Characterization of Elastic and Plastic Behaviors in Steel Plate Based on Eddy Current Technique Using a Portable Impedance Analyzer
A portable impedance analyzer (PIA) was developed based on a TiePie-HS3 device to provide the comparable impedance measurement accuracy of the Agilent 4294a impedance analyzer in the frequency range of 0~250 kHz. Then the PIA was applied to monitor the tensile stress-induced variation of the eddy cu...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi Limited
2017-01-01
|
Series: | Journal of Sensors |
Online Access: | http://dx.doi.org/10.1155/2017/8424012 |
id |
doaj-0539abb68a914d96adf377e07e52beeb |
---|---|
record_format |
Article |
spelling |
doaj-0539abb68a914d96adf377e07e52beeb2020-11-25T02:27:45ZengHindawi LimitedJournal of Sensors1687-725X1687-72682017-01-01201710.1155/2017/84240128424012Characterization of Elastic and Plastic Behaviors in Steel Plate Based on Eddy Current Technique Using a Portable Impedance AnalyzerMeng Fanlin0Liu Xiucheng1Wang Heyun2He Cunfu3Wu Bin4College of Mechanical Engineering and Applied Electronics Technology, Beijing University of Technology, Beijing, ChinaCollege of Mechanical Engineering and Applied Electronics Technology, Beijing University of Technology, Beijing, ChinaCollege of Mechanical Engineering and Applied Electronics Technology, Beijing University of Technology, Beijing, ChinaCollege of Mechanical Engineering and Applied Electronics Technology, Beijing University of Technology, Beijing, ChinaCollege of Mechanical Engineering and Applied Electronics Technology, Beijing University of Technology, Beijing, ChinaA portable impedance analyzer (PIA) was developed based on a TiePie-HS3 device to provide the comparable impedance measurement accuracy of the Agilent 4294a impedance analyzer in the frequency range of 0~250 kHz. Then the PIA was applied to monitor the tensile stress-induced variation of the eddy current sensor’s impedance in a medium-carbon steel sample. A model of equivalent magnetic field induced by the elastic stress and the number of pinning sites indicated that the inductance of the eddy current loop firstly increased with the increase in the tensile stress and then decreased at the yield point of the material. The experimental results testified that the variation of impedance amplitude, the variation of phase angle, and the shift of two featured frequencies demonstrated opposite variation trends before and after the yield point, as predicated by the model. A new parameter, which combined the impedance variation information of the selected two frequencies, was found to exhibit nearly monotonous dependency on the tensile stress in elastic and plastic stages. The new parameter together with the developed portable impedance analyzer provided the solution to identify the elastic and plastic behaviors in ferromagnetic materials in practical applications with an eddy current technique.http://dx.doi.org/10.1155/2017/8424012 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Meng Fanlin Liu Xiucheng Wang Heyun He Cunfu Wu Bin |
spellingShingle |
Meng Fanlin Liu Xiucheng Wang Heyun He Cunfu Wu Bin Characterization of Elastic and Plastic Behaviors in Steel Plate Based on Eddy Current Technique Using a Portable Impedance Analyzer Journal of Sensors |
author_facet |
Meng Fanlin Liu Xiucheng Wang Heyun He Cunfu Wu Bin |
author_sort |
Meng Fanlin |
title |
Characterization of Elastic and Plastic Behaviors in Steel Plate Based on Eddy Current Technique Using a Portable Impedance Analyzer |
title_short |
Characterization of Elastic and Plastic Behaviors in Steel Plate Based on Eddy Current Technique Using a Portable Impedance Analyzer |
title_full |
Characterization of Elastic and Plastic Behaviors in Steel Plate Based on Eddy Current Technique Using a Portable Impedance Analyzer |
title_fullStr |
Characterization of Elastic and Plastic Behaviors in Steel Plate Based on Eddy Current Technique Using a Portable Impedance Analyzer |
title_full_unstemmed |
Characterization of Elastic and Plastic Behaviors in Steel Plate Based on Eddy Current Technique Using a Portable Impedance Analyzer |
title_sort |
characterization of elastic and plastic behaviors in steel plate based on eddy current technique using a portable impedance analyzer |
publisher |
Hindawi Limited |
series |
Journal of Sensors |
issn |
1687-725X 1687-7268 |
publishDate |
2017-01-01 |
description |
A portable impedance analyzer (PIA) was developed based on a TiePie-HS3 device to provide the comparable impedance measurement accuracy of the Agilent 4294a impedance analyzer in the frequency range of 0~250 kHz. Then the PIA was applied to monitor the tensile stress-induced variation of the eddy current sensor’s impedance in a medium-carbon steel sample. A model of equivalent magnetic field induced by the elastic stress and the number of pinning sites indicated that the inductance of the eddy current loop firstly increased with the increase in the tensile stress and then decreased at the yield point of the material. The experimental results testified that the variation of impedance amplitude, the variation of phase angle, and the shift of two featured frequencies demonstrated opposite variation trends before and after the yield point, as predicated by the model. A new parameter, which combined the impedance variation information of the selected two frequencies, was found to exhibit nearly monotonous dependency on the tensile stress in elastic and plastic stages. The new parameter together with the developed portable impedance analyzer provided the solution to identify the elastic and plastic behaviors in ferromagnetic materials in practical applications with an eddy current technique. |
url |
http://dx.doi.org/10.1155/2017/8424012 |
work_keys_str_mv |
AT mengfanlin characterizationofelasticandplasticbehaviorsinsteelplatebasedoneddycurrenttechniqueusingaportableimpedanceanalyzer AT liuxiucheng characterizationofelasticandplasticbehaviorsinsteelplatebasedoneddycurrenttechniqueusingaportableimpedanceanalyzer AT wangheyun characterizationofelasticandplasticbehaviorsinsteelplatebasedoneddycurrenttechniqueusingaportableimpedanceanalyzer AT hecunfu characterizationofelasticandplasticbehaviorsinsteelplatebasedoneddycurrenttechniqueusingaportableimpedanceanalyzer AT wubin characterizationofelasticandplasticbehaviorsinsteelplatebasedoneddycurrenttechniqueusingaportableimpedanceanalyzer |
_version_ |
1724840942773469184 |