Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol

Multidetector computed tomography (MDCT) scanning has enabled the early diagnosis of hyperacute brain ischemia. We aimed at validating a standardized protocol to read and report MDCT techniques in a series of adult patients. The inter-observer agreement among the trained examiners was tested, and th...

Full description

Bibliographic Details
Main Authors: Felipe Torres Pacheco, Antonio Jose da Rocha, Ingrid Aguiar Littig, Antonio Carlos Martins Maia Junior, Rubens Jose Gagliardi
Format: Article
Language:English
Published: Academia Brasileira de Neurologia (ABNEURO) 2013-06-01
Series:Arquivos de Neuro-Psiquiatria
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2013000600349&lng=en&tlng=en
id doaj-09dc9f6916694a59950537e15079018d
record_format Article
spelling doaj-09dc9f6916694a59950537e15079018d2020-11-24T23:06:26ZengAcademia Brasileira de Neurologia (ABNEURO)Arquivos de Neuro-Psiquiatria1678-42272013-06-0171634935610.1590/0004-282X20130037S0004-282X2013000600349Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocolFelipe Torres PachecoAntonio Jose da RochaIngrid Aguiar LittigAntonio Carlos Martins Maia JuniorRubens Jose GagliardiMultidetector computed tomography (MDCT) scanning has enabled the early diagnosis of hyperacute brain ischemia. We aimed at validating a standardized protocol to read and report MDCT techniques in a series of adult patients. The inter-observer agreement among the trained examiners was tested, and their results were compared with a standard reading. No false positives were observed, and an almost perfect agreement (Kappa>0.81) was documented when the CT angiography (CTA) and cerebral perfusion CT (CPCT) map data were added to the noncontrast CT (NCCT) analysis. The inter-observer agreement was higher for highly trained readers, corroborating the need for specific training to interpret these modern techniques. The authors recommend adding CTA and CPCT to the NCCT analysis in order to clarify the global analysis of structural and hemodynamic brain abnormalities. Our structured report is suitable as a script for the reproducible analysis of the MDCT of patients on suspicion of ischemic stroke.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2013000600349&lng=en&tlng=entomographyperfusionangiographystrokecerebral infarctiontomografiaperfusaoangiografiaacidente vascular cerebralinfarto cerebral
collection DOAJ
language English
format Article
sources DOAJ
author Felipe Torres Pacheco
Antonio Jose da Rocha
Ingrid Aguiar Littig
Antonio Carlos Martins Maia Junior
Rubens Jose Gagliardi
spellingShingle Felipe Torres Pacheco
Antonio Jose da Rocha
Ingrid Aguiar Littig
Antonio Carlos Martins Maia Junior
Rubens Jose Gagliardi
Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol
Arquivos de Neuro-Psiquiatria
tomography
perfusion
angiography
stroke
cerebral infarction
tomografia
perfusao
angiografia
acidente vascular cerebral
infarto cerebral
author_facet Felipe Torres Pacheco
Antonio Jose da Rocha
Ingrid Aguiar Littig
Antonio Carlos Martins Maia Junior
Rubens Jose Gagliardi
author_sort Felipe Torres Pacheco
title Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol
title_short Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol
title_full Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol
title_fullStr Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol
title_full_unstemmed Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol
title_sort multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol
publisher Academia Brasileira de Neurologia (ABNEURO)
series Arquivos de Neuro-Psiquiatria
issn 1678-4227
publishDate 2013-06-01
description Multidetector computed tomography (MDCT) scanning has enabled the early diagnosis of hyperacute brain ischemia. We aimed at validating a standardized protocol to read and report MDCT techniques in a series of adult patients. The inter-observer agreement among the trained examiners was tested, and their results were compared with a standard reading. No false positives were observed, and an almost perfect agreement (Kappa>0.81) was documented when the CT angiography (CTA) and cerebral perfusion CT (CPCT) map data were added to the noncontrast CT (NCCT) analysis. The inter-observer agreement was higher for highly trained readers, corroborating the need for specific training to interpret these modern techniques. The authors recommend adding CTA and CPCT to the NCCT analysis in order to clarify the global analysis of structural and hemodynamic brain abnormalities. Our structured report is suitable as a script for the reproducible analysis of the MDCT of patients on suspicion of ischemic stroke.
topic tomography
perfusion
angiography
stroke
cerebral infarction
tomografia
perfusao
angiografia
acidente vascular cerebral
infarto cerebral
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2013000600349&lng=en&tlng=en
work_keys_str_mv AT felipetorrespacheco multiparametricmultidetectorcomputedtomographyscanningonsuspicionofhyperacuteischemicstrokevalidatingastandardizedprotocol
AT antoniojosedarocha multiparametricmultidetectorcomputedtomographyscanningonsuspicionofhyperacuteischemicstrokevalidatingastandardizedprotocol
AT ingridaguiarlittig multiparametricmultidetectorcomputedtomographyscanningonsuspicionofhyperacuteischemicstrokevalidatingastandardizedprotocol
AT antoniocarlosmartinsmaiajunior multiparametricmultidetectorcomputedtomographyscanningonsuspicionofhyperacuteischemicstrokevalidatingastandardizedprotocol
AT rubensjosegagliardi multiparametricmultidetectorcomputedtomographyscanningonsuspicionofhyperacuteischemicstrokevalidatingastandardizedprotocol
_version_ 1725623026187239424