DETERMINATION OF ANALYTICAL CALCULATION ERROR OF MAGNETIC FIELD OF HIGH-VOLTAGE CABLE LINES WITH TWO-POINT BONDED CABLE SHIELDS CAUSED BY NON-UNIFORM CURRENT DISTRIBUTION IN THE SHIELDS

Purpose. To obtain new calculation correlations, determining approximate energy dissipation and electric erosion of massive basic metallic electrodes in the high-voltage high-current air switchboard (HVCAS) of atmospheric pressure, in-use in the bit chain of the high-voltage electrophysics setting (...

Full description

Bibliographic Details
Main Authors: M. I. Baranov, S. V. Rudakov
Format: Article
Language:English
Published: National Technical University "Kharkiv Polytechnic Institute" 2017-06-01
Series:Електротехніка і електромеханіка
Subjects:
Online Access:http://eie.khpi.edu.ua/article/view/2074-272X.2017.3.05/100688
id doaj-0616f56c04cf46c9a46365cde21cb0d4
record_format Article
spelling doaj-0616f56c04cf46c9a46365cde21cb0d42021-07-02T01:42:52ZengNational Technical University "Kharkiv Polytechnic Institute"Електротехніка і електромеханіка2074-272X2309-34042017-06-013323910.20998/2074-272X.2017.3.05DETERMINATION OF ANALYTICAL CALCULATION ERROR OF MAGNETIC FIELD OF HIGH-VOLTAGE CABLE LINES WITH TWO-POINT BONDED CABLE SHIELDS CAUSED BY NON-UNIFORM CURRENT DISTRIBUTION IN THE SHIELDSM. I. Baranov0S. V. Rudakov1National Technical University «Kharkiv Polytechnic Institute»National University of Civil Protection of Ukraine Purpose. To obtain new calculation correlations, determining approximate energy dissipation and electric erosion of massive basic metallic electrodes in the high-voltage high-current air switchboard (HVCAS) of atmospheric pressure, in-use in the bit chain of the high-voltage electrophysics setting (HVES) with the powerful capacity store of energy (CSE). Methodology. Electrophysics bases of technique of high-voltage and large impulsive currents (LIC), scientific and technical bases of development and planning of high-voltage heavy-current impulsive electro-devices, including HVES and powerful CSE, and also methods of measuring in their bit chains of LIC of the microsecond temporal range. Results. On the basis of new engineering approach the results of calculation estimation of excretions energy and electric erosion of massive basic metallic electrodes are resulted in probed HVCAS. New correlations are obtained for the approximate calculation of thermal energy, selected in an impulsive air spark and on the workings surfaces of anode and cathode of HVCAS. It is entered and a new electrophysics concept, touching equivalent active resistance of impulsive air spark, is mathematically certain. New formulas are obtained for the approximate calculation of most depth of single round crater of destruction on the workings surfaces of basic metallic electrodes of HVCAS, and also mass of metal, thrown out magnetic pressure from this crater of destruction on the electrodes of switch for one electric discharge through them powerful CSE HVES. It is shown that the radius of the indicated single crater of destruction is approximately equal to the maximal radius of plasma channel of a spark discharge between a cathode and anode of HVCAS. The executed high-current experiments in the bit chain of HVES with powerful CSE validated row of the got and in-use calculation correlations for the estimation of energy dissipation and electric erosion of metallic electrodes in examined HVCAS. Originality. New engineering approach is developed for the approximate calculation and estimation of energy dissipation and electric erosion of basic metallic electrodes in HVCAS. A formula is firstly got for approximate calculation unchanging in the process of swaying or aperiodic discharge of CSE HVES on the electric loading of active resistance of impulsive air spark between the electrodes of probed HVCAS. Practical value. Drawing on the got results in a high-voltage impulsive technique provides operative implementation of calculation of balance of electric energy in the high-current circuit of HVES with powerful CSE and point electric load, and also prognostication of the technical state of workings surfaces of massive basic metallic electrodes of HVCAS. http://eie.khpi.edu.ua/article/view/2074-272X.2017.3.05/100688high-voltage high-current air switchdissipated thermal energy in air spark and on the electrodes of switchelectric erosion of metallic electrodes of switchdepth of single crater of destruction on the electrodes of switchthrown out mass of metal from the single crater of destruction of electrodes of switch
collection DOAJ
language English
format Article
sources DOAJ
author M. I. Baranov
S. V. Rudakov
spellingShingle M. I. Baranov
S. V. Rudakov
DETERMINATION OF ANALYTICAL CALCULATION ERROR OF MAGNETIC FIELD OF HIGH-VOLTAGE CABLE LINES WITH TWO-POINT BONDED CABLE SHIELDS CAUSED BY NON-UNIFORM CURRENT DISTRIBUTION IN THE SHIELDS
Електротехніка і електромеханіка
high-voltage high-current air switch
dissipated thermal energy in air spark and on the electrodes of switch
electric erosion of metallic electrodes of switch
depth of single crater of destruction on the electrodes of switch
thrown out mass of metal from the single crater of destruction of electrodes of switch
author_facet M. I. Baranov
S. V. Rudakov
author_sort M. I. Baranov
title DETERMINATION OF ANALYTICAL CALCULATION ERROR OF MAGNETIC FIELD OF HIGH-VOLTAGE CABLE LINES WITH TWO-POINT BONDED CABLE SHIELDS CAUSED BY NON-UNIFORM CURRENT DISTRIBUTION IN THE SHIELDS
title_short DETERMINATION OF ANALYTICAL CALCULATION ERROR OF MAGNETIC FIELD OF HIGH-VOLTAGE CABLE LINES WITH TWO-POINT BONDED CABLE SHIELDS CAUSED BY NON-UNIFORM CURRENT DISTRIBUTION IN THE SHIELDS
title_full DETERMINATION OF ANALYTICAL CALCULATION ERROR OF MAGNETIC FIELD OF HIGH-VOLTAGE CABLE LINES WITH TWO-POINT BONDED CABLE SHIELDS CAUSED BY NON-UNIFORM CURRENT DISTRIBUTION IN THE SHIELDS
title_fullStr DETERMINATION OF ANALYTICAL CALCULATION ERROR OF MAGNETIC FIELD OF HIGH-VOLTAGE CABLE LINES WITH TWO-POINT BONDED CABLE SHIELDS CAUSED BY NON-UNIFORM CURRENT DISTRIBUTION IN THE SHIELDS
title_full_unstemmed DETERMINATION OF ANALYTICAL CALCULATION ERROR OF MAGNETIC FIELD OF HIGH-VOLTAGE CABLE LINES WITH TWO-POINT BONDED CABLE SHIELDS CAUSED BY NON-UNIFORM CURRENT DISTRIBUTION IN THE SHIELDS
title_sort determination of analytical calculation error of magnetic field of high-voltage cable lines with two-point bonded cable shields caused by non-uniform current distribution in the shields
publisher National Technical University "Kharkiv Polytechnic Institute"
series Електротехніка і електромеханіка
issn 2074-272X
2309-3404
publishDate 2017-06-01
description Purpose. To obtain new calculation correlations, determining approximate energy dissipation and electric erosion of massive basic metallic electrodes in the high-voltage high-current air switchboard (HVCAS) of atmospheric pressure, in-use in the bit chain of the high-voltage electrophysics setting (HVES) with the powerful capacity store of energy (CSE). Methodology. Electrophysics bases of technique of high-voltage and large impulsive currents (LIC), scientific and technical bases of development and planning of high-voltage heavy-current impulsive electro-devices, including HVES and powerful CSE, and also methods of measuring in their bit chains of LIC of the microsecond temporal range. Results. On the basis of new engineering approach the results of calculation estimation of excretions energy and electric erosion of massive basic metallic electrodes are resulted in probed HVCAS. New correlations are obtained for the approximate calculation of thermal energy, selected in an impulsive air spark and on the workings surfaces of anode and cathode of HVCAS. It is entered and a new electrophysics concept, touching equivalent active resistance of impulsive air spark, is mathematically certain. New formulas are obtained for the approximate calculation of most depth of single round crater of destruction on the workings surfaces of basic metallic electrodes of HVCAS, and also mass of metal, thrown out magnetic pressure from this crater of destruction on the electrodes of switch for one electric discharge through them powerful CSE HVES. It is shown that the radius of the indicated single crater of destruction is approximately equal to the maximal radius of plasma channel of a spark discharge between a cathode and anode of HVCAS. The executed high-current experiments in the bit chain of HVES with powerful CSE validated row of the got and in-use calculation correlations for the estimation of energy dissipation and electric erosion of metallic electrodes in examined HVCAS. Originality. New engineering approach is developed for the approximate calculation and estimation of energy dissipation and electric erosion of basic metallic electrodes in HVCAS. A formula is firstly got for approximate calculation unchanging in the process of swaying or aperiodic discharge of CSE HVES on the electric loading of active resistance of impulsive air spark between the electrodes of probed HVCAS. Practical value. Drawing on the got results in a high-voltage impulsive technique provides operative implementation of calculation of balance of electric energy in the high-current circuit of HVES with powerful CSE and point electric load, and also prognostication of the technical state of workings surfaces of massive basic metallic electrodes of HVCAS.
topic high-voltage high-current air switch
dissipated thermal energy in air spark and on the electrodes of switch
electric erosion of metallic electrodes of switch
depth of single crater of destruction on the electrodes of switch
thrown out mass of metal from the single crater of destruction of electrodes of switch
url http://eie.khpi.edu.ua/article/view/2074-272X.2017.3.05/100688
work_keys_str_mv AT mibaranov determinationofanalyticalcalculationerrorofmagneticfieldofhighvoltagecablelineswithtwopointbondedcableshieldscausedbynonuniformcurrentdistributionintheshields
AT svrudakov determinationofanalyticalcalculationerrorofmagneticfieldofhighvoltagecablelineswithtwopointbondedcableshieldscausedbynonuniformcurrentdistributionintheshields
_version_ 1721344461852639232