Estimating raindrop size distributions using microwave link measurements: potential and limitations

<p>We present a novel method of using two or three collocated microwave link instruments to estimate the three parameters of a gamma raindrop size distribution (DSD) model. This allows path-average DSD measurements over a path length of several kilometers as opposed to the point measurements o...

Full description

Bibliographic Details
Main Authors: T. C. van Leth, H. Leijnse, A. Overeem, R. Uijlenhoet
Format: Article
Language:English
Published: Copernicus Publications 2020-04-01
Series:Atmospheric Measurement Techniques
Online Access:https://www.atmos-meas-tech.net/13/1797/2020/amt-13-1797-2020.pdf
id doaj-0a0f25db63934de091d36df08074dd86
record_format Article
spelling doaj-0a0f25db63934de091d36df08074dd862020-11-25T02:26:36ZengCopernicus PublicationsAtmospheric Measurement Techniques1867-13811867-85482020-04-01131797181510.5194/amt-13-1797-2020Estimating raindrop size distributions using microwave link measurements: potential and limitationsT. C. van Leth0H. Leijnse1A. Overeem2A. Overeem3R. Uijlenhoet4Hydrology and Quantitative Water Management Group, Wageningen University, Wageningen, the NetherlandsR&D Observations and Data Technology, Royal Netherlands Meteorological Institute (KNMI), De Bilt, the NetherlandsHydrology and Quantitative Water Management Group, Wageningen University, Wageningen, the NetherlandsR&D Observations and Data Technology, Royal Netherlands Meteorological Institute (KNMI), De Bilt, the NetherlandsHydrology and Quantitative Water Management Group, Wageningen University, Wageningen, the Netherlands<p>We present a novel method of using two or three collocated microwave link instruments to estimate the three parameters of a gamma raindrop size distribution (DSD) model. This allows path-average DSD measurements over a path length of several kilometers as opposed to the point measurements of conventional disdrometers. Our method is validated in a round-trip manner using simulated DSD fields as well as five laser disdrometers installed along a path. Different potential link combinations of frequency and polarization are investigated. We also present preliminary results from the application of this method to an experimental setup of collocated microwave links measuring at 26 and 38&thinsp;<span class="inline-formula">GHz</span> along a 2.2&thinsp;<span class="inline-formula">km</span> path. Simulations show that a DSD retrieval on the basis of microwave links can be accurate under idealized conditions. We found that a triple-link retrieval provides little added benefit over a dual-link retrieval in terms of accuracy or precision. In practice, the accuracy and success rate of any retrieval is highly dependent on the stability of the base power level as well as the precision of the instruments and in particular the quantization applied to the recorded power level.</p>https://www.atmos-meas-tech.net/13/1797/2020/amt-13-1797-2020.pdf
collection DOAJ
language English
format Article
sources DOAJ
author T. C. van Leth
H. Leijnse
A. Overeem
A. Overeem
R. Uijlenhoet
spellingShingle T. C. van Leth
H. Leijnse
A. Overeem
A. Overeem
R. Uijlenhoet
Estimating raindrop size distributions using microwave link measurements: potential and limitations
Atmospheric Measurement Techniques
author_facet T. C. van Leth
H. Leijnse
A. Overeem
A. Overeem
R. Uijlenhoet
author_sort T. C. van Leth
title Estimating raindrop size distributions using microwave link measurements: potential and limitations
title_short Estimating raindrop size distributions using microwave link measurements: potential and limitations
title_full Estimating raindrop size distributions using microwave link measurements: potential and limitations
title_fullStr Estimating raindrop size distributions using microwave link measurements: potential and limitations
title_full_unstemmed Estimating raindrop size distributions using microwave link measurements: potential and limitations
title_sort estimating raindrop size distributions using microwave link measurements: potential and limitations
publisher Copernicus Publications
series Atmospheric Measurement Techniques
issn 1867-1381
1867-8548
publishDate 2020-04-01
description <p>We present a novel method of using two or three collocated microwave link instruments to estimate the three parameters of a gamma raindrop size distribution (DSD) model. This allows path-average DSD measurements over a path length of several kilometers as opposed to the point measurements of conventional disdrometers. Our method is validated in a round-trip manner using simulated DSD fields as well as five laser disdrometers installed along a path. Different potential link combinations of frequency and polarization are investigated. We also present preliminary results from the application of this method to an experimental setup of collocated microwave links measuring at 26 and 38&thinsp;<span class="inline-formula">GHz</span> along a 2.2&thinsp;<span class="inline-formula">km</span> path. Simulations show that a DSD retrieval on the basis of microwave links can be accurate under idealized conditions. We found that a triple-link retrieval provides little added benefit over a dual-link retrieval in terms of accuracy or precision. In practice, the accuracy and success rate of any retrieval is highly dependent on the stability of the base power level as well as the precision of the instruments and in particular the quantization applied to the recorded power level.</p>
url https://www.atmos-meas-tech.net/13/1797/2020/amt-13-1797-2020.pdf
work_keys_str_mv AT tcvanleth estimatingraindropsizedistributionsusingmicrowavelinkmeasurementspotentialandlimitations
AT hleijnse estimatingraindropsizedistributionsusingmicrowavelinkmeasurementspotentialandlimitations
AT aovereem estimatingraindropsizedistributionsusingmicrowavelinkmeasurementspotentialandlimitations
AT aovereem estimatingraindropsizedistributionsusingmicrowavelinkmeasurementspotentialandlimitations
AT ruijlenhoet estimatingraindropsizedistributionsusingmicrowavelinkmeasurementspotentialandlimitations
_version_ 1724846029215367168