Prediction of Osteoporosis through Radiographic Assessment of Proximal Femoral Morphology and Texture in Elderly; is it Valid and Reliable

Objective: The purpose of this study was to determine the best predictive radiographic measurement method to identify the presence of osteoporosis and test the inter-observer and intra-observer reliability and validity of these methods in postmenopausal women. Materials and Methods: Ninety-two eld...

Full description

Bibliographic Details
Main Authors: Özkan Köse, Ömer Faruk Kılıçaslan, Hasan Onur Arık, Ümit Sarp, İclal Erdem Toslak, Mehmet Uçar
Format: Article
Language:English
Published: Galenos Yayinevi 2015-08-01
Series:Türk Osteoporoz Dergisi
Subjects:
Online Access:http://www.turkosteoporozdergisi.org/article_8978/Prediction-Of-Osteoporosis-Through-Radiographic-Assessment-Of-Proximal-Femoral-Morphology-And-Texture-In-Elderly-Is-It-Valid-And-Reliable
id doaj-0624874c2a344d63879a3a39775bea6d
record_format Article
spelling doaj-0624874c2a344d63879a3a39775bea6d2020-11-25T03:44:24ZengGalenos YayineviTürk Osteoporoz Dergisi2147-26532015-08-012124652Prediction of Osteoporosis through Radiographic Assessment of Proximal Femoral Morphology and Texture in Elderly; is it Valid and ReliableÖzkan Köse0Ömer Faruk Kılıçaslan1Hasan Onur Arık2Ümit Sarp3İclal Erdem Toslak4Mehmet Uçar5Antalya Education and Research Hospital, Clinic of Orthopedics and Traumatology, Antalya, TurkeyAntalya Education and Research Hospital, Clinic of Orthopedics and Traumatology, Antalya, TurkeyYozgat State Hospital, Clinic of Orthopedics and Traumatology, Yozgat, TurkeyYozgat State Hospital, Clinic of Physical Medicine and Rehabilitation, Yozgat, TurkeyAntalya Education and Research Hospital, Clinic of Radiology, Antalya, TurkeyBozok University Faculty of Medicine, Department of Physical Medicine and Rehabilitation, Yozgat, TurkeyObjective: The purpose of this study was to determine the best predictive radiographic measurement method to identify the presence of osteoporosis and test the inter-observer and intra-observer reliability and validity of these methods in postmenopausal women. Materials and Methods: Ninety-two elderly female patients who presented with hip pain were included. Hip radiographs were used to determine the values of Singh index (SI), canal-to-calcar ratio (CCR), and cortical thickness index (CTI). All measurements were performed by two independent observers on two separate occasions, at least 4 weeks apart. Bone mineral density (BMD) was assessed by DEXA. In the first part of the analysis, reliability of the all measurement methods was tested. In the second part, correlation coefficient (Pearson r) was used to determine the relationship between the measurement methods and BMD. Finally ROC curve analysis was performed to determine the sensitivity, specificity, and threshold values for each radiographic measurement method. Results: Intra-observer reliability analysis of SI revealed kappa coefficient of 0.359 for observer A, and 0.224 for observer B. Inter-observer reliability analysis of SI revealed kappa coefficient of 0.070 for observer A and 0.051 for observer B. The intra-observer and inter-observer reliability was good and excellent for CTI and CCR for both observers (ICC: 0.920 and ICC: 0.936). There was no correlation between SI and BMD (p=0.818). On the other hand, there was a significant correlation between CTI and CCR and BMD (p=0.001). All measured indices were significantly different (p<0.05) between osteoporotic and non-osteoporotic patients. CTI value less than 0.3 or CCR value less than 0.47 reflects the presence of osteoporosis with 100% sensitivity and 98% specificity. Conclusion: SI is not reliable and do not correlate with BMD. However, both CTI and CCR showed good and excellent reliability, and each index correlated well with the real BMD values. (Türk Osteoporoz Dergisi 2015;21: 46-52)http://www.turkosteoporozdergisi.org/article_8978/Prediction-Of-Osteoporosis-Through-Radiographic-Assessment-Of-Proximal-Femoral-Morphology-And-Texture-In-Elderly-Is-It-Valid-And-ReliableOsteoporosispelvis radiographybone mineral densitySingh indexCortical thickness indexcalcar to canal ratio
collection DOAJ
language English
format Article
sources DOAJ
author Özkan Köse
Ömer Faruk Kılıçaslan
Hasan Onur Arık
Ümit Sarp
İclal Erdem Toslak
Mehmet Uçar
spellingShingle Özkan Köse
Ömer Faruk Kılıçaslan
Hasan Onur Arık
Ümit Sarp
İclal Erdem Toslak
Mehmet Uçar
Prediction of Osteoporosis through Radiographic Assessment of Proximal Femoral Morphology and Texture in Elderly; is it Valid and Reliable
Türk Osteoporoz Dergisi
Osteoporosis
pelvis radiography
bone mineral density
Singh index
Cortical thickness index
calcar to canal ratio
author_facet Özkan Köse
Ömer Faruk Kılıçaslan
Hasan Onur Arık
Ümit Sarp
İclal Erdem Toslak
Mehmet Uçar
author_sort Özkan Köse
title Prediction of Osteoporosis through Radiographic Assessment of Proximal Femoral Morphology and Texture in Elderly; is it Valid and Reliable
title_short Prediction of Osteoporosis through Radiographic Assessment of Proximal Femoral Morphology and Texture in Elderly; is it Valid and Reliable
title_full Prediction of Osteoporosis through Radiographic Assessment of Proximal Femoral Morphology and Texture in Elderly; is it Valid and Reliable
title_fullStr Prediction of Osteoporosis through Radiographic Assessment of Proximal Femoral Morphology and Texture in Elderly; is it Valid and Reliable
title_full_unstemmed Prediction of Osteoporosis through Radiographic Assessment of Proximal Femoral Morphology and Texture in Elderly; is it Valid and Reliable
title_sort prediction of osteoporosis through radiographic assessment of proximal femoral morphology and texture in elderly; is it valid and reliable
publisher Galenos Yayinevi
series Türk Osteoporoz Dergisi
issn 2147-2653
publishDate 2015-08-01
description Objective: The purpose of this study was to determine the best predictive radiographic measurement method to identify the presence of osteoporosis and test the inter-observer and intra-observer reliability and validity of these methods in postmenopausal women. Materials and Methods: Ninety-two elderly female patients who presented with hip pain were included. Hip radiographs were used to determine the values of Singh index (SI), canal-to-calcar ratio (CCR), and cortical thickness index (CTI). All measurements were performed by two independent observers on two separate occasions, at least 4 weeks apart. Bone mineral density (BMD) was assessed by DEXA. In the first part of the analysis, reliability of the all measurement methods was tested. In the second part, correlation coefficient (Pearson r) was used to determine the relationship between the measurement methods and BMD. Finally ROC curve analysis was performed to determine the sensitivity, specificity, and threshold values for each radiographic measurement method. Results: Intra-observer reliability analysis of SI revealed kappa coefficient of 0.359 for observer A, and 0.224 for observer B. Inter-observer reliability analysis of SI revealed kappa coefficient of 0.070 for observer A and 0.051 for observer B. The intra-observer and inter-observer reliability was good and excellent for CTI and CCR for both observers (ICC: 0.920 and ICC: 0.936). There was no correlation between SI and BMD (p=0.818). On the other hand, there was a significant correlation between CTI and CCR and BMD (p=0.001). All measured indices were significantly different (p<0.05) between osteoporotic and non-osteoporotic patients. CTI value less than 0.3 or CCR value less than 0.47 reflects the presence of osteoporosis with 100% sensitivity and 98% specificity. Conclusion: SI is not reliable and do not correlate with BMD. However, both CTI and CCR showed good and excellent reliability, and each index correlated well with the real BMD values. (Türk Osteoporoz Dergisi 2015;21: 46-52)
topic Osteoporosis
pelvis radiography
bone mineral density
Singh index
Cortical thickness index
calcar to canal ratio
url http://www.turkosteoporozdergisi.org/article_8978/Prediction-Of-Osteoporosis-Through-Radiographic-Assessment-Of-Proximal-Femoral-Morphology-And-Texture-In-Elderly-Is-It-Valid-And-Reliable
work_keys_str_mv AT ozkankose predictionofosteoporosisthroughradiographicassessmentofproximalfemoralmorphologyandtextureinelderlyisitvalidandreliable
AT omerfarukkılıcaslan predictionofosteoporosisthroughradiographicassessmentofproximalfemoralmorphologyandtextureinelderlyisitvalidandreliable
AT hasanonurarık predictionofosteoporosisthroughradiographicassessmentofproximalfemoralmorphologyandtextureinelderlyisitvalidandreliable
AT umitsarp predictionofosteoporosisthroughradiographicassessmentofproximalfemoralmorphologyandtextureinelderlyisitvalidandreliable
AT iclalerdemtoslak predictionofosteoporosisthroughradiographicassessmentofproximalfemoralmorphologyandtextureinelderlyisitvalidandreliable
AT mehmetucar predictionofosteoporosisthroughradiographicassessmentofproximalfemoralmorphologyandtextureinelderlyisitvalidandreliable
_version_ 1724515236943233024