Detection of Antibodies against Hydatid Cyst Fluid Antigens Using Immunoblot Technique

Introduction: Immunoblot is recognized as a sensitive and specific serological method for diagnosis of human hydatidosis. To analyze the reactivity of hydatid patients sera with the subunits of 2 major hydatid cyst fluid antigens, ( 5 and B ) immunoblot method was used. Material & Methods:In thi...

Full description

Bibliographic Details
Main Authors: F Jalosian, A Zavvaran Hosseini, A Dalimi Asl, F Ghaffari-Far
Format: Article
Language:fas
Published: Shahid Sadoughi University of Medical Sciences 2004-07-01
Series:Majallah-i Dānishgāh-i ’Ulūm-i Pizishkī-i Shahīd Ṣadūqī Yazd
Subjects:
Online Access:http://jssu.ssu.ac.ir/browse.php?a_id=1231&slc_lang=en&sid=1&ftxt=1
id doaj-0957ce13fee840809f7ffd065f2b5179
record_format Article
spelling doaj-0957ce13fee840809f7ffd065f2b51792020-11-25T02:20:13ZfasShahid Sadoughi University of Medical SciencesMajallah-i Dānishgāh-i ’Ulūm-i Pizishkī-i Shahīd Ṣadūqī Yazd2228-57412228-57332004-07-011223338Detection of Antibodies against Hydatid Cyst Fluid Antigens Using Immunoblot TechniqueF JalosianA Zavvaran HosseiniA Dalimi AslF Ghaffari-FarIntroduction: Immunoblot is recognized as a sensitive and specific serological method for diagnosis of human hydatidosis. To analyze the reactivity of hydatid patients sera with the subunits of 2 major hydatid cyst fluid antigens, ( 5 and B ) immunoblot method was used. Material & Methods:In this regard, 100 sera ,of which 40 sera from patients with surgically diagnosed hydatidosis, 20 sera from patients with parasitic disease other than hydatidosis, 20 sera from patients other than parasitic disease, and 20 sera from healthy controls were examined. Results: For 3 subunits of Ag B (12, 16, 20 kD) the sensitivities were 92.5%, 84.5% and 87.5% respectively and their specificity for all of the 3 subunits was 100%. For 2 subunits of Ag 5, (55, 65 kD) the sensitivity was 100% and the specificities were 100% and 90% respectively . Conclusion: The results indicated that the best subunit for hydatidosis diagnosis is the 55 kD subunit of Ag 5. Meanwhile, a lower reactivity (84.5% of all hydatid sera) was observed with 16 kD subunits of Ag B. http://jssu.ssu.ac.ir/browse.php?a_id=1231&slc_lang=en&sid=1&ftxt=1HydatidosisImmunoblotSerology
collection DOAJ
language fas
format Article
sources DOAJ
author F Jalosian
A Zavvaran Hosseini
A Dalimi Asl
F Ghaffari-Far
spellingShingle F Jalosian
A Zavvaran Hosseini
A Dalimi Asl
F Ghaffari-Far
Detection of Antibodies against Hydatid Cyst Fluid Antigens Using Immunoblot Technique
Majallah-i Dānishgāh-i ’Ulūm-i Pizishkī-i Shahīd Ṣadūqī Yazd
Hydatidosis
Immunoblot
Serology
author_facet F Jalosian
A Zavvaran Hosseini
A Dalimi Asl
F Ghaffari-Far
author_sort F Jalosian
title Detection of Antibodies against Hydatid Cyst Fluid Antigens Using Immunoblot Technique
title_short Detection of Antibodies against Hydatid Cyst Fluid Antigens Using Immunoblot Technique
title_full Detection of Antibodies against Hydatid Cyst Fluid Antigens Using Immunoblot Technique
title_fullStr Detection of Antibodies against Hydatid Cyst Fluid Antigens Using Immunoblot Technique
title_full_unstemmed Detection of Antibodies against Hydatid Cyst Fluid Antigens Using Immunoblot Technique
title_sort detection of antibodies against hydatid cyst fluid antigens using immunoblot technique
publisher Shahid Sadoughi University of Medical Sciences
series Majallah-i Dānishgāh-i ’Ulūm-i Pizishkī-i Shahīd Ṣadūqī Yazd
issn 2228-5741
2228-5733
publishDate 2004-07-01
description Introduction: Immunoblot is recognized as a sensitive and specific serological method for diagnosis of human hydatidosis. To analyze the reactivity of hydatid patients sera with the subunits of 2 major hydatid cyst fluid antigens, ( 5 and B ) immunoblot method was used. Material & Methods:In this regard, 100 sera ,of which 40 sera from patients with surgically diagnosed hydatidosis, 20 sera from patients with parasitic disease other than hydatidosis, 20 sera from patients other than parasitic disease, and 20 sera from healthy controls were examined. Results: For 3 subunits of Ag B (12, 16, 20 kD) the sensitivities were 92.5%, 84.5% and 87.5% respectively and their specificity for all of the 3 subunits was 100%. For 2 subunits of Ag 5, (55, 65 kD) the sensitivity was 100% and the specificities were 100% and 90% respectively . Conclusion: The results indicated that the best subunit for hydatidosis diagnosis is the 55 kD subunit of Ag 5. Meanwhile, a lower reactivity (84.5% of all hydatid sera) was observed with 16 kD subunits of Ag B.
topic Hydatidosis
Immunoblot
Serology
url http://jssu.ssu.ac.ir/browse.php?a_id=1231&slc_lang=en&sid=1&ftxt=1
work_keys_str_mv AT fjalosian detectionofantibodiesagainsthydatidcystfluidantigensusingimmunoblottechnique
AT azavvaranhosseini detectionofantibodiesagainsthydatidcystfluidantigensusingimmunoblottechnique
AT adalimiasl detectionofantibodiesagainsthydatidcystfluidantigensusingimmunoblottechnique
AT fghaffarifar detectionofantibodiesagainsthydatidcystfluidantigensusingimmunoblottechnique
_version_ 1724872934060720128