A randomised pilot equivalence trial to evaluate diamagnetically enhanced transdermal delivery of key ground substance components in comparison to an established transdermal non-steroidal anti-inflammatory formulation in males with prior knee injury.

<h4>Objective</h4>This pilot study assessed the efficacy of a knee guard device, which used magnetophoresis to transdermally deliver Glucosamine, Chondroitin and Hyaluronic Acid in a cohort of individuals with prior knee injury. The aim was to determine if the change in physical function...

Full description

Bibliographic Details
Main Authors: Bill Vicenzino, Peter Lawrenson, Asaduzzaman Khan, Aiofe Stephenson, Luke Heales, Heather A E Benson, Anthony Wright
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2019-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0211999
id doaj-071fc30fb01942e689eac27009d91f90
record_format Article
spelling doaj-071fc30fb01942e689eac27009d91f902021-03-04T10:36:15ZengPublic Library of Science (PLoS)PLoS ONE1932-62032019-01-01142e021199910.1371/journal.pone.0211999A randomised pilot equivalence trial to evaluate diamagnetically enhanced transdermal delivery of key ground substance components in comparison to an established transdermal non-steroidal anti-inflammatory formulation in males with prior knee injury.Bill VicenzinoPeter LawrensonAsaduzzaman KhanAiofe StephensonLuke HealesHeather A E BensonAnthony Wright<h4>Objective</h4>This pilot study assessed the efficacy of a knee guard device, which used magnetophoresis to transdermally deliver Glucosamine, Chondroitin and Hyaluronic Acid in a cohort of individuals with prior knee injury. The aim was to determine if the change in physical function and pain with the knee guard device was equivalent to the change produced by an established topical NSAID formulation containing diclofenac sodium 1%.<h4>Methods</h4>A randomized, controlled, equivalence trial evaluated outcomes following treatment with the knee guard device or NSAID formulation. The study recruited 114 male participants (aged 40-55 years). Participants were randomly allocated to wear the knee guard device or to use a NSAID gel daily for two weeks. The primary outcomes were the knee injury osteoarthritis function score (KOOS-F) and an aggregated function score (AFS). The lower extremity functional scale (LEFS), pain numerical rating scale (PNRS), global rating of change (GROC) and other KOOS scores were also evaluated.<h4>Results</h4>Multiple linear regression analyses indicated that there were no significant differences between the interventions for changes in the primary outcomes of AFS and KOOS_F. The 95% confidence interval (-2.89 to 5.15) of the estimated treatment difference for KOOS-F was within the lower (-5.61) and upper (5.61) bounds of the 7% equivalence margin for that measure, The mean value for the AFS was within, but the 95% CI (-3.11 to 7.37) exceeded the 7% equivalence margin (-2.97 to 2.97) for that measure. There was a significant difference in PNRS, which favored the knee guard device.<h4>Conclusion</h4>The knee guard device demonstrated equivalence for the KOOS-F measure but not the AFS measure of function over the two week trial period when compared to a widely available NSAID gel that has been shown to be superior to placebo. The knee guard produced a greater reduction in pain report (p = 0.002) than the NSAID gel. Users of the knee guard device experienced more skin irritation than participants using the NSAID gel. Further research is required to fully evaluate the therapeutic potential of this innovative treatment approach.https://doi.org/10.1371/journal.pone.0211999
collection DOAJ
language English
format Article
sources DOAJ
author Bill Vicenzino
Peter Lawrenson
Asaduzzaman Khan
Aiofe Stephenson
Luke Heales
Heather A E Benson
Anthony Wright
spellingShingle Bill Vicenzino
Peter Lawrenson
Asaduzzaman Khan
Aiofe Stephenson
Luke Heales
Heather A E Benson
Anthony Wright
A randomised pilot equivalence trial to evaluate diamagnetically enhanced transdermal delivery of key ground substance components in comparison to an established transdermal non-steroidal anti-inflammatory formulation in males with prior knee injury.
PLoS ONE
author_facet Bill Vicenzino
Peter Lawrenson
Asaduzzaman Khan
Aiofe Stephenson
Luke Heales
Heather A E Benson
Anthony Wright
author_sort Bill Vicenzino
title A randomised pilot equivalence trial to evaluate diamagnetically enhanced transdermal delivery of key ground substance components in comparison to an established transdermal non-steroidal anti-inflammatory formulation in males with prior knee injury.
title_short A randomised pilot equivalence trial to evaluate diamagnetically enhanced transdermal delivery of key ground substance components in comparison to an established transdermal non-steroidal anti-inflammatory formulation in males with prior knee injury.
title_full A randomised pilot equivalence trial to evaluate diamagnetically enhanced transdermal delivery of key ground substance components in comparison to an established transdermal non-steroidal anti-inflammatory formulation in males with prior knee injury.
title_fullStr A randomised pilot equivalence trial to evaluate diamagnetically enhanced transdermal delivery of key ground substance components in comparison to an established transdermal non-steroidal anti-inflammatory formulation in males with prior knee injury.
title_full_unstemmed A randomised pilot equivalence trial to evaluate diamagnetically enhanced transdermal delivery of key ground substance components in comparison to an established transdermal non-steroidal anti-inflammatory formulation in males with prior knee injury.
title_sort randomised pilot equivalence trial to evaluate diamagnetically enhanced transdermal delivery of key ground substance components in comparison to an established transdermal non-steroidal anti-inflammatory formulation in males with prior knee injury.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2019-01-01
description <h4>Objective</h4>This pilot study assessed the efficacy of a knee guard device, which used magnetophoresis to transdermally deliver Glucosamine, Chondroitin and Hyaluronic Acid in a cohort of individuals with prior knee injury. The aim was to determine if the change in physical function and pain with the knee guard device was equivalent to the change produced by an established topical NSAID formulation containing diclofenac sodium 1%.<h4>Methods</h4>A randomized, controlled, equivalence trial evaluated outcomes following treatment with the knee guard device or NSAID formulation. The study recruited 114 male participants (aged 40-55 years). Participants were randomly allocated to wear the knee guard device or to use a NSAID gel daily for two weeks. The primary outcomes were the knee injury osteoarthritis function score (KOOS-F) and an aggregated function score (AFS). The lower extremity functional scale (LEFS), pain numerical rating scale (PNRS), global rating of change (GROC) and other KOOS scores were also evaluated.<h4>Results</h4>Multiple linear regression analyses indicated that there were no significant differences between the interventions for changes in the primary outcomes of AFS and KOOS_F. The 95% confidence interval (-2.89 to 5.15) of the estimated treatment difference for KOOS-F was within the lower (-5.61) and upper (5.61) bounds of the 7% equivalence margin for that measure, The mean value for the AFS was within, but the 95% CI (-3.11 to 7.37) exceeded the 7% equivalence margin (-2.97 to 2.97) for that measure. There was a significant difference in PNRS, which favored the knee guard device.<h4>Conclusion</h4>The knee guard device demonstrated equivalence for the KOOS-F measure but not the AFS measure of function over the two week trial period when compared to a widely available NSAID gel that has been shown to be superior to placebo. The knee guard produced a greater reduction in pain report (p = 0.002) than the NSAID gel. Users of the knee guard device experienced more skin irritation than participants using the NSAID gel. Further research is required to fully evaluate the therapeutic potential of this innovative treatment approach.
url https://doi.org/10.1371/journal.pone.0211999
work_keys_str_mv AT billvicenzino arandomisedpilotequivalencetrialtoevaluatediamagneticallyenhancedtransdermaldeliveryofkeygroundsubstancecomponentsincomparisontoanestablishedtransdermalnonsteroidalantiinflammatoryformulationinmaleswithpriorkneeinjury
AT peterlawrenson arandomisedpilotequivalencetrialtoevaluatediamagneticallyenhancedtransdermaldeliveryofkeygroundsubstancecomponentsincomparisontoanestablishedtransdermalnonsteroidalantiinflammatoryformulationinmaleswithpriorkneeinjury
AT asaduzzamankhan arandomisedpilotequivalencetrialtoevaluatediamagneticallyenhancedtransdermaldeliveryofkeygroundsubstancecomponentsincomparisontoanestablishedtransdermalnonsteroidalantiinflammatoryformulationinmaleswithpriorkneeinjury
AT aiofestephenson arandomisedpilotequivalencetrialtoevaluatediamagneticallyenhancedtransdermaldeliveryofkeygroundsubstancecomponentsincomparisontoanestablishedtransdermalnonsteroidalantiinflammatoryformulationinmaleswithpriorkneeinjury
AT lukeheales arandomisedpilotequivalencetrialtoevaluatediamagneticallyenhancedtransdermaldeliveryofkeygroundsubstancecomponentsincomparisontoanestablishedtransdermalnonsteroidalantiinflammatoryformulationinmaleswithpriorkneeinjury
AT heatheraebenson arandomisedpilotequivalencetrialtoevaluatediamagneticallyenhancedtransdermaldeliveryofkeygroundsubstancecomponentsincomparisontoanestablishedtransdermalnonsteroidalantiinflammatoryformulationinmaleswithpriorkneeinjury
AT anthonywright arandomisedpilotequivalencetrialtoevaluatediamagneticallyenhancedtransdermaldeliveryofkeygroundsubstancecomponentsincomparisontoanestablishedtransdermalnonsteroidalantiinflammatoryformulationinmaleswithpriorkneeinjury
AT billvicenzino randomisedpilotequivalencetrialtoevaluatediamagneticallyenhancedtransdermaldeliveryofkeygroundsubstancecomponentsincomparisontoanestablishedtransdermalnonsteroidalantiinflammatoryformulationinmaleswithpriorkneeinjury
AT peterlawrenson randomisedpilotequivalencetrialtoevaluatediamagneticallyenhancedtransdermaldeliveryofkeygroundsubstancecomponentsincomparisontoanestablishedtransdermalnonsteroidalantiinflammatoryformulationinmaleswithpriorkneeinjury
AT asaduzzamankhan randomisedpilotequivalencetrialtoevaluatediamagneticallyenhancedtransdermaldeliveryofkeygroundsubstancecomponentsincomparisontoanestablishedtransdermalnonsteroidalantiinflammatoryformulationinmaleswithpriorkneeinjury
AT aiofestephenson randomisedpilotequivalencetrialtoevaluatediamagneticallyenhancedtransdermaldeliveryofkeygroundsubstancecomponentsincomparisontoanestablishedtransdermalnonsteroidalantiinflammatoryformulationinmaleswithpriorkneeinjury
AT lukeheales randomisedpilotequivalencetrialtoevaluatediamagneticallyenhancedtransdermaldeliveryofkeygroundsubstancecomponentsincomparisontoanestablishedtransdermalnonsteroidalantiinflammatoryformulationinmaleswithpriorkneeinjury
AT heatheraebenson randomisedpilotequivalencetrialtoevaluatediamagneticallyenhancedtransdermaldeliveryofkeygroundsubstancecomponentsincomparisontoanestablishedtransdermalnonsteroidalantiinflammatoryformulationinmaleswithpriorkneeinjury
AT anthonywright randomisedpilotequivalencetrialtoevaluatediamagneticallyenhancedtransdermaldeliveryofkeygroundsubstancecomponentsincomparisontoanestablishedtransdermalnonsteroidalantiinflammatoryformulationinmaleswithpriorkneeinjury
_version_ 1714805190367903744