Comparison of CMM and Micro-CT Volumetric Analysis of Polyethylene Tibial Knee Inserts in Total Knee Replacement
Ultrahigh molecular weight polyethylene (UHMWPE) bearings are used widely in orthopaedic joint replacement as a prominent material for improving the longevity, which is dramatically influenced by wear of polyethylene. Polyethylene tibial knee components from knee simulators under two different input...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi Limited
2018-01-01
|
Series: | International Journal of Polymer Science |
Online Access: | http://dx.doi.org/10.1155/2018/3601480 |
id |
doaj-064bb4aac8ac4cf8a1812e18b248cb9a |
---|---|
record_format |
Article |
spelling |
doaj-064bb4aac8ac4cf8a1812e18b248cb9a2020-11-24T21:44:17ZengHindawi LimitedInternational Journal of Polymer Science1687-94221687-94302018-01-01201810.1155/2018/36014803601480Comparison of CMM and Micro-CT Volumetric Analysis of Polyethylene Tibial Knee Inserts in Total Knee ReplacementWei Jiang0Cuicui Ji1Huaxing Xiao2Zhongmin Jin3Yuntian Dai4School of Mechanical and Automobile Engineering, Changzhou Institute of Technology, Changzhou, Jiangsu 213032, ChinaSchool of Mechanical and Electrical Engineering, Hohai University, Changzhou, Jiangsu 213022, ChinaSchool of Mechanical and Automobile Engineering, Changzhou Institute of Technology, Changzhou, Jiangsu 213032, ChinaLeeds Joint School, Southwest Jiaotong University, Chengdu, Sichuan 611756, ChinaSchool of Mechanical and Automobile Engineering, Changzhou Institute of Technology, Changzhou, Jiangsu 213032, ChinaUltrahigh molecular weight polyethylene (UHMWPE) bearings are used widely in orthopaedic joint replacement as a prominent material for improving the longevity, which is dramatically influenced by wear of polyethylene. Polyethylene tibial knee components from knee simulators under two different input conditions were analyzed using CMM and Micro-CT measurement techniques for volumetric loss with gravimetric measurement as reference. Based on the coordinates and image slices obtained, the surface curve fitting and image digitization methodology were used for the creation of nominal “original” surface in the case of no prewear data provided. The comparison results indicate that gravimetric remains the gold standard and the CMM measurement took less time and had better precision, accuracy, and repeatability compared to Micro-CT measurement technique.http://dx.doi.org/10.1155/2018/3601480 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Wei Jiang Cuicui Ji Huaxing Xiao Zhongmin Jin Yuntian Dai |
spellingShingle |
Wei Jiang Cuicui Ji Huaxing Xiao Zhongmin Jin Yuntian Dai Comparison of CMM and Micro-CT Volumetric Analysis of Polyethylene Tibial Knee Inserts in Total Knee Replacement International Journal of Polymer Science |
author_facet |
Wei Jiang Cuicui Ji Huaxing Xiao Zhongmin Jin Yuntian Dai |
author_sort |
Wei Jiang |
title |
Comparison of CMM and Micro-CT Volumetric Analysis of Polyethylene Tibial Knee Inserts in Total Knee Replacement |
title_short |
Comparison of CMM and Micro-CT Volumetric Analysis of Polyethylene Tibial Knee Inserts in Total Knee Replacement |
title_full |
Comparison of CMM and Micro-CT Volumetric Analysis of Polyethylene Tibial Knee Inserts in Total Knee Replacement |
title_fullStr |
Comparison of CMM and Micro-CT Volumetric Analysis of Polyethylene Tibial Knee Inserts in Total Knee Replacement |
title_full_unstemmed |
Comparison of CMM and Micro-CT Volumetric Analysis of Polyethylene Tibial Knee Inserts in Total Knee Replacement |
title_sort |
comparison of cmm and micro-ct volumetric analysis of polyethylene tibial knee inserts in total knee replacement |
publisher |
Hindawi Limited |
series |
International Journal of Polymer Science |
issn |
1687-9422 1687-9430 |
publishDate |
2018-01-01 |
description |
Ultrahigh molecular weight polyethylene (UHMWPE) bearings are used widely in orthopaedic joint replacement as a prominent material for improving the longevity, which is dramatically influenced by wear of polyethylene. Polyethylene tibial knee components from knee simulators under two different input conditions were analyzed using CMM and Micro-CT measurement techniques for volumetric loss with gravimetric measurement as reference. Based on the coordinates and image slices obtained, the surface curve fitting and image digitization methodology were used for the creation of nominal “original” surface in the case of no prewear data provided. The comparison results indicate that gravimetric remains the gold standard and the CMM measurement took less time and had better precision, accuracy, and repeatability compared to Micro-CT measurement technique. |
url |
http://dx.doi.org/10.1155/2018/3601480 |
work_keys_str_mv |
AT weijiang comparisonofcmmandmicroctvolumetricanalysisofpolyethylenetibialkneeinsertsintotalkneereplacement AT cuicuiji comparisonofcmmandmicroctvolumetricanalysisofpolyethylenetibialkneeinsertsintotalkneereplacement AT huaxingxiao comparisonofcmmandmicroctvolumetricanalysisofpolyethylenetibialkneeinsertsintotalkneereplacement AT zhongminjin comparisonofcmmandmicroctvolumetricanalysisofpolyethylenetibialkneeinsertsintotalkneereplacement AT yuntiandai comparisonofcmmandmicroctvolumetricanalysisofpolyethylenetibialkneeinsertsintotalkneereplacement |
_version_ |
1725911141593382912 |