Uncemented, curved, short endoprosthesis stem for distal femoral reconstruction: early follow-up outcomes
Abstract Background Uncemented endoprosthetic knee replacement has become a mainstream treatment for malignant tumours of the distal femur. Most femoral stems, however, are straight and therefore poorly fit the anteriorly bowed curvature of the femur. To address this issue, we used a short, curved,...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
BMC
2018-09-01
|
Series: | World Journal of Surgical Oncology |
Subjects: | |
Online Access: | http://link.springer.com/article/10.1186/s12957-018-1486-3 |
id |
doaj-09b2ff43dc704bf2b73448492985eb53 |
---|---|
record_format |
Article |
spelling |
doaj-09b2ff43dc704bf2b73448492985eb532020-11-25T02:13:26ZengBMCWorld Journal of Surgical Oncology1477-78192018-09-0116111110.1186/s12957-018-1486-3Uncemented, curved, short endoprosthesis stem for distal femoral reconstruction: early follow-up outcomesMinxun Lu0Jie Wang1Cong Xiao2Fan Tang3Li Min4Yong Zhou5Wenli Zhang6Chongqi Tu7Department of Orthopedics, West China Hospital, Sichuan UniversityDepartment of Orthopedics, West China Hospital, Sichuan UniversityDepartment of Orthopedics, West China Hospital, Sichuan UniversityDepartment of Orthopedics, West China Hospital, Sichuan UniversityDepartment of Orthopedics, West China Hospital, Sichuan UniversityDepartment of Orthopedics, West China Hospital, Sichuan UniversityDepartment of Orthopedics, West China Hospital, Sichuan UniversityDepartment of Orthopedics, West China Hospital, Sichuan UniversityAbstract Background Uncemented endoprosthetic knee replacement has become a mainstream treatment for malignant tumours of the distal femur. Most femoral stems, however, are straight and therefore poorly fit the anteriorly bowed curvature of the femur. To address this issue, we used a short, curved, uncemented press-fit femoral stem and evaluated its short-term outcomes after reconstruction of the distal femur. Methods Forty-two patients underwent distal femur replacement using curved press-fit stem. To assess the interface, we measured the axial length of the press-fit area and the perpendicular distance of the radiolucent area between the stem and bone on digital images obtained using tomosynthesis with Shimadzu Metal Artefact Reduction Technology (T-SMART). Postoperative complications and oncological outcomes were monitored at each follow-up visit. Results Of the 42 patients enrolled in the study, two had cancer-related deaths and one had local tumour recurrence. The minimum follow-up time of the surviving patients was 24 months, with no incidence of aseptic loosening or mechanical failure of the prosthesis. The average effective contact length between the press-fit stem and bone was 74.0 mm, with nearly undetectable radiolucent gaps between the implant and the bone on medial-lateral and anteroposterior views. Conclusions Over the short term, uncemented, curved, short stem provides a stable bone-prosthesis interface without any aseptic loosening.http://link.springer.com/article/10.1186/s12957-018-1486-3UncementedCurvatureDistal femurStemShort |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Minxun Lu Jie Wang Cong Xiao Fan Tang Li Min Yong Zhou Wenli Zhang Chongqi Tu |
spellingShingle |
Minxun Lu Jie Wang Cong Xiao Fan Tang Li Min Yong Zhou Wenli Zhang Chongqi Tu Uncemented, curved, short endoprosthesis stem for distal femoral reconstruction: early follow-up outcomes World Journal of Surgical Oncology Uncemented Curvature Distal femur Stem Short |
author_facet |
Minxun Lu Jie Wang Cong Xiao Fan Tang Li Min Yong Zhou Wenli Zhang Chongqi Tu |
author_sort |
Minxun Lu |
title |
Uncemented, curved, short endoprosthesis stem for distal femoral reconstruction: early follow-up outcomes |
title_short |
Uncemented, curved, short endoprosthesis stem for distal femoral reconstruction: early follow-up outcomes |
title_full |
Uncemented, curved, short endoprosthesis stem for distal femoral reconstruction: early follow-up outcomes |
title_fullStr |
Uncemented, curved, short endoprosthesis stem for distal femoral reconstruction: early follow-up outcomes |
title_full_unstemmed |
Uncemented, curved, short endoprosthesis stem for distal femoral reconstruction: early follow-up outcomes |
title_sort |
uncemented, curved, short endoprosthesis stem for distal femoral reconstruction: early follow-up outcomes |
publisher |
BMC |
series |
World Journal of Surgical Oncology |
issn |
1477-7819 |
publishDate |
2018-09-01 |
description |
Abstract Background Uncemented endoprosthetic knee replacement has become a mainstream treatment for malignant tumours of the distal femur. Most femoral stems, however, are straight and therefore poorly fit the anteriorly bowed curvature of the femur. To address this issue, we used a short, curved, uncemented press-fit femoral stem and evaluated its short-term outcomes after reconstruction of the distal femur. Methods Forty-two patients underwent distal femur replacement using curved press-fit stem. To assess the interface, we measured the axial length of the press-fit area and the perpendicular distance of the radiolucent area between the stem and bone on digital images obtained using tomosynthesis with Shimadzu Metal Artefact Reduction Technology (T-SMART). Postoperative complications and oncological outcomes were monitored at each follow-up visit. Results Of the 42 patients enrolled in the study, two had cancer-related deaths and one had local tumour recurrence. The minimum follow-up time of the surviving patients was 24 months, with no incidence of aseptic loosening or mechanical failure of the prosthesis. The average effective contact length between the press-fit stem and bone was 74.0 mm, with nearly undetectable radiolucent gaps between the implant and the bone on medial-lateral and anteroposterior views. Conclusions Over the short term, uncemented, curved, short stem provides a stable bone-prosthesis interface without any aseptic loosening. |
topic |
Uncemented Curvature Distal femur Stem Short |
url |
http://link.springer.com/article/10.1186/s12957-018-1486-3 |
work_keys_str_mv |
AT minxunlu uncementedcurvedshortendoprosthesisstemfordistalfemoralreconstructionearlyfollowupoutcomes AT jiewang uncementedcurvedshortendoprosthesisstemfordistalfemoralreconstructionearlyfollowupoutcomes AT congxiao uncementedcurvedshortendoprosthesisstemfordistalfemoralreconstructionearlyfollowupoutcomes AT fantang uncementedcurvedshortendoprosthesisstemfordistalfemoralreconstructionearlyfollowupoutcomes AT limin uncementedcurvedshortendoprosthesisstemfordistalfemoralreconstructionearlyfollowupoutcomes AT yongzhou uncementedcurvedshortendoprosthesisstemfordistalfemoralreconstructionearlyfollowupoutcomes AT wenlizhang uncementedcurvedshortendoprosthesisstemfordistalfemoralreconstructionearlyfollowupoutcomes AT chongqitu uncementedcurvedshortendoprosthesisstemfordistalfemoralreconstructionearlyfollowupoutcomes |
_version_ |
1724905307651440640 |