Vibroacoustic technique for the fault diagnosis in a gear transmission of a military helicopter
This article presents the results of laboratory studies of a two-stage gear transmission regarding the process of intentionally increasing damage of its tooth. Also, this study discusses the construction of a gear transmission of a military helicopter on the basis of basic kinematic results of its v...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
JVE International
2017-03-01
|
Series: | Journal of Vibroengineering |
Subjects: | |
Online Access: | https://www.jvejournals.com/article/18401 |
id |
doaj-0659125cda9b4ff6a8486decce925ddb |
---|---|
record_format |
Article |
spelling |
doaj-0659125cda9b4ff6a8486decce925ddb2020-11-24T23:14:16ZengJVE InternationalJournal of Vibroengineering1392-87162538-84602017-03-011921039104910.21595/jve.2017.1840118401Vibroacoustic technique for the fault diagnosis in a gear transmission of a military helicopterMariusz Zieja0Pawel Golda1Mariusz Zokowski2Pawel Majewski3Air Force Institute of Technology, Instytut Techniczny Wojsk Lotniczych, 01-494 Warszawa, ul. Księcia Bolesława 6, PolandAir Force Institute of Technology, Instytut Techniczny Wojsk Lotniczych, 01-494 Warszawa, ul. Księcia Bolesława 6, PolandAir Force Institute of Technology, Instytut Techniczny Wojsk Lotniczych, 01-494 Warszawa, ul. Księcia Bolesława 6, PolandAir Force Institute of Technology, Instytut Techniczny Wojsk Lotniczych, 01-494 Warszawa, ul. Księcia Bolesława 6, PolandThis article presents the results of laboratory studies of a two-stage gear transmission regarding the process of intentionally increasing damage of its tooth. Also, this study discusses the construction of a gear transmission of a military helicopter on the basis of basic kinematic results of its vibroacoustic signals. What is important, the article describes the aim of laboratory stand, which was to authenticate the applied algorithms of technical condition evaluation of combat helicopter. Also, the process of deepening the damage to the tooth of the gear transmission was described. It was made with the use of stable ranges of rotational speed of measurements of transmission casing in three mutually perpendicular directions and have been referred to the condition without damage. In the article, diagnostic criteria are also determined for the assessment of technical conditions of military helicopter equipped with a gear transmission.https://www.jvejournals.com/article/18401gear transmissionvibroacoustics |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Mariusz Zieja Pawel Golda Mariusz Zokowski Pawel Majewski |
spellingShingle |
Mariusz Zieja Pawel Golda Mariusz Zokowski Pawel Majewski Vibroacoustic technique for the fault diagnosis in a gear transmission of a military helicopter Journal of Vibroengineering gear transmission vibroacoustics |
author_facet |
Mariusz Zieja Pawel Golda Mariusz Zokowski Pawel Majewski |
author_sort |
Mariusz Zieja |
title |
Vibroacoustic technique for the fault diagnosis in a gear transmission of a military helicopter |
title_short |
Vibroacoustic technique for the fault diagnosis in a gear transmission of a military helicopter |
title_full |
Vibroacoustic technique for the fault diagnosis in a gear transmission of a military helicopter |
title_fullStr |
Vibroacoustic technique for the fault diagnosis in a gear transmission of a military helicopter |
title_full_unstemmed |
Vibroacoustic technique for the fault diagnosis in a gear transmission of a military helicopter |
title_sort |
vibroacoustic technique for the fault diagnosis in a gear transmission of a military helicopter |
publisher |
JVE International |
series |
Journal of Vibroengineering |
issn |
1392-8716 2538-8460 |
publishDate |
2017-03-01 |
description |
This article presents the results of laboratory studies of a two-stage gear transmission regarding the process of intentionally increasing damage of its tooth. Also, this study discusses the construction of a gear transmission of a military helicopter on the basis of basic kinematic results of its vibroacoustic signals. What is important, the article describes the aim of laboratory stand, which was to authenticate the applied algorithms of technical condition evaluation of combat helicopter. Also, the process of deepening the damage to the tooth of the gear transmission was described. It was made with the use of stable ranges of rotational speed of measurements of transmission casing in three mutually perpendicular directions and have been referred to the condition without damage. In the article, diagnostic criteria are also determined for the assessment of technical conditions of military helicopter equipped with a gear transmission. |
topic |
gear transmission vibroacoustics |
url |
https://www.jvejournals.com/article/18401 |
work_keys_str_mv |
AT mariuszzieja vibroacoustictechniqueforthefaultdiagnosisinageartransmissionofamilitaryhelicopter AT pawelgolda vibroacoustictechniqueforthefaultdiagnosisinageartransmissionofamilitaryhelicopter AT mariuszzokowski vibroacoustictechniqueforthefaultdiagnosisinageartransmissionofamilitaryhelicopter AT pawelmajewski vibroacoustictechniqueforthefaultdiagnosisinageartransmissionofamilitaryhelicopter |
_version_ |
1725595216518316032 |