Experimental Assessment on the Flexural Bonding Performance of Concrete Beam with GFRP Reinforcing Bar under Repeated Loading

This study intends to investigate the flexural bond performance of glass fiber-reinforced polymer (GFRP) reinforcing bar under repeated loading. The flexural bond tests reinforced with GFRP reinforcing bars were carried out according to the BS EN 12269-1 (2000) specification. The bond test consisted...

Full description

Bibliographic Details
Main Authors: Minkwan Ju, Hongseob Oh
Format: Article
Language:English
Published: Hindawi Limited 2015-01-01
Series:International Journal of Polymer Science
Online Access:http://dx.doi.org/10.1155/2015/367528
id doaj-0a836ea262d14cc9a753c0e098e834f9
record_format Article
spelling doaj-0a836ea262d14cc9a753c0e098e834f92020-11-25T00:02:05ZengHindawi LimitedInternational Journal of Polymer Science1687-94221687-94302015-01-01201510.1155/2015/367528367528Experimental Assessment on the Flexural Bonding Performance of Concrete Beam with GFRP Reinforcing Bar under Repeated LoadingMinkwan Ju0Hongseob Oh1Department of Civil Engineering, Kangwon National University, 1 Joongang-ro, Samcheok-si, Gangwon 245-711, Republic of KoreaDepartment of Civil Engineering, Gyeongnam National University of Science and Technology, 150 Chilam-dong, Jinju, Gyeongnam 660-758, Republic of KoreaThis study intends to investigate the flexural bond performance of glass fiber-reinforced polymer (GFRP) reinforcing bar under repeated loading. The flexural bond tests reinforced with GFRP reinforcing bars were carried out according to the BS EN 12269-1 (2000) specification. The bond test consisted of three loading schemes: static, monotonic, and variable-amplitude loading to simulate ambient loading conditions. The empirical bond length based on the static test was 225 mm, whereas it was 317 mm according to ACI 440 1R-03. Each bond stress on the rib is released and bonding force is enhanced as the bond length is increased. Appropriate level of bond length may be recommended with this energy-based analysis. For the monotonic loading test, the bond strengths at pullout failure after 2,000,000 cycles were 10.4 MPa and 6.5 MPa, respectively: 63–70% of the values from the static loading test. The variable loading test indicated that the linear cumulative damage theory on GFRP bonding may not be appropriate for estimating the fatigue limit when subjected to variable-amplitude loading.http://dx.doi.org/10.1155/2015/367528
collection DOAJ
language English
format Article
sources DOAJ
author Minkwan Ju
Hongseob Oh
spellingShingle Minkwan Ju
Hongseob Oh
Experimental Assessment on the Flexural Bonding Performance of Concrete Beam with GFRP Reinforcing Bar under Repeated Loading
International Journal of Polymer Science
author_facet Minkwan Ju
Hongseob Oh
author_sort Minkwan Ju
title Experimental Assessment on the Flexural Bonding Performance of Concrete Beam with GFRP Reinforcing Bar under Repeated Loading
title_short Experimental Assessment on the Flexural Bonding Performance of Concrete Beam with GFRP Reinforcing Bar under Repeated Loading
title_full Experimental Assessment on the Flexural Bonding Performance of Concrete Beam with GFRP Reinforcing Bar under Repeated Loading
title_fullStr Experimental Assessment on the Flexural Bonding Performance of Concrete Beam with GFRP Reinforcing Bar under Repeated Loading
title_full_unstemmed Experimental Assessment on the Flexural Bonding Performance of Concrete Beam with GFRP Reinforcing Bar under Repeated Loading
title_sort experimental assessment on the flexural bonding performance of concrete beam with gfrp reinforcing bar under repeated loading
publisher Hindawi Limited
series International Journal of Polymer Science
issn 1687-9422
1687-9430
publishDate 2015-01-01
description This study intends to investigate the flexural bond performance of glass fiber-reinforced polymer (GFRP) reinforcing bar under repeated loading. The flexural bond tests reinforced with GFRP reinforcing bars were carried out according to the BS EN 12269-1 (2000) specification. The bond test consisted of three loading schemes: static, monotonic, and variable-amplitude loading to simulate ambient loading conditions. The empirical bond length based on the static test was 225 mm, whereas it was 317 mm according to ACI 440 1R-03. Each bond stress on the rib is released and bonding force is enhanced as the bond length is increased. Appropriate level of bond length may be recommended with this energy-based analysis. For the monotonic loading test, the bond strengths at pullout failure after 2,000,000 cycles were 10.4 MPa and 6.5 MPa, respectively: 63–70% of the values from the static loading test. The variable loading test indicated that the linear cumulative damage theory on GFRP bonding may not be appropriate for estimating the fatigue limit when subjected to variable-amplitude loading.
url http://dx.doi.org/10.1155/2015/367528
work_keys_str_mv AT minkwanju experimentalassessmentontheflexuralbondingperformanceofconcretebeamwithgfrpreinforcingbarunderrepeatedloading
AT hongseoboh experimentalassessmentontheflexuralbondingperformanceofconcretebeamwithgfrpreinforcingbarunderrepeatedloading
_version_ 1725439660737429504