Clinical observation of micro-coaxial phacoemulsification for axial high myopia with cataract
AIM: To observe the clinical effect of micro-coaxial phacoemulsification combined with intraocular lens implantation in axial high myopia with cataract.<p>METHODS: Fifty-three patients(74 eyes)with axial high myopia and cataract underwent micro-coaxial phacoemulsification combined with intraoc...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Press of International Journal of Ophthalmology (IJO PRESS)
2014-11-01
|
Series: | Guoji Yanke Zazhi |
Subjects: | |
Online Access: | http://www.ies.net.cn/cn_publish/2014/11/201411043.pdf |
id |
doaj-0a83dd54b9794878b20c1de8c0c41467 |
---|---|
record_format |
Article |
spelling |
doaj-0a83dd54b9794878b20c1de8c0c414672020-11-24T21:13:56ZengPress of International Journal of Ophthalmology (IJO PRESS)Guoji Yanke Zazhi1672-51231672-51232014-11-0114112066206810.3980/j.issn.1672-5123.2014.11.43Clinical observation of micro-coaxial phacoemulsification for axial high myopia with cataractRui-Fan Zhang0Shao-Wei Yang1Zheng-Zheng Wu2Department of Ophthalmology, Sichuan Provincial People's Hospital, Chengdu 610072, Sichuan Province, ChinaDepartment of Ophthalmology, Sichuan Provincial People's Hospital, Chengdu 610072, Sichuan Province, ChinaDepartment of Ophthalmology, Sichuan Provincial People's Hospital, Chengdu 610072, Sichuan Province, ChinaAIM: To observe the clinical effect of micro-coaxial phacoemulsification combined with intraocular lens implantation in axial high myopia with cataract.<p>METHODS: Fifty-three patients(74 eyes)with axial high myopia and cataract underwent micro-coaxial phacoemulsification combined with intraocular lens implantation between April 2013 and December 2013. The best corrected visual acuity(BCVA)was observed at 1 and 3mo after operation, and the complications were recorded.<p>RESULTS: Compared with the preoperative, BCVA was improved at 1 and 3mo after operation, and the differences were statistically significant(<i>P</i><0.05). There was no statistically significant difference between 1 and 3mo after operation(<i>P</i>>0.05). There was no incidence of complications, such as retinal detachment, iris damage, pupil deformation, cystoid macular edema, endophthalmitis after operation in all patients.<p>CONCLUSION:Micro-coaxial phacoemulsification combined with intraocular lens implantation is an effective and safe method for axial high myopia with cataract.http://www.ies.net.cn/cn_publish/2014/11/201411043.pdfcataractmicroincisionphacoemulsificationhigh myopia |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Rui-Fan Zhang Shao-Wei Yang Zheng-Zheng Wu |
spellingShingle |
Rui-Fan Zhang Shao-Wei Yang Zheng-Zheng Wu Clinical observation of micro-coaxial phacoemulsification for axial high myopia with cataract Guoji Yanke Zazhi cataract microincision phacoemulsification high myopia |
author_facet |
Rui-Fan Zhang Shao-Wei Yang Zheng-Zheng Wu |
author_sort |
Rui-Fan Zhang |
title |
Clinical observation of micro-coaxial phacoemulsification for axial high myopia with cataract |
title_short |
Clinical observation of micro-coaxial phacoemulsification for axial high myopia with cataract |
title_full |
Clinical observation of micro-coaxial phacoemulsification for axial high myopia with cataract |
title_fullStr |
Clinical observation of micro-coaxial phacoemulsification for axial high myopia with cataract |
title_full_unstemmed |
Clinical observation of micro-coaxial phacoemulsification for axial high myopia with cataract |
title_sort |
clinical observation of micro-coaxial phacoemulsification for axial high myopia with cataract |
publisher |
Press of International Journal of Ophthalmology (IJO PRESS) |
series |
Guoji Yanke Zazhi |
issn |
1672-5123 1672-5123 |
publishDate |
2014-11-01 |
description |
AIM: To observe the clinical effect of micro-coaxial phacoemulsification combined with intraocular lens implantation in axial high myopia with cataract.<p>METHODS: Fifty-three patients(74 eyes)with axial high myopia and cataract underwent micro-coaxial phacoemulsification combined with intraocular lens implantation between April 2013 and December 2013. The best corrected visual acuity(BCVA)was observed at 1 and 3mo after operation, and the complications were recorded.<p>RESULTS: Compared with the preoperative, BCVA was improved at 1 and 3mo after operation, and the differences were statistically significant(<i>P</i><0.05). There was no statistically significant difference between 1 and 3mo after operation(<i>P</i>>0.05). There was no incidence of complications, such as retinal detachment, iris damage, pupil deformation, cystoid macular edema, endophthalmitis after operation in all patients.<p>CONCLUSION:Micro-coaxial phacoemulsification combined with intraocular lens implantation is an effective and safe method for axial high myopia with cataract. |
topic |
cataract microincision phacoemulsification high myopia |
url |
http://www.ies.net.cn/cn_publish/2014/11/201411043.pdf |
work_keys_str_mv |
AT ruifanzhang clinicalobservationofmicrocoaxialphacoemulsificationforaxialhighmyopiawithcataract AT shaoweiyang clinicalobservationofmicrocoaxialphacoemulsificationforaxialhighmyopiawithcataract AT zhengzhengwu clinicalobservationofmicrocoaxialphacoemulsificationforaxialhighmyopiawithcataract |
_version_ |
1716747832748146688 |