memory polymer
Vascular plug
Peripheral embolisation
Pelvic congestion syndrome
Nickel allergy
author_facet Davide Castellano
Andrea Boghi
Luca Di Maggio
Alessandro Rapellino
Daniele Savio
author_sort Davide Castellano
title Shape memory polymer ovarian vein embolisation in a patient with nickel allergy
title_short Shape memory polymer ovarian vein embolisation in a patient with nickel allergy
title_full Shape memory polymer ovarian vein embolisation in a patient with nickel allergy
title_fullStr Shape memory polymer ovarian vein embolisation in a patient with nickel allergy
title_full_unstemmed Shape memory polymer ovarian vein embolisation in a patient with nickel allergy
title_sort shape memory polymer ovarian vein embolisation in a patient with nickel allergy
publisher SpringerOpen
series CVIR Endovascular
issn 2520-8934
publishDate 2021-03-01
description Abstract Background Ovarian vein embolization in pelvic varicocele is usually obtained using nitinol coils. These devices can not be used in patients with proven nickel allergy. Case presentation Shape memory polymer is a new embolic material available to interventionalists. A patient presented with pelvic congestion syndrome requiring embolisation of the left ovarian vein. The target vessel consisted of two twisted branches, each 5–6 mm in diameter. The patient also had a known allergy to nickel. Considering the anatomy and allergy status, embolisation with polyurethane shape memory polymer vascular plugs was considered a good case strategy. The embolisation procedure was technically successful with the deployment of two shape memory polymer plugs into each of the two left ovarian vein branches. Follow-up magnetic resonance imaging at 4 months showed sustained occlusion of the treated vessels and the patient showed no signs of allergy to the implanted material. Conclusions In conclusion, our case presented an opportunity to utilise a new embolic material and achieve a good outcome in a patient with an allergy that may have resulted in complications when using metallic implants.
topic Shape memory polymer
Vascular plug
Peripheral embolisation
Pelvic congestion syndrome
Nickel allergy
url https://doi.org/10.1186/s42155-021-00212-y
work_keys_str_mv AT davidecastellano shapememorypolymerovarianveinembolisationinapatientwithnickelallergy
AT andreaboghi shapememorypolymerovarianveinembolisationinapatientwithnickelallergy
AT lucadimaggio shapememorypolymerovarianveinembolisationinapatientwithnickelallergy
AT alessandrorapellino shapememorypolymerovarianveinembolisationinapatientwithnickelallergy
AT danielesavio shapememorypolymerovarianveinembolisationinapatientwithnickelallergy
_version_ 1724223996648488960