Evaluation of a Novel Manikin-Based Amniotomy Simulator
Objective: To evaluate satisfaction of a novel manikin-based amniotomy simulator by obstetricians and medical students. Material and Methods: The simulator was designed to simulate pregnant women in the active phase of labor with a 3-cm cervical dilatation, 100% effacement, and intact fetal membrane...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Prince of Songkla University
2015-12-01
|
Series: | Journal of Health Science and Medical Research (JHSMR) |
Subjects: | |
Online Access: | https://www.jhsmr.org/index.php/jhsmr/article/view/194 |
id |
doaj-06e9b47a83f5473684a6550747740d5d |
---|---|
record_format |
Article |
spelling |
doaj-06e9b47a83f5473684a6550747740d5d2020-11-25T02:25:42ZengPrince of Songkla UniversityJournal of Health Science and Medical Research (JHSMR)2586-99812630-05592015-12-01336277284208Evaluation of a Novel Manikin-Based Amniotomy SimulatorSirirat Thomrongwat0Hatern Tintara1Department of Obstetrics and Gynecology, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla 90110,Department of Obstetrics and Gynecology, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla 90110,Objective: To evaluate satisfaction of a novel manikin-based amniotomy simulator by obstetricians and medical students. Material and Methods: The simulator was designed to simulate pregnant women in the active phase of labor with a 3-cm cervical dilatation, 100% effacement, and intact fetal membrane. The simulator consists of an amniotomy box inserted inside a pelvic training model. The front opening of amniotomy box is covered with 1.5-mm thick rubber sheet with a 3-cm diameter central hole. The upper opening is for loading a simulated amniotic sac which is made from a male condom filled with 50 ml of water. Experienced obstetricians and fifth-year medical students evaluated satisfaction of the simulator on a scale of 0-10. The medical students evaluated their confidence in performing amniotomy (scale 0-10); immediately after the lecture, immediately after the simulator session, and after completion of the rotation. Results: Nineteen obstetricians rated the simulator with overall satisfaction score of 6.9±1.4 (mean±S.D.) from 10 with lowest satisfactory score of 5.9±2.5 for cervical consistency. One hundred and forty-eight fifth-year medical students were trained for amniotomy during the Health and Diseases of Women rotation throughout the academic year 2012. Each student practised with the simulator on average 2.7±1.3 times. The confidence level for performing amniotomy was 5.3±2.2 after the lecture and markedly improved to 7.9±1.3 after practising with the simulator (p<0.001). Medical students reported the helpfulness score of this simulator during their training on average of 8.3±1.4. Conclusion: The simulator can be used for training medical students in amniotomy. Further modifications should be conducted to improve the satisfaction.https://www.jhsmr.org/index.php/jhsmr/article/view/194amniotomymanikin-based simulatortraining model |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Sirirat Thomrongwat Hatern Tintara |
spellingShingle |
Sirirat Thomrongwat Hatern Tintara Evaluation of a Novel Manikin-Based Amniotomy Simulator Journal of Health Science and Medical Research (JHSMR) amniotomy manikin-based simulator training model |
author_facet |
Sirirat Thomrongwat Hatern Tintara |
author_sort |
Sirirat Thomrongwat |
title |
Evaluation of a Novel Manikin-Based Amniotomy Simulator |
title_short |
Evaluation of a Novel Manikin-Based Amniotomy Simulator |
title_full |
Evaluation of a Novel Manikin-Based Amniotomy Simulator |
title_fullStr |
Evaluation of a Novel Manikin-Based Amniotomy Simulator |
title_full_unstemmed |
Evaluation of a Novel Manikin-Based Amniotomy Simulator |
title_sort |
evaluation of a novel manikin-based amniotomy simulator |
publisher |
Prince of Songkla University |
series |
Journal of Health Science and Medical Research (JHSMR) |
issn |
2586-9981 2630-0559 |
publishDate |
2015-12-01 |
description |
Objective: To evaluate satisfaction of a novel manikin-based amniotomy simulator by obstetricians and medical students.
Material and Methods: The simulator was designed to simulate pregnant women in the active phase of labor with a 3-cm cervical dilatation, 100% effacement, and intact fetal membrane. The simulator consists of an amniotomy box inserted inside a pelvic training model. The front opening of amniotomy box is covered with 1.5-mm thick rubber sheet with a 3-cm diameter central hole. The upper opening is for loading a simulated amniotic sac which is made from a male condom filled with 50 ml of water. Experienced obstetricians and fifth-year medical students evaluated satisfaction of the simulator on a scale of 0-10. The medical students evaluated their confidence in performing amniotomy (scale 0-10); immediately after the lecture, immediately after the simulator session, and after completion of the rotation.
Results: Nineteen obstetricians rated the simulator with overall satisfaction score of 6.9±1.4 (mean±S.D.) from 10 with lowest satisfactory score of 5.9±2.5 for cervical consistency. One hundred and forty-eight fifth-year medical students were trained for amniotomy during the Health and Diseases of Women rotation throughout the academic year 2012. Each student practised with the simulator on average 2.7±1.3 times. The confidence level for performing amniotomy was 5.3±2.2 after the lecture and markedly improved to 7.9±1.3 after practising with the simulator (p<0.001). Medical students reported the helpfulness score of this simulator during their training on average of 8.3±1.4.
Conclusion: The simulator can be used for training medical students in amniotomy. Further modifications should be conducted to improve the satisfaction. |
topic |
amniotomy manikin-based simulator training model |
url |
https://www.jhsmr.org/index.php/jhsmr/article/view/194 |
work_keys_str_mv |
AT siriratthomrongwat evaluationofanovelmanikinbasedamniotomysimulator AT haterntintara evaluationofanovelmanikinbasedamniotomysimulator |
_version_ |
1724850591464685568 |