Performance Analysis of Disposable Flow Cell for Nitrite Detection
This paper describes the work on the development of disposable micro sample cell for optical spectroscopy. The disposable flow cell is an attractive approach to ensure cleanliness of the sample container and to avoid contamination between samples and residual detergents. The main objective of this w...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
IEEE
2019-01-01
|
Series: | IEEE Access |
Subjects: | |
Online Access: | https://ieeexplore.ieee.org/document/8863888/ |
id |
doaj-07dabd929e594f56b03908a8ceb44bbc |
---|---|
record_format |
Article |
spelling |
doaj-07dabd929e594f56b03908a8ceb44bbc2021-03-30T00:34:51ZengIEEEIEEE Access2169-35362019-01-01714602414603610.1109/ACCESS.2019.29461918863888Performance Analysis of Disposable Flow Cell for Nitrite DetectionSabiran Abubakar0https://orcid.org/0000-0003-0842-1339Norhana Arsad1Abang Annuar Ehsan2Azura Hamzah3Nur Hazliza Ariffin4Mohammad Syuhaimi Ab-Rahman5Department of Electronic Systems Engineering, Malaysia-Japan International Institute of Technology, UTM, Kuala Lumpur, MalaysiaCenter of Advanced Electronic and Communication Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, Bangi, MalaysiaInstitute of Microengineering and Nanoelectronics (IMEN), Universiti Kebangsaan Malaysia, Bangi, MalaysiaDepartment of Electronic Systems Engineering, Malaysia-Japan International Institute of Technology, UTM, Kuala Lumpur, MalaysiaSchool of Engineering, Monash University Malaysia, Subang Jaya, MalaysiaCenter of Advanced Electronic and Communication Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, Bangi, MalaysiaThis paper describes the work on the development of disposable micro sample cell for optical spectroscopy. The disposable flow cell is an attractive approach to ensure cleanliness of the sample container and to avoid contamination between samples and residual detergents. The main objective of this work is to develop a disposable flow cell made of Poly-(methyl methacrylate) (PMMA) with polymer optical fiber (POF) connections that is easy to install and has a performance measurement that meets ISO standards. The research involved three stages namely fiber optic preparation, design of the flow cell and analysis of the flow cell design. Chemometrics methods, internal quality control standards, calibration and performance characterization instruments are used for the analysis. The POF fiber performance is described by a linear calibration graph. The Shewhart chart for uncertainty analysis shows no data out of the chart, with mean value meeting the ISO 8258 standard. Comparisons of the calibration to other disposable sample cells show better results in linearity. Chemometrics analysis specified the reading data to be within the warning line in accordance with ISO 8258. Validation of the mathematical model is acceptable as none exceed 95% for the F-test. Average precision and sensitivity are 0.9 and 0.3, respectively. Limit of detection and limit of quantification are 0.07 and 0.25, respectively. Based on the results, the design of a disposable flow cell with POF fiber meets the standards of analysis for sample containers used in a spectrometer.https://ieeexplore.ieee.org/document/8863888/Absorptioncontrol chartISO standardpolymerssensorsspectroscopy |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Sabiran Abubakar Norhana Arsad Abang Annuar Ehsan Azura Hamzah Nur Hazliza Ariffin Mohammad Syuhaimi Ab-Rahman |
spellingShingle |
Sabiran Abubakar Norhana Arsad Abang Annuar Ehsan Azura Hamzah Nur Hazliza Ariffin Mohammad Syuhaimi Ab-Rahman Performance Analysis of Disposable Flow Cell for Nitrite Detection IEEE Access Absorption control chart ISO standard polymers sensors spectroscopy |
author_facet |
Sabiran Abubakar Norhana Arsad Abang Annuar Ehsan Azura Hamzah Nur Hazliza Ariffin Mohammad Syuhaimi Ab-Rahman |
author_sort |
Sabiran Abubakar |
title |
Performance Analysis of Disposable Flow Cell for Nitrite Detection |
title_short |
Performance Analysis of Disposable Flow Cell for Nitrite Detection |
title_full |
Performance Analysis of Disposable Flow Cell for Nitrite Detection |
title_fullStr |
Performance Analysis of Disposable Flow Cell for Nitrite Detection |
title_full_unstemmed |
Performance Analysis of Disposable Flow Cell for Nitrite Detection |
title_sort |
performance analysis of disposable flow cell for nitrite detection |
publisher |
IEEE |
series |
IEEE Access |
issn |
2169-3536 |
publishDate |
2019-01-01 |
description |
This paper describes the work on the development of disposable micro sample cell for optical spectroscopy. The disposable flow cell is an attractive approach to ensure cleanliness of the sample container and to avoid contamination between samples and residual detergents. The main objective of this work is to develop a disposable flow cell made of Poly-(methyl methacrylate) (PMMA) with polymer optical fiber (POF) connections that is easy to install and has a performance measurement that meets ISO standards. The research involved three stages namely fiber optic preparation, design of the flow cell and analysis of the flow cell design. Chemometrics methods, internal quality control standards, calibration and performance characterization instruments are used for the analysis. The POF fiber performance is described by a linear calibration graph. The Shewhart chart for uncertainty analysis shows no data out of the chart, with mean value meeting the ISO 8258 standard. Comparisons of the calibration to other disposable sample cells show better results in linearity. Chemometrics analysis specified the reading data to be within the warning line in accordance with ISO 8258. Validation of the mathematical model is acceptable as none exceed 95% for the F-test. Average precision and sensitivity are 0.9 and 0.3, respectively. Limit of detection and limit of quantification are 0.07 and 0.25, respectively. Based on the results, the design of a disposable flow cell with POF fiber meets the standards of analysis for sample containers used in a spectrometer. |
topic |
Absorption control chart ISO standard polymers sensors spectroscopy |
url |
https://ieeexplore.ieee.org/document/8863888/ |
work_keys_str_mv |
AT sabiranabubakar performanceanalysisofdisposableflowcellfornitritedetection AT norhanaarsad performanceanalysisofdisposableflowcellfornitritedetection AT abangannuarehsan performanceanalysisofdisposableflowcellfornitritedetection AT azurahamzah performanceanalysisofdisposableflowcellfornitritedetection AT nurhazlizaariffin performanceanalysisofdisposableflowcellfornitritedetection AT mohammadsyuhaimiabrahman performanceanalysisofdisposableflowcellfornitritedetection |
_version_ |
1724188087328702464 |