Adaptive Control Algorithm of the Synchronous Generator

The article discusses the the problem of controlling a synchronous generator, namely, maintaining the stability of the control object in the conditions of occurrence of noise and disturbances in the regulatory process. The model of a synchronous generator is represented by a system of differential e...

Full description

Bibliographic Details
Main Authors: Shevchenko Victor, Pshikhopov Viacheslav, Medvedev Mikhail
Format: Article
Language:English
Published: EDP Sciences 2017-01-01
Series:MATEC Web of Conferences
Online Access:https://doi.org/10.1051/matecconf/20179513002
id doaj-07f73b811e284e46b1d221f2029381d4
record_format Article
spelling doaj-07f73b811e284e46b1d221f2029381d42021-02-02T07:32:01ZengEDP SciencesMATEC Web of Conferences2261-236X2017-01-01951300210.1051/matecconf/20179513002matecconf_icmme2017_13002Adaptive Control Algorithm of the Synchronous GeneratorShevchenko VictorPshikhopov ViacheslavMedvedev MikhailThe article discusses the the problem of controlling a synchronous generator, namely, maintaining the stability of the control object in the conditions of occurrence of noise and disturbances in the regulatory process. The model of a synchronous generator is represented by a system of differential equations of Park-Gorev, where state variables are computed relative to synchronously rotating d, q-axis. Management of synchronous generator is proposed to organize on the basis of the position-path control using algorithms to adapt with the reference model. Basic control law directed on the stabilizing indicators the frequency generated by the current and the required power level, which is achieved by controlling the mechanical torque on the shaft of the turbine and the value of the excitation voltage of the synchronous generator. Modification of the classic adaptation algorithm using the reference model, allowing to minimize the error of the reference regulation and the model under investigation within the prescribed limits, produced by means of the introduction of additional variables controller adaptation in the model. Сarried out the mathematical modeling of control provided influence on the studied model of continuous nonlinear and unmeasured the disturbance. Simulation results confirm the high level accuracy of tracking and adaptation investigated model with respect to the reference, and the present value of the loop error depends on parameters performance of regulator.https://doi.org/10.1051/matecconf/20179513002
collection DOAJ
language English
format Article
sources DOAJ
author Shevchenko Victor
Pshikhopov Viacheslav
Medvedev Mikhail
spellingShingle Shevchenko Victor
Pshikhopov Viacheslav
Medvedev Mikhail
Adaptive Control Algorithm of the Synchronous Generator
MATEC Web of Conferences
author_facet Shevchenko Victor
Pshikhopov Viacheslav
Medvedev Mikhail
author_sort Shevchenko Victor
title Adaptive Control Algorithm of the Synchronous Generator
title_short Adaptive Control Algorithm of the Synchronous Generator
title_full Adaptive Control Algorithm of the Synchronous Generator
title_fullStr Adaptive Control Algorithm of the Synchronous Generator
title_full_unstemmed Adaptive Control Algorithm of the Synchronous Generator
title_sort adaptive control algorithm of the synchronous generator
publisher EDP Sciences
series MATEC Web of Conferences
issn 2261-236X
publishDate 2017-01-01
description The article discusses the the problem of controlling a synchronous generator, namely, maintaining the stability of the control object in the conditions of occurrence of noise and disturbances in the regulatory process. The model of a synchronous generator is represented by a system of differential equations of Park-Gorev, where state variables are computed relative to synchronously rotating d, q-axis. Management of synchronous generator is proposed to organize on the basis of the position-path control using algorithms to adapt with the reference model. Basic control law directed on the stabilizing indicators the frequency generated by the current and the required power level, which is achieved by controlling the mechanical torque on the shaft of the turbine and the value of the excitation voltage of the synchronous generator. Modification of the classic adaptation algorithm using the reference model, allowing to minimize the error of the reference regulation and the model under investigation within the prescribed limits, produced by means of the introduction of additional variables controller adaptation in the model. Сarried out the mathematical modeling of control provided influence on the studied model of continuous nonlinear and unmeasured the disturbance. Simulation results confirm the high level accuracy of tracking and adaptation investigated model with respect to the reference, and the present value of the loop error depends on parameters performance of regulator.
url https://doi.org/10.1051/matecconf/20179513002
work_keys_str_mv AT shevchenkovictor adaptivecontrolalgorithmofthesynchronousgenerator
AT pshikhopovviacheslav adaptivecontrolalgorithmofthesynchronousgenerator
AT medvedevmikhail adaptivecontrolalgorithmofthesynchronousgenerator
_version_ 1724299201230143488