Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid
This article presents an analysis and discussion on the performance of a circuit-based model for Compact Fluorescent Lamps (CFL) in a 120V 60Hz power grid. This model is proposed and validated in previous scientific literature for CFLs in 230V 50Hz systems. Nevertheless, the derivation of this model...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universidad Nacional de Colombia
2015-06-01
|
Series: | Ingeniería e Investigación |
Subjects: | |
Online Access: | https://revistas.unal.edu.co/index.php/ingeinv/article/view/53618 |
id |
doaj-093d12931ab94827b60b7e2715570f01 |
---|---|
record_format |
Article |
spelling |
doaj-093d12931ab94827b60b7e2715570f012020-11-24T21:25:55ZengUniversidad Nacional de ColombiaIngeniería e Investigación0120-56092248-87232015-06-01351Sup899710.15446/ing.investig.v35n1Sup.5361841524Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power gridGabriel Alexis Malagon0Jeisson Bello Peña1Gabriel Ordóñez Plata2Cesar Duarte Gualdrón3PhD Student, UIS, Colombia. Research Group Electric Power Systems, GISEL, Colombia.Young Researcher and Innovator- Colciencias, UIS, Colombia. Research Group Electric Power Systems, GISEL, Colombia.Associate Professor Laureate, Universidad Industrial de Santander, Colombia. Research Group Electric Power Systems, GISEL, Colombia.Associate Professor, Universidad Industrial de Santander, Colombia. Research Group Electric Power Systems, GISEL, Colombia.This article presents an analysis and discussion on the performance of a circuit-based model for Compact Fluorescent Lamps (CFL) in a 120V 60Hz power grid. This model is proposed and validated in previous scientific literature for CFLs in 230V 50Hz systems. Nevertheless, the derivation of this model is not straightforward to follow and its performance in 120V 60Hz systems is a matter of research work. In this paper, the analytical derivation of this CFL model is presented in detail and its performance is discussed when predicting the current of a CFL designed to operate in a 120V 60Hz electrical system. The derived model is separately implemented in both MATLAB® and ATP-EMTP® software using two different sets of parameters previously proposed for 230V 50Hz CFLs. These simulation results are compared against laboratory measurements using a programmable AC voltage source. The measurements and simulations considered seven CFLs 110/127V 60Hz with different power ratings supplied by a sinusoidal (not distorted) voltage source. The simulations under these conditions do not properly predict the current measurements and therefore the set of parameters and/or the model itself need to be adjusted for 120V 60Hz power grids.https://revistas.unal.edu.co/index.php/ingeinv/article/view/53618CFL circuit-based modelharmonics attenuationharmonics diversityharmonic load modelling. |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Gabriel Alexis Malagon Jeisson Bello Peña Gabriel Ordóñez Plata Cesar Duarte Gualdrón |
spellingShingle |
Gabriel Alexis Malagon Jeisson Bello Peña Gabriel Ordóñez Plata Cesar Duarte Gualdrón Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid Ingeniería e Investigación CFL circuit-based model harmonics attenuation harmonics diversity harmonic load modelling. |
author_facet |
Gabriel Alexis Malagon Jeisson Bello Peña Gabriel Ordóñez Plata Cesar Duarte Gualdrón |
author_sort |
Gabriel Alexis Malagon |
title |
Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid |
title_short |
Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid |
title_full |
Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid |
title_fullStr |
Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid |
title_full_unstemmed |
Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid |
title_sort |
analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60hz power grid |
publisher |
Universidad Nacional de Colombia |
series |
Ingeniería e Investigación |
issn |
0120-5609 2248-8723 |
publishDate |
2015-06-01 |
description |
This article presents an analysis and discussion on the performance of a circuit-based model for Compact Fluorescent Lamps (CFL) in a 120V 60Hz power grid. This model is proposed and validated in previous scientific literature for CFLs in 230V 50Hz systems. Nevertheless, the derivation of this model is not straightforward to follow and its performance in 120V 60Hz systems is a matter of research work. In this paper, the analytical derivation of this CFL model is presented in detail and its performance is discussed when predicting the current of a CFL designed to operate in a 120V 60Hz electrical system. The derived model is separately implemented in both MATLAB® and ATP-EMTP® software using two different sets of parameters previously proposed for 230V 50Hz CFLs. These simulation results are compared against laboratory measurements using a programmable AC voltage source. The measurements and simulations considered seven CFLs 110/127V 60Hz with different power ratings supplied by a sinusoidal (not distorted) voltage source. The simulations under these conditions do not properly predict the current measurements and therefore the set of parameters and/or the model itself need to be adjusted for 120V 60Hz power grids. |
topic |
CFL circuit-based model harmonics attenuation harmonics diversity harmonic load modelling. |
url |
https://revistas.unal.edu.co/index.php/ingeinv/article/view/53618 |
work_keys_str_mv |
AT gabrielalexismalagon analyticalandexperimentaldiscussionofacircuitbasedmodelforcompactfluorescentlampsina60hzpowergrid AT jeissonbellopena analyticalandexperimentaldiscussionofacircuitbasedmodelforcompactfluorescentlampsina60hzpowergrid AT gabrielordonezplata analyticalandexperimentaldiscussionofacircuitbasedmodelforcompactfluorescentlampsina60hzpowergrid AT cesarduartegualdron analyticalandexperimentaldiscussionofacircuitbasedmodelforcompactfluorescentlampsina60hzpowergrid |