Incipient Fault Location Method of Cable Based on Both-End Electric Quantities

The early fault of a cable is usually a incipient fault, which is difficult to find and can easily develop into an insulation breakdown fault. Thus, it is of great significance to quickly and accurately find an incipient cable fault. This paper presents an fault location method for cable insulation...

Full description

Bibliographic Details
Main Authors: Wenxia Pan, Ye Li, Kai Sun, Zhu Zhu, Xinrui Li
Format: Article
Language:English
Published: IEEE 2020-01-01
Series:IEEE Access
Subjects:
Online Access:https://ieeexplore.ieee.org/document/9281304/
id doaj-057215f21d0b436084f8a74e6cfd4fbd
record_format Article
spelling doaj-057215f21d0b436084f8a74e6cfd4fbd2021-05-19T23:03:06ZengIEEEIEEE Access2169-35362020-01-01821950321951210.1109/ACCESS.2020.30425579281304Incipient Fault Location Method of Cable Based on Both-End Electric QuantitiesWenxia Pan0https://orcid.org/0000-0003-4353-7329Ye Li1https://orcid.org/0000-0002-6916-8974Kai Sun2https://orcid.org/0000-0001-8820-4005Zhu Zhu3https://orcid.org/0000-0003-4588-4922Xinrui Li4https://orcid.org/0000-0001-5965-3733College of Energy and Electrical Engineering, Hohai University, Nanjing, ChinaCollege of Energy and Electrical Engineering, Hohai University, Nanjing, ChinaHuai’an Power Supply Branch, State Grid Jiangsu Electric Power Company, Huai’an, ChinaCollege of Energy and Electrical Engineering, Hohai University, Nanjing, ChinaCollege of Energy and Electrical Engineering, Hohai University, Nanjing, ChinaThe early fault of a cable is usually a incipient fault, which is difficult to find and can easily develop into an insulation breakdown fault. Thus, it is of great significance to quickly and accurately find an incipient cable fault. This paper presents an fault location method for cable insulation based on the electric quantities of both ends. Based on the equivalent circuit model of three-phase single-core cable distribution parameters, the calculation method of the voltage along the cable is derived. The equivalent model of cable insulation in resistive and capacitive parallel is proposed and applied to the early fault modeling of cable. On the basis of the calculation formula of the voltage along the cable and the electric quantity at both ends of the cable, the analytical expression of the cable fault location is obtained by solving the fault equation directly. Extensive simulations show that the algorithm, this method can locate the incipient fault accurately, and is not affected by the fault point, fault resistance and fault inception angle.https://ieeexplore.ieee.org/document/9281304/Cable insulationfault locationdistributed parametersequivalent modelsheath current
collection DOAJ
language English
format Article
sources DOAJ
author Wenxia Pan
Ye Li
Kai Sun
Zhu Zhu
Xinrui Li
spellingShingle Wenxia Pan
Ye Li
Kai Sun
Zhu Zhu
Xinrui Li
Incipient Fault Location Method of Cable Based on Both-End Electric Quantities
IEEE Access
Cable insulation
fault location
distributed parameters
equivalent model
sheath current
author_facet Wenxia Pan
Ye Li
Kai Sun
Zhu Zhu
Xinrui Li
author_sort Wenxia Pan
title Incipient Fault Location Method of Cable Based on Both-End Electric Quantities
title_short Incipient Fault Location Method of Cable Based on Both-End Electric Quantities
title_full Incipient Fault Location Method of Cable Based on Both-End Electric Quantities
title_fullStr Incipient Fault Location Method of Cable Based on Both-End Electric Quantities
title_full_unstemmed Incipient Fault Location Method of Cable Based on Both-End Electric Quantities
title_sort incipient fault location method of cable based on both-end electric quantities
publisher IEEE
series IEEE Access
issn 2169-3536
publishDate 2020-01-01
description The early fault of a cable is usually a incipient fault, which is difficult to find and can easily develop into an insulation breakdown fault. Thus, it is of great significance to quickly and accurately find an incipient cable fault. This paper presents an fault location method for cable insulation based on the electric quantities of both ends. Based on the equivalent circuit model of three-phase single-core cable distribution parameters, the calculation method of the voltage along the cable is derived. The equivalent model of cable insulation in resistive and capacitive parallel is proposed and applied to the early fault modeling of cable. On the basis of the calculation formula of the voltage along the cable and the electric quantity at both ends of the cable, the analytical expression of the cable fault location is obtained by solving the fault equation directly. Extensive simulations show that the algorithm, this method can locate the incipient fault accurately, and is not affected by the fault point, fault resistance and fault inception angle.
topic Cable insulation
fault location
distributed parameters
equivalent model
sheath current
url https://ieeexplore.ieee.org/document/9281304/
work_keys_str_mv AT wenxiapan incipientfaultlocationmethodofcablebasedonbothendelectricquantities
AT yeli incipientfaultlocationmethodofcablebasedonbothendelectricquantities
AT kaisun incipientfaultlocationmethodofcablebasedonbothendelectricquantities
AT zhuzhu incipientfaultlocationmethodofcablebasedonbothendelectricquantities
AT xinruili incipientfaultlocationmethodofcablebasedonbothendelectricquantities
_version_ 1721436077633306624