Gas explosion in a room with a window and passage to an adjacent room

Some publications describe an effect, produced during a physical model experiment, when an adjacent gas-free room influences the gas explosion pressure in a room with a window. The explosion pressure in this case significantly exceeds (2.5 times) the explosion pressure in a room without an adjacent...

Full description

Bibliographic Details
Main Authors: Polandov Yuri, Korolchenko Aleksandr, Dobrikov Sergey
Format: Article
Language:English
Published: EDP Sciences 2016-01-01
Series:MATEC Web of Conferences
Online Access:http://dx.doi.org/10.1051/matecconf/20168604031
Description
Summary:Some publications describe an effect, produced during a physical model experiment, when an adjacent gas-free room influences the gas explosion pressure in a room with a window. The explosion pressure in this case significantly exceeds (2.5 times) the explosion pressure in a room without an adjacent room. This result has been confirmed by our studies. Based on other available information about the influence of the ignition point location on the explosion pressure in one room, it was suggested that this could be true for an explosion in two rooms. In our studies we used a test unit with two connected chambers, each having a volume of 1.125 m3. It turned out that this influence of the adjacent volume was not so unambiguous as it was described in those publications. It was found out that the maximum effect of explosion pressure amplification by the adjacent room is achieved, when the igniter is located in the chamber filled with a gas-air mixture in the area between the center of the chamber and the window (maximum amplification by more than 3 times). This effect is lower directly by the window (1.8 times) and is practically absent in case of ignition within the area near the passage connecting the chamber with the adjacent room. This suggests that the effect discovered earlier is a special case of the general dependence of the gas explosion pressure in two chambers on the igniter location.
ISSN:2261-236X