Experimental Comparison of the Diagnostic Accuracy of Conventional and Digital Radiography in Detection of External Root Resorption

Background and Aim: External root resorption is not detectable clinically and radiography plays a key role in its diagnosis.The present study aimed at comparing the diagnostic efficacy of conventional anddigital radiography in detection of simulated root resorption cavities (In-vitro ).   Materials...

Full description

Bibliographic Details
Main Authors: Mahkameh Moshfeghi, Liela Jenab, Sodeh Sarikhani, Sima Nikneshan
Format: Article
Language:English
Published: Islamic Dental Association of Iran 2013-04-01
Series:Journal of Islamic Dental Association of Iran
Subjects:
Online Access:http://jidai.ir/browse.php?a_code=A-10-1-678&slc_lang=en&sid=1
id doaj-088d8051027d4a00aeeb857084fc708a
record_format Article
spelling doaj-088d8051027d4a00aeeb857084fc708a2020-11-25T01:22:19ZengIslamic Dental Association of IranJournal of Islamic Dental Association of Iran2383-30412383-30412013-04-01252129133Experimental Comparison of the Diagnostic Accuracy of Conventional and Digital Radiography in Detection of External Root ResorptionMahkameh Moshfeghi0Liela Jenab1Sodeh Sarikhani2Sima Nikneshan3 Assistant Professor, Department of Oral and Maxillofacial Radiology, School of Dentistry, Shahid Beheshti University of Medical Sciences. Tehran, Iran Dentist Resident, Department of Oral and Maxillofacial Radiology, School of Dentistry, Shahid Beheshti University of Medical Sciences. Tehran, Iran Assistant Professor, Department of Oral and Maxillofacial Radiology, School of Dentistry, Shahid Beheshti University of Medical Sciences. Tehran, Iran Background and Aim: External root resorption is not detectable clinically and radiography plays a key role in its diagnosis.The present study aimed at comparing the diagnostic efficacy of conventional anddigital radiography in detection of simulated root resorption cavities (In-vitro ).   Materials and Methods : This experimental observational study evaluated 39 extracted teeth. All roots, except for the palatal root of upper molars,were hypotheticallydividedinto apical and coronal sections.Half these sites were considered as the control group .Buccal cavities were randomly made in the remaining sectionsusing # 1/2,2 and 4 round burrs.Each tooth was imaged using a CCD-based digital system and E-speed film. Radiographs were taken at 0 and 20˚ mesial angulation .Six image groups were interpreted by two experienced oral and maxillofacial radiologists and one endodontist.Conventional and enhanced digital radiographs were also takenat 0 and 20˚ mesial angulation. Conventional radiographs were viewedat 2X magnification by a magnifying glass. Sensitivity, specificity,false positive and false negative percentages and accuracyof each method were compared with the gold standard. The degree of agreement among these techniques was measuredbykappa coefficient .   Results: Conventional radiography at 2X magnification had the highest sensitivity and specificity. No significant difference was found in sensitivity of digital radiography and enhanced digital radiography. Enhanced digital radiography ranked second in terms of specificity. Conventional radiography at 2X magnification followed by enhanced digital radiography had the highest diagnostic accuracy. Mesial angulation of the cone increasedsensitivity and decreased specificity in all three techniques and thus, it only improved the diagnostic accuracy of digital radiography with no significant effect on the other two techniques.The degree of agreement between the two digital techniques was higher (k=0.68) .   Conclusion: Diagnostic efficacy of conventional radiography at 2X magnification is more than digital radiographs for detection of external root resorption .http://jidai.ir/browse.php?a_code=A-10-1-678&slc_lang=en&sid=1Conventional radiographydigital radiographyroot resorption
collection DOAJ
language English
format Article
sources DOAJ
author Mahkameh Moshfeghi
Liela Jenab
Sodeh Sarikhani
Sima Nikneshan
spellingShingle Mahkameh Moshfeghi
Liela Jenab
Sodeh Sarikhani
Sima Nikneshan
Experimental Comparison of the Diagnostic Accuracy of Conventional and Digital Radiography in Detection of External Root Resorption
Journal of Islamic Dental Association of Iran
Conventional radiography
digital radiography
root resorption
author_facet Mahkameh Moshfeghi
Liela Jenab
Sodeh Sarikhani
Sima Nikneshan
author_sort Mahkameh Moshfeghi
title Experimental Comparison of the Diagnostic Accuracy of Conventional and Digital Radiography in Detection of External Root Resorption
title_short Experimental Comparison of the Diagnostic Accuracy of Conventional and Digital Radiography in Detection of External Root Resorption
title_full Experimental Comparison of the Diagnostic Accuracy of Conventional and Digital Radiography in Detection of External Root Resorption
title_fullStr Experimental Comparison of the Diagnostic Accuracy of Conventional and Digital Radiography in Detection of External Root Resorption
title_full_unstemmed Experimental Comparison of the Diagnostic Accuracy of Conventional and Digital Radiography in Detection of External Root Resorption
title_sort experimental comparison of the diagnostic accuracy of conventional and digital radiography in detection of external root resorption
publisher Islamic Dental Association of Iran
series Journal of Islamic Dental Association of Iran
issn 2383-3041
2383-3041
publishDate 2013-04-01
description Background and Aim: External root resorption is not detectable clinically and radiography plays a key role in its diagnosis.The present study aimed at comparing the diagnostic efficacy of conventional anddigital radiography in detection of simulated root resorption cavities (In-vitro ).   Materials and Methods : This experimental observational study evaluated 39 extracted teeth. All roots, except for the palatal root of upper molars,were hypotheticallydividedinto apical and coronal sections.Half these sites were considered as the control group .Buccal cavities were randomly made in the remaining sectionsusing # 1/2,2 and 4 round burrs.Each tooth was imaged using a CCD-based digital system and E-speed film. Radiographs were taken at 0 and 20˚ mesial angulation .Six image groups were interpreted by two experienced oral and maxillofacial radiologists and one endodontist.Conventional and enhanced digital radiographs were also takenat 0 and 20˚ mesial angulation. Conventional radiographs were viewedat 2X magnification by a magnifying glass. Sensitivity, specificity,false positive and false negative percentages and accuracyof each method were compared with the gold standard. The degree of agreement among these techniques was measuredbykappa coefficient .   Results: Conventional radiography at 2X magnification had the highest sensitivity and specificity. No significant difference was found in sensitivity of digital radiography and enhanced digital radiography. Enhanced digital radiography ranked second in terms of specificity. Conventional radiography at 2X magnification followed by enhanced digital radiography had the highest diagnostic accuracy. Mesial angulation of the cone increasedsensitivity and decreased specificity in all three techniques and thus, it only improved the diagnostic accuracy of digital radiography with no significant effect on the other two techniques.The degree of agreement between the two digital techniques was higher (k=0.68) .   Conclusion: Diagnostic efficacy of conventional radiography at 2X magnification is more than digital radiographs for detection of external root resorption .
topic Conventional radiography
digital radiography
root resorption
url http://jidai.ir/browse.php?a_code=A-10-1-678&slc_lang=en&sid=1
work_keys_str_mv AT mahkamehmoshfeghi experimentalcomparisonofthediagnosticaccuracyofconventionalanddigitalradiographyindetectionofexternalrootresorption
AT lielajenab experimentalcomparisonofthediagnosticaccuracyofconventionalanddigitalradiographyindetectionofexternalrootresorption
AT sodehsarikhani experimentalcomparisonofthediagnosticaccuracyofconventionalanddigitalradiographyindetectionofexternalrootresorption
AT simanikneshan experimentalcomparisonofthediagnosticaccuracyofconventionalanddigitalradiographyindetectionofexternalrootresorption
_version_ 1725126621362388992