Detection of Antibodies against Hydatid Cyst Fluid Antigens Using Immunoblot Technique
Introduction: Immunoblot is recognized as a sensitive and specific serological method for diagnosis of human hydatidosis. To analyze the reactivity of hydatid patients sera with the subunits of 2 major hydatid cyst fluid antigens, ( 5 and B ) immunoblot method was used. Material & Methods:In thi...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | fas |
Published: |
Shahid Sadoughi University of Medical Sciences
2004-07-01
|
Series: | Majallah-i Dānishgāh-i ’Ulūm-i Pizishkī-i Shahīd Ṣadūqī Yazd |
Subjects: | |
Online Access: | http://jssu.ssu.ac.ir/browse.php?a_id=1231&slc_lang=en&sid=1&ftxt=1 |
id |
doaj-0957ce13fee840809f7ffd065f2b5179 |
---|---|
record_format |
Article |
spelling |
doaj-0957ce13fee840809f7ffd065f2b51792020-11-25T02:20:13ZfasShahid Sadoughi University of Medical SciencesMajallah-i Dānishgāh-i ’Ulūm-i Pizishkī-i Shahīd Ṣadūqī Yazd2228-57412228-57332004-07-011223338Detection of Antibodies against Hydatid Cyst Fluid Antigens Using Immunoblot TechniqueF JalosianA Zavvaran HosseiniA Dalimi AslF Ghaffari-FarIntroduction: Immunoblot is recognized as a sensitive and specific serological method for diagnosis of human hydatidosis. To analyze the reactivity of hydatid patients sera with the subunits of 2 major hydatid cyst fluid antigens, ( 5 and B ) immunoblot method was used. Material & Methods:In this regard, 100 sera ,of which 40 sera from patients with surgically diagnosed hydatidosis, 20 sera from patients with parasitic disease other than hydatidosis, 20 sera from patients other than parasitic disease, and 20 sera from healthy controls were examined. Results: For 3 subunits of Ag B (12, 16, 20 kD) the sensitivities were 92.5%, 84.5% and 87.5% respectively and their specificity for all of the 3 subunits was 100%. For 2 subunits of Ag 5, (55, 65 kD) the sensitivity was 100% and the specificities were 100% and 90% respectively . Conclusion: The results indicated that the best subunit for hydatidosis diagnosis is the 55 kD subunit of Ag 5. Meanwhile, a lower reactivity (84.5% of all hydatid sera) was observed with 16 kD subunits of Ag B. http://jssu.ssu.ac.ir/browse.php?a_id=1231&slc_lang=en&sid=1&ftxt=1HydatidosisImmunoblotSerology |
collection |
DOAJ |
language |
fas |
format |
Article |
sources |
DOAJ |
author |
F Jalosian A Zavvaran Hosseini A Dalimi Asl F Ghaffari-Far |
spellingShingle |
F Jalosian A Zavvaran Hosseini A Dalimi Asl F Ghaffari-Far Detection of Antibodies against Hydatid Cyst Fluid Antigens Using Immunoblot Technique Majallah-i Dānishgāh-i ’Ulūm-i Pizishkī-i Shahīd Ṣadūqī Yazd Hydatidosis Immunoblot Serology |
author_facet |
F Jalosian A Zavvaran Hosseini A Dalimi Asl F Ghaffari-Far |
author_sort |
F Jalosian |
title |
Detection of Antibodies against Hydatid Cyst Fluid Antigens Using Immunoblot Technique |
title_short |
Detection of Antibodies against Hydatid Cyst Fluid Antigens Using Immunoblot Technique |
title_full |
Detection of Antibodies against Hydatid Cyst Fluid Antigens Using Immunoblot Technique |
title_fullStr |
Detection of Antibodies against Hydatid Cyst Fluid Antigens Using Immunoblot Technique |
title_full_unstemmed |
Detection of Antibodies against Hydatid Cyst Fluid Antigens Using Immunoblot Technique |
title_sort |
detection of antibodies against hydatid cyst fluid antigens using immunoblot technique |
publisher |
Shahid Sadoughi University of Medical Sciences |
series |
Majallah-i Dānishgāh-i ’Ulūm-i Pizishkī-i Shahīd Ṣadūqī Yazd |
issn |
2228-5741 2228-5733 |
publishDate |
2004-07-01 |
description |
Introduction: Immunoblot is recognized as a sensitive and specific serological method for diagnosis of human hydatidosis. To analyze the reactivity of hydatid patients sera with the subunits of 2 major hydatid cyst fluid antigens, ( 5 and B ) immunoblot method was used. Material & Methods:In this regard, 100 sera ,of which 40 sera from patients with surgically diagnosed hydatidosis, 20 sera from patients with parasitic disease other than hydatidosis, 20 sera from patients other than parasitic disease, and 20 sera from healthy controls were examined. Results: For 3 subunits of Ag B (12, 16, 20 kD) the sensitivities were 92.5%, 84.5% and 87.5% respectively and their specificity for all of the 3 subunits was 100%. For 2 subunits of Ag 5, (55, 65 kD) the sensitivity was 100% and the specificities were 100% and 90% respectively . Conclusion: The results indicated that the best subunit for hydatidosis diagnosis is the 55 kD subunit of Ag 5. Meanwhile, a lower reactivity (84.5% of all hydatid sera) was observed with 16 kD subunits of Ag B. |
topic |
Hydatidosis Immunoblot Serology |
url |
http://jssu.ssu.ac.ir/browse.php?a_id=1231&slc_lang=en&sid=1&ftxt=1 |
work_keys_str_mv |
AT fjalosian detectionofantibodiesagainsthydatidcystfluidantigensusingimmunoblottechnique AT azavvaranhosseini detectionofantibodiesagainsthydatidcystfluidantigensusingimmunoblottechnique AT adalimiasl detectionofantibodiesagainsthydatidcystfluidantigensusingimmunoblottechnique AT fghaffarifar detectionofantibodiesagainsthydatidcystfluidantigensusingimmunoblottechnique |
_version_ |
1724872934060720128 |