Theoretical and experimental analysis of dynamic processes of pipe branch for supply water to the Pelton turbine

The paper presents the results of the analysis of pipe branch A6 to feed the Hydropower Plant ”Perućica” with integrated action Pelton turbines. The analysis was conducted experimentally (tensometric) and numerically. The basis of the experimental research is the numerical finite element analysis...

Full description

Bibliographic Details
Main Authors: Jovanović Miomir Lj., Milenković Dragica R., Petrović Goran S., Milić Predrag Đ., Milanović Saša M.
Format: Article
Language:English
Published: VINCA Institute of Nuclear Sciences 2012-01-01
Series:Thermal Science
Subjects:
Online Access:http://www.doiserbia.nb.rs/img/doi/0354-9836/2012/0354-98361200196J.pdf