Squatting-Related Tibiofemoral Shear Reaction Forces and a Biomechanical Rationale for Femoral Component Loosening

Previous gait studies on squatting have described a rapid reversal in the direction of the tibiofemoral joint shear reaction force when going into a full weight-bearing deep knee flexion squat. The effects of such a shear reversal have not been considered with regard to the loading demand on knee im...

Full description

Bibliographic Details
Main Authors: Ashvin Thambyah, Justin Fernandez
Format: Article
Language:English
Published: Hindawi Limited 2014-01-01
Series:The Scientific World Journal
Online Access:http://dx.doi.org/10.1155/2014/785175
id doaj-088c6925ab7943769ea720e0e4146aba
record_format Article
spelling doaj-088c6925ab7943769ea720e0e4146aba2020-11-24T22:15:14ZengHindawi LimitedThe Scientific World Journal2356-61401537-744X2014-01-01201410.1155/2014/785175785175Squatting-Related Tibiofemoral Shear Reaction Forces and a Biomechanical Rationale for Femoral Component LooseningAshvin Thambyah0Justin Fernandez1Department of Chemical and Materials Engineering, University of Auckland, 20 Symonds Street, Auckland 1142, New ZealandAuckland Bioengineering Institute, University of Auckland, 70 Symonds Street, Auckland 1010, New ZealandPrevious gait studies on squatting have described a rapid reversal in the direction of the tibiofemoral joint shear reaction force when going into a full weight-bearing deep knee flexion squat. The effects of such a shear reversal have not been considered with regard to the loading demand on knee implants in patients whose activities of daily living require frequent squatting. In this paper, the shear reversal effect is discussed and simulated in a finite element knee implant-bone model, to evaluate the possible biomechanical significance of this effect on femoral component loosening of high flexion implants as reported in the literature. The analysis shows that one of the effects of the shear reversal was a switch between large compressive and large tensile principal strains, from knee extension to flexion, respectively, in the region of the anterior flange of the femoral component. Together with the known material limits of cement and bone, this large mismatch in strains as a function of knee position provides new insight into how and why knee implants may fail in patients who perform frequent squatting.http://dx.doi.org/10.1155/2014/785175
collection DOAJ
language English
format Article
sources DOAJ
author Ashvin Thambyah
Justin Fernandez
spellingShingle Ashvin Thambyah
Justin Fernandez
Squatting-Related Tibiofemoral Shear Reaction Forces and a Biomechanical Rationale for Femoral Component Loosening
The Scientific World Journal
author_facet Ashvin Thambyah
Justin Fernandez
author_sort Ashvin Thambyah
title Squatting-Related Tibiofemoral Shear Reaction Forces and a Biomechanical Rationale for Femoral Component Loosening
title_short Squatting-Related Tibiofemoral Shear Reaction Forces and a Biomechanical Rationale for Femoral Component Loosening
title_full Squatting-Related Tibiofemoral Shear Reaction Forces and a Biomechanical Rationale for Femoral Component Loosening
title_fullStr Squatting-Related Tibiofemoral Shear Reaction Forces and a Biomechanical Rationale for Femoral Component Loosening
title_full_unstemmed Squatting-Related Tibiofemoral Shear Reaction Forces and a Biomechanical Rationale for Femoral Component Loosening
title_sort squatting-related tibiofemoral shear reaction forces and a biomechanical rationale for femoral component loosening
publisher Hindawi Limited
series The Scientific World Journal
issn 2356-6140
1537-744X
publishDate 2014-01-01
description Previous gait studies on squatting have described a rapid reversal in the direction of the tibiofemoral joint shear reaction force when going into a full weight-bearing deep knee flexion squat. The effects of such a shear reversal have not been considered with regard to the loading demand on knee implants in patients whose activities of daily living require frequent squatting. In this paper, the shear reversal effect is discussed and simulated in a finite element knee implant-bone model, to evaluate the possible biomechanical significance of this effect on femoral component loosening of high flexion implants as reported in the literature. The analysis shows that one of the effects of the shear reversal was a switch between large compressive and large tensile principal strains, from knee extension to flexion, respectively, in the region of the anterior flange of the femoral component. Together with the known material limits of cement and bone, this large mismatch in strains as a function of knee position provides new insight into how and why knee implants may fail in patients who perform frequent squatting.
url http://dx.doi.org/10.1155/2014/785175
work_keys_str_mv AT ashvinthambyah squattingrelatedtibiofemoralshearreactionforcesandabiomechanicalrationaleforfemoralcomponentloosening
AT justinfernandez squattingrelatedtibiofemoralshearreactionforcesandabiomechanicalrationaleforfemoralcomponentloosening
_version_ 1725795301508251648