Comparison between Dual-Energy X-ray Absorptiometry and Bioelectrical Impedance Analyses for Accuracy in Measuring Whole Body Muscle Mass and Appendicular Skeletal Muscle Mass

We evaluate the accuracy of whole body muscle mass (WBMM) and appendicular skeletal muscle mass (ASMM) assessed by bioelectrical impedance analysis (BIA) using an InBody770 machine (InBody, Seoul, Korea) referenced to dual-energy X-ray absorptiometry (DXA) in 507 people (mean age 63.7 ± 1...

Full description

Bibliographic Details
Main Authors: Seo Young Lee, Soyeon Ahn, Young Ji Kim, Myoung Jin Ji, Kyoung Min Kim, Sung Hee Choi, Hak Chul Jang, Soo Lim
Format: Article
Language:English
Published: MDPI AG 2018-06-01
Series:Nutrients
Subjects:
Online Access:http://www.mdpi.com/2072-6643/10/6/738
id doaj-0790aaccae9f4ebd849d02b419150a3e
record_format Article
spelling doaj-0790aaccae9f4ebd849d02b419150a3e2020-11-24T21:46:02ZengMDPI AGNutrients2072-66432018-06-0110673810.3390/nu10060738nu10060738Comparison between Dual-Energy X-ray Absorptiometry and Bioelectrical Impedance Analyses for Accuracy in Measuring Whole Body Muscle Mass and Appendicular Skeletal Muscle MassSeo Young Lee0Soyeon Ahn1Young Ji Kim2Myoung Jin Ji3Kyoung Min Kim4Sung Hee Choi5Hak Chul Jang6Soo Lim7Department of Internal Medicine, Seoul National University College of Medicine and Seoul National University Bundang Hospital, Seongnam 13620, KoreaDivision of Statistics, Medical Research Collaborating Center, Seoul National University Bundang Hospital, Seongnam 13620, KoreaDepartment of Internal Medicine, Seoul National University College of Medicine and Seoul National University Bundang Hospital, Seongnam 13620, KoreaDepartment of Internal Medicine, Seoul National University College of Medicine and Seoul National University Bundang Hospital, Seongnam 13620, KoreaDepartment of Internal Medicine, Seoul National University College of Medicine and Seoul National University Bundang Hospital, Seongnam 13620, KoreaDepartment of Internal Medicine, Seoul National University College of Medicine and Seoul National University Bundang Hospital, Seongnam 13620, KoreaDepartment of Internal Medicine, Seoul National University College of Medicine and Seoul National University Bundang Hospital, Seongnam 13620, KoreaDepartment of Internal Medicine, Seoul National University College of Medicine and Seoul National University Bundang Hospital, Seongnam 13620, KoreaWe evaluate the accuracy of whole body muscle mass (WBMM) and appendicular skeletal muscle mass (ASMM) assessed by bioelectrical impedance analysis (BIA) using an InBody770 machine (InBody, Seoul, Korea) referenced to dual-energy X-ray absorptiometry (DXA) in 507 people (mean age 63.7 ± 10.8 years, body mass index (BMI) 25.2 ± 3.5 kg/m2). Mean WBMMs measured by BIA and DXA were 49.3 ± 6.6 kg and 46.8 ± 6.5 kg in men and 36.1 ± 4.7 kg and 34.0 ± 4.8 kg in women, respectively. The respective effect sizes and 95% confidence intervals (CIs) for the difference were 2.49 (2.22–2.76) for men, and 2.12 (1.91–2.33) for women. Mean ASMMs measured by BIA and DXA were 22.1 ± 3.3 kg and 19.9 ± 3.2 kg in men, and 15.3 ± 2.5 kg and 13.5 ± 2.2 kg in women, respectively. The respective effect sizes and 95% CIs for the difference were 2.26 (2.10–2.41) for men and 1.75 (1.65–1.87) for women. The BIA clearly overestimated WBMM by 2.28 kg and ASMM by 1.97 kg compared with DXA. Using BMI, gender, and fat percentage, we derive equations that improved the residuals to <2 kg between methods from 38.29% to 85.91% for WBMM and 52.78% to 97.02% for ASMM.http://www.mdpi.com/2072-6643/10/6/738bioelectrical impedance analysisdual-energy X-ray absorptiometrymuscle mass
collection DOAJ
language English
format Article
sources DOAJ
author Seo Young Lee
Soyeon Ahn
Young Ji Kim
Myoung Jin Ji
Kyoung Min Kim
Sung Hee Choi
Hak Chul Jang
Soo Lim
spellingShingle Seo Young Lee
Soyeon Ahn
Young Ji Kim
Myoung Jin Ji
Kyoung Min Kim
Sung Hee Choi
Hak Chul Jang
Soo Lim
Comparison between Dual-Energy X-ray Absorptiometry and Bioelectrical Impedance Analyses for Accuracy in Measuring Whole Body Muscle Mass and Appendicular Skeletal Muscle Mass
Nutrients
bioelectrical impedance analysis
dual-energy X-ray absorptiometry
muscle mass
author_facet Seo Young Lee
Soyeon Ahn
Young Ji Kim
Myoung Jin Ji
Kyoung Min Kim
Sung Hee Choi
Hak Chul Jang
Soo Lim
author_sort Seo Young Lee
title Comparison between Dual-Energy X-ray Absorptiometry and Bioelectrical Impedance Analyses for Accuracy in Measuring Whole Body Muscle Mass and Appendicular Skeletal Muscle Mass
title_short Comparison between Dual-Energy X-ray Absorptiometry and Bioelectrical Impedance Analyses for Accuracy in Measuring Whole Body Muscle Mass and Appendicular Skeletal Muscle Mass
title_full Comparison between Dual-Energy X-ray Absorptiometry and Bioelectrical Impedance Analyses for Accuracy in Measuring Whole Body Muscle Mass and Appendicular Skeletal Muscle Mass
title_fullStr Comparison between Dual-Energy X-ray Absorptiometry and Bioelectrical Impedance Analyses for Accuracy in Measuring Whole Body Muscle Mass and Appendicular Skeletal Muscle Mass
title_full_unstemmed Comparison between Dual-Energy X-ray Absorptiometry and Bioelectrical Impedance Analyses for Accuracy in Measuring Whole Body Muscle Mass and Appendicular Skeletal Muscle Mass
title_sort comparison between dual-energy x-ray absorptiometry and bioelectrical impedance analyses for accuracy in measuring whole body muscle mass and appendicular skeletal muscle mass
publisher MDPI AG
series Nutrients
issn 2072-6643
publishDate 2018-06-01
description We evaluate the accuracy of whole body muscle mass (WBMM) and appendicular skeletal muscle mass (ASMM) assessed by bioelectrical impedance analysis (BIA) using an InBody770 machine (InBody, Seoul, Korea) referenced to dual-energy X-ray absorptiometry (DXA) in 507 people (mean age 63.7 ± 10.8 years, body mass index (BMI) 25.2 ± 3.5 kg/m2). Mean WBMMs measured by BIA and DXA were 49.3 ± 6.6 kg and 46.8 ± 6.5 kg in men and 36.1 ± 4.7 kg and 34.0 ± 4.8 kg in women, respectively. The respective effect sizes and 95% confidence intervals (CIs) for the difference were 2.49 (2.22–2.76) for men, and 2.12 (1.91–2.33) for women. Mean ASMMs measured by BIA and DXA were 22.1 ± 3.3 kg and 19.9 ± 3.2 kg in men, and 15.3 ± 2.5 kg and 13.5 ± 2.2 kg in women, respectively. The respective effect sizes and 95% CIs for the difference were 2.26 (2.10–2.41) for men and 1.75 (1.65–1.87) for women. The BIA clearly overestimated WBMM by 2.28 kg and ASMM by 1.97 kg compared with DXA. Using BMI, gender, and fat percentage, we derive equations that improved the residuals to <2 kg between methods from 38.29% to 85.91% for WBMM and 52.78% to 97.02% for ASMM.
topic bioelectrical impedance analysis
dual-energy X-ray absorptiometry
muscle mass
url http://www.mdpi.com/2072-6643/10/6/738
work_keys_str_mv AT seoyounglee comparisonbetweendualenergyxrayabsorptiometryandbioelectricalimpedanceanalysesforaccuracyinmeasuringwholebodymusclemassandappendicularskeletalmusclemass
AT soyeonahn comparisonbetweendualenergyxrayabsorptiometryandbioelectricalimpedanceanalysesforaccuracyinmeasuringwholebodymusclemassandappendicularskeletalmusclemass
AT youngjikim comparisonbetweendualenergyxrayabsorptiometryandbioelectricalimpedanceanalysesforaccuracyinmeasuringwholebodymusclemassandappendicularskeletalmusclemass
AT myoungjinji comparisonbetweendualenergyxrayabsorptiometryandbioelectricalimpedanceanalysesforaccuracyinmeasuringwholebodymusclemassandappendicularskeletalmusclemass
AT kyoungminkim comparisonbetweendualenergyxrayabsorptiometryandbioelectricalimpedanceanalysesforaccuracyinmeasuringwholebodymusclemassandappendicularskeletalmusclemass
AT sungheechoi comparisonbetweendualenergyxrayabsorptiometryandbioelectricalimpedanceanalysesforaccuracyinmeasuringwholebodymusclemassandappendicularskeletalmusclemass
AT hakchuljang comparisonbetweendualenergyxrayabsorptiometryandbioelectricalimpedanceanalysesforaccuracyinmeasuringwholebodymusclemassandappendicularskeletalmusclemass
AT soolim comparisonbetweendualenergyxrayabsorptiometryandbioelectricalimpedanceanalysesforaccuracyinmeasuringwholebodymusclemassandappendicularskeletalmusclemass
_version_ 1725902474848501760