Improving voltage profile of load bus of wind generation system using DSTATCOM
In a low voltage distribution system with integrated wind plant, voltage stability is impacted by the large variation of load and wind penetration. The compensators like SVC and DSTATCOM are currently being used to address such issue of voltage instability. This paper analyses the impact of wind pen...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
University of Cape Town
2017-04-01
|
Series: | Journal of Energy in Southern Africa |
Online Access: | https://journals.assaf.org.za/jesa/article/view/2114 |
id |
doaj-0964dd4e07924e4f9f61e7388de1f098 |
---|---|
record_format |
Article |
spelling |
doaj-0964dd4e07924e4f9f61e7388de1f0982020-11-25T00:08:05ZengUniversity of Cape TownJournal of Energy in Southern Africa1021-447X2413-30512017-04-01264818710.17159/2413-3051/2015/v26i4a21142114Improving voltage profile of load bus of wind generation system using DSTATCOMManju Aggarwal0Madhusudan SinghS.K. GuptaUniversity of Cape TownIn a low voltage distribution system with integrated wind plant, voltage stability is impacted by the large variation of load and wind penetration. The compensators like SVC and DSTATCOM are currently being used to address such issue of voltage instability. This paper analyses the impact of wind penetration and variation of active and reactive power of the load on voltage profile of a wind generation system with and without DSTATCOM. It also analyses the performance of the system during fault by calculating various parameters of the system. It has been demonstrated that voltage stability margin increases using DSTATCOM at different wind penetration levels. This system has been simulated and analysed in MATLAB 2011b using a power system toolbox under steady state and transient conditions.https://journals.assaf.org.za/jesa/article/view/2114 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Manju Aggarwal Madhusudan Singh S.K. Gupta |
spellingShingle |
Manju Aggarwal Madhusudan Singh S.K. Gupta Improving voltage profile of load bus of wind generation system using DSTATCOM Journal of Energy in Southern Africa |
author_facet |
Manju Aggarwal Madhusudan Singh S.K. Gupta |
author_sort |
Manju Aggarwal |
title |
Improving voltage profile of load bus of wind generation system using DSTATCOM |
title_short |
Improving voltage profile of load bus of wind generation system using DSTATCOM |
title_full |
Improving voltage profile of load bus of wind generation system using DSTATCOM |
title_fullStr |
Improving voltage profile of load bus of wind generation system using DSTATCOM |
title_full_unstemmed |
Improving voltage profile of load bus of wind generation system using DSTATCOM |
title_sort |
improving voltage profile of load bus of wind generation system using dstatcom |
publisher |
University of Cape Town |
series |
Journal of Energy in Southern Africa |
issn |
1021-447X 2413-3051 |
publishDate |
2017-04-01 |
description |
In a low voltage distribution system with integrated wind plant, voltage stability is impacted by the large variation of load and wind penetration. The compensators like SVC and DSTATCOM are currently being used to address such issue of voltage instability. This paper analyses the impact of wind penetration and variation of active and reactive power of the load on voltage profile of a wind generation system with and without DSTATCOM. It also analyses the performance of the system during fault by calculating various parameters of the system. It has been demonstrated that voltage stability margin increases using DSTATCOM at different wind penetration levels. This system has been simulated and analysed in MATLAB 2011b using a power system toolbox under steady state and transient conditions. |
url |
https://journals.assaf.org.za/jesa/article/view/2114 |
work_keys_str_mv |
AT manjuaggarwal improvingvoltageprofileofloadbusofwindgenerationsystemusingdstatcom AT madhusudansingh improvingvoltageprofileofloadbusofwindgenerationsystemusingdstatcom AT skgupta improvingvoltageprofileofloadbusofwindgenerationsystemusingdstatcom |
_version_ |
1725416834462646272 |