Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol
Multidetector computed tomography (MDCT) scanning has enabled the early diagnosis of hyperacute brain ischemia. We aimed at validating a standardized protocol to read and report MDCT techniques in a series of adult patients. The inter-observer agreement among the trained examiners was tested, and th...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Academia Brasileira de Neurologia (ABNEURO)
2013-06-01
|
Series: | Arquivos de Neuro-Psiquiatria |
Subjects: | |
Online Access: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2013000600349&lng=en&tlng=en |
id |
doaj-09dc9f6916694a59950537e15079018d |
---|---|
record_format |
Article |
spelling |
doaj-09dc9f6916694a59950537e15079018d2020-11-24T23:06:26ZengAcademia Brasileira de Neurologia (ABNEURO)Arquivos de Neuro-Psiquiatria1678-42272013-06-0171634935610.1590/0004-282X20130037S0004-282X2013000600349Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocolFelipe Torres PachecoAntonio Jose da RochaIngrid Aguiar LittigAntonio Carlos Martins Maia JuniorRubens Jose GagliardiMultidetector computed tomography (MDCT) scanning has enabled the early diagnosis of hyperacute brain ischemia. We aimed at validating a standardized protocol to read and report MDCT techniques in a series of adult patients. The inter-observer agreement among the trained examiners was tested, and their results were compared with a standard reading. No false positives were observed, and an almost perfect agreement (Kappa>0.81) was documented when the CT angiography (CTA) and cerebral perfusion CT (CPCT) map data were added to the noncontrast CT (NCCT) analysis. The inter-observer agreement was higher for highly trained readers, corroborating the need for specific training to interpret these modern techniques. The authors recommend adding CTA and CPCT to the NCCT analysis in order to clarify the global analysis of structural and hemodynamic brain abnormalities. Our structured report is suitable as a script for the reproducible analysis of the MDCT of patients on suspicion of ischemic stroke.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2013000600349&lng=en&tlng=entomographyperfusionangiographystrokecerebral infarctiontomografiaperfusaoangiografiaacidente vascular cerebralinfarto cerebral |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Felipe Torres Pacheco Antonio Jose da Rocha Ingrid Aguiar Littig Antonio Carlos Martins Maia Junior Rubens Jose Gagliardi |
spellingShingle |
Felipe Torres Pacheco Antonio Jose da Rocha Ingrid Aguiar Littig Antonio Carlos Martins Maia Junior Rubens Jose Gagliardi Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol Arquivos de Neuro-Psiquiatria tomography perfusion angiography stroke cerebral infarction tomografia perfusao angiografia acidente vascular cerebral infarto cerebral |
author_facet |
Felipe Torres Pacheco Antonio Jose da Rocha Ingrid Aguiar Littig Antonio Carlos Martins Maia Junior Rubens Jose Gagliardi |
author_sort |
Felipe Torres Pacheco |
title |
Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol |
title_short |
Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol |
title_full |
Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol |
title_fullStr |
Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol |
title_full_unstemmed |
Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol |
title_sort |
multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol |
publisher |
Academia Brasileira de Neurologia (ABNEURO) |
series |
Arquivos de Neuro-Psiquiatria |
issn |
1678-4227 |
publishDate |
2013-06-01 |
description |
Multidetector computed tomography (MDCT) scanning has enabled the early diagnosis of hyperacute brain ischemia. We aimed at validating a standardized protocol to read and report MDCT techniques in a series of adult patients. The inter-observer agreement among the trained examiners was tested, and their results were compared with a standard reading. No false positives were observed, and an almost perfect agreement (Kappa>0.81) was documented when the CT angiography (CTA) and cerebral perfusion CT (CPCT) map data were added to the noncontrast CT (NCCT) analysis. The inter-observer agreement was higher for highly trained readers, corroborating the need for specific training to interpret these modern techniques. The authors recommend adding CTA and CPCT to the NCCT analysis in order to clarify the global analysis of structural and hemodynamic brain abnormalities. Our structured report is suitable as a script for the reproducible analysis of the MDCT of patients on suspicion of ischemic stroke. |
topic |
tomography perfusion angiography stroke cerebral infarction tomografia perfusao angiografia acidente vascular cerebral infarto cerebral |
url |
http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2013000600349&lng=en&tlng=en |
work_keys_str_mv |
AT felipetorrespacheco multiparametricmultidetectorcomputedtomographyscanningonsuspicionofhyperacuteischemicstrokevalidatingastandardizedprotocol AT antoniojosedarocha multiparametricmultidetectorcomputedtomographyscanningonsuspicionofhyperacuteischemicstrokevalidatingastandardizedprotocol AT ingridaguiarlittig multiparametricmultidetectorcomputedtomographyscanningonsuspicionofhyperacuteischemicstrokevalidatingastandardizedprotocol AT antoniocarlosmartinsmaiajunior multiparametricmultidetectorcomputedtomographyscanningonsuspicionofhyperacuteischemicstrokevalidatingastandardizedprotocol AT rubensjosegagliardi multiparametricmultidetectorcomputedtomographyscanningonsuspicionofhyperacuteischemicstrokevalidatingastandardizedprotocol |
_version_ |
1725623026187239424 |