Measurement Enhancement on Two-Dimensional Temperature Distribution of Methane-Air Premixed Flame Using SMART Algorithm in CT-TDLAS
In this study, the temperature distribution of the Methane-Air premixed flame was measured. In order to enhance the measurement accuracy of the CT-TDLAS (Computed tomography-tunable diode laser absorption spectroscopy), the SMART (simultaneous multiplicative algebraic reconstruction technique) algor...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2019-11-01
|
Series: | Applied Sciences |
Subjects: | |
Online Access: | https://www.mdpi.com/2076-3417/9/22/4955 |
id |
doaj-0696914c519845e8b8420c2ac8be1188 |
---|---|
record_format |
Article |
spelling |
doaj-0696914c519845e8b8420c2ac8be11882020-11-24T23:58:44ZengMDPI AGApplied Sciences2076-34172019-11-01922495510.3390/app9224955app9224955Measurement Enhancement on Two-Dimensional Temperature Distribution of Methane-Air Premixed Flame Using SMART Algorithm in CT-TDLASMin-Gyu Jeon0Deog-Hee Doh1Yoshihiro Deguchi2Division of Mechanical Engineering, Korea Maritime and Ocean University, Busan 49112, KoreaDivision of Mechanical Engineering, Korea Maritime and Ocean University, Busan 49112, KoreaGraduate School of Advanced Technology and Science, Tokushima University, Tokushima 770-8501, JapanIn this study, the temperature distribution of the Methane-Air premixed flame was measured. In order to enhance the measurement accuracy of the CT-TDLAS (Computed tomography-tunable diode laser absorption spectroscopy), the SMART (simultaneous multiplicative algebraic reconstruction technique) algorithm has been adopted. Further, the SLOS (summation of line of sight) and the CSLOS (corrective summation of line of sight) methods have been adopted to increase measurement accuracies. It has been verified that the relative error for the temperatures measured by the thermocouples and calculated by the CT-TDLAS was about 10%.https://www.mdpi.com/2076-3417/9/22/4955methane-air premixed flamecomputed tomography-tunable diode laser absorption spectroscopytemperatureconcentrationburnerexhaust gas |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Min-Gyu Jeon Deog-Hee Doh Yoshihiro Deguchi |
spellingShingle |
Min-Gyu Jeon Deog-Hee Doh Yoshihiro Deguchi Measurement Enhancement on Two-Dimensional Temperature Distribution of Methane-Air Premixed Flame Using SMART Algorithm in CT-TDLAS Applied Sciences methane-air premixed flame computed tomography-tunable diode laser absorption spectroscopy temperature concentration burner exhaust gas |
author_facet |
Min-Gyu Jeon Deog-Hee Doh Yoshihiro Deguchi |
author_sort |
Min-Gyu Jeon |
title |
Measurement Enhancement on Two-Dimensional Temperature Distribution of Methane-Air Premixed Flame Using SMART Algorithm in CT-TDLAS |
title_short |
Measurement Enhancement on Two-Dimensional Temperature Distribution of Methane-Air Premixed Flame Using SMART Algorithm in CT-TDLAS |
title_full |
Measurement Enhancement on Two-Dimensional Temperature Distribution of Methane-Air Premixed Flame Using SMART Algorithm in CT-TDLAS |
title_fullStr |
Measurement Enhancement on Two-Dimensional Temperature Distribution of Methane-Air Premixed Flame Using SMART Algorithm in CT-TDLAS |
title_full_unstemmed |
Measurement Enhancement on Two-Dimensional Temperature Distribution of Methane-Air Premixed Flame Using SMART Algorithm in CT-TDLAS |
title_sort |
measurement enhancement on two-dimensional temperature distribution of methane-air premixed flame using smart algorithm in ct-tdlas |
publisher |
MDPI AG |
series |
Applied Sciences |
issn |
2076-3417 |
publishDate |
2019-11-01 |
description |
In this study, the temperature distribution of the Methane-Air premixed flame was measured. In order to enhance the measurement accuracy of the CT-TDLAS (Computed tomography-tunable diode laser absorption spectroscopy), the SMART (simultaneous multiplicative algebraic reconstruction technique) algorithm has been adopted. Further, the SLOS (summation of line of sight) and the CSLOS (corrective summation of line of sight) methods have been adopted to increase measurement accuracies. It has been verified that the relative error for the temperatures measured by the thermocouples and calculated by the CT-TDLAS was about 10%. |
topic |
methane-air premixed flame computed tomography-tunable diode laser absorption spectroscopy temperature concentration burner exhaust gas |
url |
https://www.mdpi.com/2076-3417/9/22/4955 |
work_keys_str_mv |
AT mingyujeon measurementenhancementontwodimensionaltemperaturedistributionofmethaneairpremixedflameusingsmartalgorithmincttdlas AT deogheedoh measurementenhancementontwodimensionaltemperaturedistributionofmethaneairpremixedflameusingsmartalgorithmincttdlas AT yoshihirodeguchi measurementenhancementontwodimensionaltemperaturedistributionofmethaneairpremixedflameusingsmartalgorithmincttdlas |
_version_ |
1725450006842834944 |