Incipient Fault Location Method of Cable Based on Both-End Electric Quantities
The early fault of a cable is usually a incipient fault, which is difficult to find and can easily develop into an insulation breakdown fault. Thus, it is of great significance to quickly and accurately find an incipient cable fault. This paper presents an fault location method for cable insulation...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
IEEE
2020-01-01
|
Series: | IEEE Access |
Subjects: | |
Online Access: | https://ieeexplore.ieee.org/document/9281304/ |
id |
doaj-057215f21d0b436084f8a74e6cfd4fbd |
---|---|
record_format |
Article |
spelling |
doaj-057215f21d0b436084f8a74e6cfd4fbd2021-05-19T23:03:06ZengIEEEIEEE Access2169-35362020-01-01821950321951210.1109/ACCESS.2020.30425579281304Incipient Fault Location Method of Cable Based on Both-End Electric QuantitiesWenxia Pan0https://orcid.org/0000-0003-4353-7329Ye Li1https://orcid.org/0000-0002-6916-8974Kai Sun2https://orcid.org/0000-0001-8820-4005Zhu Zhu3https://orcid.org/0000-0003-4588-4922Xinrui Li4https://orcid.org/0000-0001-5965-3733College of Energy and Electrical Engineering, Hohai University, Nanjing, ChinaCollege of Energy and Electrical Engineering, Hohai University, Nanjing, ChinaHuai’an Power Supply Branch, State Grid Jiangsu Electric Power Company, Huai’an, ChinaCollege of Energy and Electrical Engineering, Hohai University, Nanjing, ChinaCollege of Energy and Electrical Engineering, Hohai University, Nanjing, ChinaThe early fault of a cable is usually a incipient fault, which is difficult to find and can easily develop into an insulation breakdown fault. Thus, it is of great significance to quickly and accurately find an incipient cable fault. This paper presents an fault location method for cable insulation based on the electric quantities of both ends. Based on the equivalent circuit model of three-phase single-core cable distribution parameters, the calculation method of the voltage along the cable is derived. The equivalent model of cable insulation in resistive and capacitive parallel is proposed and applied to the early fault modeling of cable. On the basis of the calculation formula of the voltage along the cable and the electric quantity at both ends of the cable, the analytical expression of the cable fault location is obtained by solving the fault equation directly. Extensive simulations show that the algorithm, this method can locate the incipient fault accurately, and is not affected by the fault point, fault resistance and fault inception angle.https://ieeexplore.ieee.org/document/9281304/Cable insulationfault locationdistributed parametersequivalent modelsheath current |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Wenxia Pan Ye Li Kai Sun Zhu Zhu Xinrui Li |
spellingShingle |
Wenxia Pan Ye Li Kai Sun Zhu Zhu Xinrui Li Incipient Fault Location Method of Cable Based on Both-End Electric Quantities IEEE Access Cable insulation fault location distributed parameters equivalent model sheath current |
author_facet |
Wenxia Pan Ye Li Kai Sun Zhu Zhu Xinrui Li |
author_sort |
Wenxia Pan |
title |
Incipient Fault Location Method of Cable Based on Both-End Electric Quantities |
title_short |
Incipient Fault Location Method of Cable Based on Both-End Electric Quantities |
title_full |
Incipient Fault Location Method of Cable Based on Both-End Electric Quantities |
title_fullStr |
Incipient Fault Location Method of Cable Based on Both-End Electric Quantities |
title_full_unstemmed |
Incipient Fault Location Method of Cable Based on Both-End Electric Quantities |
title_sort |
incipient fault location method of cable based on both-end electric quantities |
publisher |
IEEE |
series |
IEEE Access |
issn |
2169-3536 |
publishDate |
2020-01-01 |
description |
The early fault of a cable is usually a incipient fault, which is difficult to find and can easily develop into an insulation breakdown fault. Thus, it is of great significance to quickly and accurately find an incipient cable fault. This paper presents an fault location method for cable insulation based on the electric quantities of both ends. Based on the equivalent circuit model of three-phase single-core cable distribution parameters, the calculation method of the voltage along the cable is derived. The equivalent model of cable insulation in resistive and capacitive parallel is proposed and applied to the early fault modeling of cable. On the basis of the calculation formula of the voltage along the cable and the electric quantity at both ends of the cable, the analytical expression of the cable fault location is obtained by solving the fault equation directly. Extensive simulations show that the algorithm, this method can locate the incipient fault accurately, and is not affected by the fault point, fault resistance and fault inception angle. |
topic |
Cable insulation fault location distributed parameters equivalent model sheath current |
url |
https://ieeexplore.ieee.org/document/9281304/ |
work_keys_str_mv |
AT wenxiapan incipientfaultlocationmethodofcablebasedonbothendelectricquantities AT yeli incipientfaultlocationmethodofcablebasedonbothendelectricquantities AT kaisun incipientfaultlocationmethodofcablebasedonbothendelectricquantities AT zhuzhu incipientfaultlocationmethodofcablebasedonbothendelectricquantities AT xinruili incipientfaultlocationmethodofcablebasedonbothendelectricquantities |