Analysis on voltage characteristics of distribution network considering rolling mill load and Research on control measures

In view of the voltage fluctuation and flicker of distribution network caused by rolling mill type typical load in some distribution networks and the reduction of power quality of power grid, it is necessary to analyze the voltage characteristics of distribution network, and adopt an effective gover...

Full description

Bibliographic Details
Main Authors: Wang Aihua, Zhang Xiaotong, Shi Zhenyu, Wang Shunjiang, Li Dianyang
Format: Article
Language:English
Published: EDP Sciences 2021-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/33/e3sconf_aesee2021_01039.pdf
id doaj-093f0add90524d14b67ec3b66834eccb
record_format Article
spelling doaj-093f0add90524d14b67ec3b66834eccb2021-05-28T12:41:59ZengEDP SciencesE3S Web of Conferences2267-12422021-01-012570103910.1051/e3sconf/202125701039e3sconf_aesee2021_01039Analysis on voltage characteristics of distribution network considering rolling mill load and Research on control measuresWang Aihua0Zhang Xiaotong1Shi Zhenyu2Wang Shunjiang3Li Dianyang4State Grid Liaoning Electric Power Co., Ltd.State Grid Liaoning Electric Power Co., Ltd. Electric Power Research InstituteSchool of Electrical Engineering, Northeast Electric Power UniversityState Grid Liaoning Electric Power Co., Ltd.State Grid Liaoning Electric Power Co., Ltd.In view of the voltage fluctuation and flicker of distribution network caused by rolling mill type typical load in some distribution networks and the reduction of power quality of power grid, it is necessary to analyze the voltage characteristics of distribution network, and adopt an effective governance measure to suppress harmonics in distribution network and improve power quality of power grid. The mathematical models of several typical loads corrected based on the measured data are established, and the influence radiation range of the corrected rolling mill load model on the distribution network voltage is analyzed, and a SVC (static var compensator) governance measure with SOGI phase-locked strategy is adopted for governance. Finally, combined with the actual operation parameters of a substation of State Grid, the power system simulation model is built by using simulation software, and the effectiveness of the governance measures adopted in this paper is verified by simulation analysis.https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/33/e3sconf_aesee2021_01039.pdf
collection DOAJ
language English
format Article
sources DOAJ
author Wang Aihua
Zhang Xiaotong
Shi Zhenyu
Wang Shunjiang
Li Dianyang
spellingShingle Wang Aihua
Zhang Xiaotong
Shi Zhenyu
Wang Shunjiang
Li Dianyang
Analysis on voltage characteristics of distribution network considering rolling mill load and Research on control measures
E3S Web of Conferences
author_facet Wang Aihua
Zhang Xiaotong
Shi Zhenyu
Wang Shunjiang
Li Dianyang
author_sort Wang Aihua
title Analysis on voltage characteristics of distribution network considering rolling mill load and Research on control measures
title_short Analysis on voltage characteristics of distribution network considering rolling mill load and Research on control measures
title_full Analysis on voltage characteristics of distribution network considering rolling mill load and Research on control measures
title_fullStr Analysis on voltage characteristics of distribution network considering rolling mill load and Research on control measures
title_full_unstemmed Analysis on voltage characteristics of distribution network considering rolling mill load and Research on control measures
title_sort analysis on voltage characteristics of distribution network considering rolling mill load and research on control measures
publisher EDP Sciences
series E3S Web of Conferences
issn 2267-1242
publishDate 2021-01-01
description In view of the voltage fluctuation and flicker of distribution network caused by rolling mill type typical load in some distribution networks and the reduction of power quality of power grid, it is necessary to analyze the voltage characteristics of distribution network, and adopt an effective governance measure to suppress harmonics in distribution network and improve power quality of power grid. The mathematical models of several typical loads corrected based on the measured data are established, and the influence radiation range of the corrected rolling mill load model on the distribution network voltage is analyzed, and a SVC (static var compensator) governance measure with SOGI phase-locked strategy is adopted for governance. Finally, combined with the actual operation parameters of a substation of State Grid, the power system simulation model is built by using simulation software, and the effectiveness of the governance measures adopted in this paper is verified by simulation analysis.
url https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/33/e3sconf_aesee2021_01039.pdf
work_keys_str_mv AT wangaihua analysisonvoltagecharacteristicsofdistributionnetworkconsideringrollingmillloadandresearchoncontrolmeasures
AT zhangxiaotong analysisonvoltagecharacteristicsofdistributionnetworkconsideringrollingmillloadandresearchoncontrolmeasures
AT shizhenyu analysisonvoltagecharacteristicsofdistributionnetworkconsideringrollingmillloadandresearchoncontrolmeasures
AT wangshunjiang analysisonvoltagecharacteristicsofdistributionnetworkconsideringrollingmillloadandresearchoncontrolmeasures
AT lidianyang analysisonvoltagecharacteristicsofdistributionnetworkconsideringrollingmillloadandresearchoncontrolmeasures
_version_ 1721423858466029568