Spatial–Temporal Analysis of the Heat and Electricity Demand of the Swiss Building Stock

In 2015, space heating and domestic hot water production accounted for around 40% of the Swiss final energy consumption. Reaching the goals of the 2050 energy strategy will require significantly reducing this share despite the growing building stock. Renewables are numerous but subject to spatial–te...

Full description

Bibliographic Details
Main Authors: Stefan Schneider, Pierre Hollmuller, Pascale Le Strat, Jad Khoury, Martin Patel, Bernard Lachal
Format: Article
Language:English
Published: Frontiers Media S.A. 2017-08-01
Series:Frontiers in Built Environment
Subjects:
Online Access:http://journal.frontiersin.org/article/10.3389/fbuil.2017.00053/full
id doaj-0a28bbe056f74f419584ed8447813439
record_format Article
spelling doaj-0a28bbe056f74f419584ed84478134392020-11-24T21:08:38ZengFrontiers Media S.A.Frontiers in Built Environment2297-33622017-08-01310.3389/fbuil.2017.00053284351Spatial–Temporal Analysis of the Heat and Electricity Demand of the Swiss Building StockStefan Schneider0Pierre Hollmuller1Pascale Le Strat2Jad Khoury3Martin Patel4Bernard Lachal5Energy System Group, Institute for Environmental Sciences (ISE), Department F.-A. Forel for Environmental and Aquatic Sciences (DEFSE), University of Geneva, Geneva, SwitzerlandEnergy System Group, Institute for Environmental Sciences (ISE), Department F.-A. Forel for Environmental and Aquatic Sciences (DEFSE), University of Geneva, Geneva, SwitzerlandServices industriels de Genève, Le Lignon, SwitzerlandEnergy System Group, Institute for Environmental Sciences (ISE), Department F.-A. Forel for Environmental and Aquatic Sciences (DEFSE), University of Geneva, Geneva, SwitzerlandFaculty of Science, Department F.-A. Forel for Environmental and Aquatic Sciences (DEFSE), Institute for Environmental Sciences (ISE), University of Geneva, Geneva, SwitzerlandEnergy System Group, Institute for Environmental Sciences (ISE), Department F.-A. Forel for Environmental and Aquatic Sciences (DEFSE), University of Geneva, Geneva, SwitzerlandIn 2015, space heating and domestic hot water production accounted for around 40% of the Swiss final energy consumption. Reaching the goals of the 2050 energy strategy will require significantly reducing this share despite the growing building stock. Renewables are numerous but subject to spatial–temporal constraints. Territorial planning of energy distribution systems enabling the integration of renewables requires having a spatial–temporal characterization of the energy demand. This paper presents two bottom-up statistical extrapolation models for the estimation of the geo-dependent heat and electricity demand of the Swiss building stock. The heat demand is estimated by means of a statistical bottom-up model applied at the building level. At the municipality level, the electricity load curve is estimated by combining socio-economic indicators with average consumption per activity and/or electric device. This approach also allows to break down the estimated electricity demand according to activity type (e.g., households, various industry, and service activities) and appliance type (e.g., lighting, motor force, fridges). The total estimated aggregated demand is 94 TWh for heat and 58 TWh for electricity, which represent a deviation of 2.9 and 0.5%, respectively compared to the national energy consumption statistics. In addition, comparisons between estimated and measured electric load curves are done to validate the proposed approach. Finally, these models are used to build a geo-referred database of heat and electricity demand for the entire Swiss territory. As an application of the heat demand model, a realistic saving potential is estimated for the existing building stock; this potential could be achieved through by a deep retrofit program. One advantage of the statistical bottom-up model approach is that it allows to simulate a building stock that replicates the diversity of building demand. This point is important in order to correctly account for the mismatch between gross and net energy saving potential, often called performance gap. The impact of this performance gap is substantial since the estimated net saving potential is only half of the gross one.http://journal.frontiersin.org/article/10.3389/fbuil.2017.00053/fullgeo-depended energy demandenergy consumption by usebuilding classificationelectric load curvebottom-up model
collection DOAJ
language English
format Article
sources DOAJ
author Stefan Schneider
Pierre Hollmuller
Pascale Le Strat
Jad Khoury
Martin Patel
Bernard Lachal
spellingShingle Stefan Schneider
Pierre Hollmuller
Pascale Le Strat
Jad Khoury
Martin Patel
Bernard Lachal
Spatial–Temporal Analysis of the Heat and Electricity Demand of the Swiss Building Stock
Frontiers in Built Environment
geo-depended energy demand
energy consumption by use
building classification
electric load curve
bottom-up model
author_facet Stefan Schneider
Pierre Hollmuller
Pascale Le Strat
Jad Khoury
Martin Patel
Bernard Lachal
author_sort Stefan Schneider
title Spatial–Temporal Analysis of the Heat and Electricity Demand of the Swiss Building Stock
title_short Spatial–Temporal Analysis of the Heat and Electricity Demand of the Swiss Building Stock
title_full Spatial–Temporal Analysis of the Heat and Electricity Demand of the Swiss Building Stock
title_fullStr Spatial–Temporal Analysis of the Heat and Electricity Demand of the Swiss Building Stock
title_full_unstemmed Spatial–Temporal Analysis of the Heat and Electricity Demand of the Swiss Building Stock
title_sort spatial–temporal analysis of the heat and electricity demand of the swiss building stock
publisher Frontiers Media S.A.
series Frontiers in Built Environment
issn 2297-3362
publishDate 2017-08-01
description In 2015, space heating and domestic hot water production accounted for around 40% of the Swiss final energy consumption. Reaching the goals of the 2050 energy strategy will require significantly reducing this share despite the growing building stock. Renewables are numerous but subject to spatial–temporal constraints. Territorial planning of energy distribution systems enabling the integration of renewables requires having a spatial–temporal characterization of the energy demand. This paper presents two bottom-up statistical extrapolation models for the estimation of the geo-dependent heat and electricity demand of the Swiss building stock. The heat demand is estimated by means of a statistical bottom-up model applied at the building level. At the municipality level, the electricity load curve is estimated by combining socio-economic indicators with average consumption per activity and/or electric device. This approach also allows to break down the estimated electricity demand according to activity type (e.g., households, various industry, and service activities) and appliance type (e.g., lighting, motor force, fridges). The total estimated aggregated demand is 94 TWh for heat and 58 TWh for electricity, which represent a deviation of 2.9 and 0.5%, respectively compared to the national energy consumption statistics. In addition, comparisons between estimated and measured electric load curves are done to validate the proposed approach. Finally, these models are used to build a geo-referred database of heat and electricity demand for the entire Swiss territory. As an application of the heat demand model, a realistic saving potential is estimated for the existing building stock; this potential could be achieved through by a deep retrofit program. One advantage of the statistical bottom-up model approach is that it allows to simulate a building stock that replicates the diversity of building demand. This point is important in order to correctly account for the mismatch between gross and net energy saving potential, often called performance gap. The impact of this performance gap is substantial since the estimated net saving potential is only half of the gross one.
topic geo-depended energy demand
energy consumption by use
building classification
electric load curve
bottom-up model
url http://journal.frontiersin.org/article/10.3389/fbuil.2017.00053/full
work_keys_str_mv AT stefanschneider spatialtemporalanalysisoftheheatandelectricitydemandoftheswissbuildingstock
AT pierrehollmuller spatialtemporalanalysisoftheheatandelectricitydemandoftheswissbuildingstock
AT pascalelestrat spatialtemporalanalysisoftheheatandelectricitydemandoftheswissbuildingstock
AT jadkhoury spatialtemporalanalysisoftheheatandelectricitydemandoftheswissbuildingstock
AT martinpatel spatialtemporalanalysisoftheheatandelectricitydemandoftheswissbuildingstock
AT bernardlachal spatialtemporalanalysisoftheheatandelectricitydemandoftheswissbuildingstock
_version_ 1716760084498874368