Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid

This article presents an analysis and discussion on the performance of a circuit-based model for Compact Fluorescent Lamps (CFL) in a 120V 60Hz power grid. This model is proposed and validated in previous scientific literature for CFLs in 230V 50Hz systems. Nevertheless, the derivation of this model...

Full description

Bibliographic Details
Main Authors: Gabriel Alexis Malagon, Jeisson Bello Peña, Gabriel Ordóñez Plata, Cesar Duarte Gualdrón
Format: Article
Language:English
Published: Universidad Nacional de Colombia 2015-06-01
Series:Ingeniería e Investigación
Subjects:
Online Access:https://revistas.unal.edu.co/index.php/ingeinv/article/view/53618
id doaj-093d12931ab94827b60b7e2715570f01
record_format Article
spelling doaj-093d12931ab94827b60b7e2715570f012020-11-24T21:25:55ZengUniversidad Nacional de ColombiaIngeniería e Investigación0120-56092248-87232015-06-01351Sup899710.15446/ing.investig.v35n1Sup.5361841524Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power gridGabriel Alexis Malagon0Jeisson Bello Peña1Gabriel Ordóñez Plata2Cesar Duarte Gualdrón3PhD Student, UIS, Colombia. Research Group Electric Power Systems, GISEL, Colombia.Young Researcher and Innovator- Colciencias, UIS, Colombia. Research Group Electric Power Systems, GISEL, Colombia.Associate Professor Laureate, Universidad Industrial de Santander, Colombia. Research Group Electric Power Systems, GISEL, Colombia.Associate Professor, Universidad Industrial de Santander, Colombia. Research Group Electric Power Systems, GISEL, Colombia.This article presents an analysis and discussion on the performance of a circuit-based model for Compact Fluorescent Lamps (CFL) in a 120V 60Hz power grid. This model is proposed and validated in previous scientific literature for CFLs in 230V 50Hz systems. Nevertheless, the derivation of this model is not straightforward to follow and its performance in 120V 60Hz systems is a matter of research work. In this paper, the analytical derivation of this CFL model is presented in detail and its performance is discussed when predicting the current of a CFL designed to operate in a 120V 60Hz electrical system. The derived model is separately implemented in both MATLAB® and ATP-EMTP® software using two different sets of parameters previously proposed for 230V 50Hz CFLs. These simulation results are compared against laboratory measurements using a programmable AC voltage source. The measurements and simulations considered seven CFLs 110/127V 60Hz with different power ratings supplied by a sinusoidal (not distorted) voltage source. The simulations under these conditions do not properly predict the current measurements and therefore the set of parameters and/or the model itself need to be adjusted for 120V 60Hz power grids.https://revistas.unal.edu.co/index.php/ingeinv/article/view/53618CFL circuit-based modelharmonics attenuationharmonics diversityharmonic load modelling.
collection DOAJ
language English
format Article
sources DOAJ
author Gabriel Alexis Malagon
Jeisson Bello Peña
Gabriel Ordóñez Plata
Cesar Duarte Gualdrón
spellingShingle Gabriel Alexis Malagon
Jeisson Bello Peña
Gabriel Ordóñez Plata
Cesar Duarte Gualdrón
Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid
Ingeniería e Investigación
CFL circuit-based model
harmonics attenuation
harmonics diversity
harmonic load modelling.
author_facet Gabriel Alexis Malagon
Jeisson Bello Peña
Gabriel Ordóñez Plata
Cesar Duarte Gualdrón
author_sort Gabriel Alexis Malagon
title Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid
title_short Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid
title_full Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid
title_fullStr Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid
title_full_unstemmed Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid
title_sort analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60hz power grid
publisher Universidad Nacional de Colombia
series Ingeniería e Investigación
issn 0120-5609
2248-8723
publishDate 2015-06-01
description This article presents an analysis and discussion on the performance of a circuit-based model for Compact Fluorescent Lamps (CFL) in a 120V 60Hz power grid. This model is proposed and validated in previous scientific literature for CFLs in 230V 50Hz systems. Nevertheless, the derivation of this model is not straightforward to follow and its performance in 120V 60Hz systems is a matter of research work. In this paper, the analytical derivation of this CFL model is presented in detail and its performance is discussed when predicting the current of a CFL designed to operate in a 120V 60Hz electrical system. The derived model is separately implemented in both MATLAB® and ATP-EMTP® software using two different sets of parameters previously proposed for 230V 50Hz CFLs. These simulation results are compared against laboratory measurements using a programmable AC voltage source. The measurements and simulations considered seven CFLs 110/127V 60Hz with different power ratings supplied by a sinusoidal (not distorted) voltage source. The simulations under these conditions do not properly predict the current measurements and therefore the set of parameters and/or the model itself need to be adjusted for 120V 60Hz power grids.
topic CFL circuit-based model
harmonics attenuation
harmonics diversity
harmonic load modelling.
url https://revistas.unal.edu.co/index.php/ingeinv/article/view/53618
work_keys_str_mv AT gabrielalexismalagon analyticalandexperimentaldiscussionofacircuitbasedmodelforcompactfluorescentlampsina60hzpowergrid
AT jeissonbellopena analyticalandexperimentaldiscussionofacircuitbasedmodelforcompactfluorescentlampsina60hzpowergrid
AT gabrielordonezplata analyticalandexperimentaldiscussionofacircuitbasedmodelforcompactfluorescentlampsina60hzpowergrid
AT cesarduartegualdron analyticalandexperimentaldiscussionofacircuitbasedmodelforcompactfluorescentlampsina60hzpowergrid
_version_ 1725981945559515136